Mechanical properties of human bone-implant interface tissue in aseptically loose hip implants

被引:21
|
作者
Kraaij, Gert [1 ,2 ,3 ]
Zadpoor, Amir A. [2 ]
Tuijthof, Gabrielle J. M. [1 ,2 ,3 ]
Dankelman, Jenny [2 ]
Nelissen, Rob G. H. H. [1 ,3 ]
Valstar, Edward R. [1 ,2 ,3 ]
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, Biomech & Imaging Grp, NL-2300 RC Leiden, Netherlands
[2] Delft Univ Technol, Dept Biomech Engn, NL-2628 CD Delft, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Orthoped Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
Hip; Prosthesis; Loosening; Interface membrane; Biomechanics; SOFT BIOLOGICAL TISSUES; SYNOVIAL-LIKE MEMBRANE; CEMENT INTERFACE; BRAIN-TISSUE; UNCONFINED COMPRESSION; ABDOMINAL ORGANS; IN-VITRO; KIDNEY; ARTHROPLASTY; REPLACEMENT;
D O I
10.1016/j.jmbbm.2014.06.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main cause of failure in total hip replacement is aseptic loosening which is associated with the formation of a periprosthetic fibrous (interface) tissue. Despite important applications for finite element modeling of loose implants, the mechanical properties of the bone implant interface tissue have never been measured in humans. In this study, we performed unconfined compression tests to characterize the mechanical properties of the interface tissue and to determine the parameters of various hyperelastic material models which were fitted to the measurements. Human interface tissues were retrieved during 21 elective revision surgeries from aseptically loosened cemented (N=10) and uncemented hip implants (N=11). Specimens were tested at a fixed deformation rate of 0.1 mm/min up to a maximum force of 10 N. Elastic moduli for low and high strain regions of the stress strain curves were determined. Interface tissue from aseptically loose cemented prostheses shows higher elastic moduli (mean=1.85 MPa, 95% C.I.=1.76-1.95 MPa) in the high strain region as compared to that of the interface tissue from the cementless group (mean=1.65 MPa, 95% C.I.=1.43-1.88 MPa). The 5-terms Mooney Rivlin model (W = C-1[I-1 - 3] + C-2[I-2 - 3] + C-3[I-1 - 3][I-2 - 3] + C-4[I-1 - 3](2) + C-5[I-2 - 3](2)) described the stress strain behavior the best. Large variations in the mechanical behavior were observed both between specimens from the same patient as between those of different patients. The material model parameters were therefore estimated for the mean data as well as for the curves with the highest and lowest strain at the maximum load. The model parameters found for the mean data were C-1=-0.0074 MPa, C-2=0.0019 MPa, C-3=0 MPa, C-4=0.0032 MPa and C-5=0 MPa in the cemented group and C-1=0.0137 MPa, C-2=0.0069 MPa, C-3=0.0026 MPa, C-4=-0.0094 MPa and C-5=0 MPa in the cementless group. The results of this study can be used in finite element computer. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [11] Strontium in the Bone-Implant Interface
    Vestermark, Marianne Toft
    DANISH MEDICAL BULLETIN, 2011, 58 (05)
  • [12] Engineering the Bone-Implant Interface
    Mangano, Francesco
    Maghaireh, Hassan
    Calvo-Guirado, Jose
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [13] The bone-implant interface - nanoscale analysis of clinically retrieved dental implants
    Shah, Furqan Ali
    Nilson, Bengt
    Branemark, Rickard
    Thomsen, Peter
    Palmquist, Anders
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2014, 10 (08) : 1729 - 1737
  • [14] BONE-IMPLANT INTERFACE CHARACTERISTICS
    ALBREKTSSON, T
    ALBREKTSSON, B
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (06): : 715 - 717
  • [15] Messenger ribonucleic acid expression of 16 matrix metalloproteinases in bone-implant interface tissues of loose artificial hip joints
    Takei, I
    Takagi, M
    Santavirta, S
    Ida, H
    Ishii, M
    Ogino, T
    Ainola, M
    Konttinen, YT
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 52 (04): : 613 - 620
  • [16] Percutaneous bone cement refixation of aseptically loose hip prostheses: the effect of interface tissue removal on injected cement volumes
    Daniël F. Malan
    Edward R. Valstar
    Rob G. H. H. Nelissen
    Skeletal Radiology, 2014, 43 : 1537 - 1542
  • [17] Proteoglycans at the bone-implant interface
    Klinger, MM
    Rahemtulla, F
    Prince, CW
    Lucas, LC
    Lemons, JE
    CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 1998, 9 (04) : 449 - 463
  • [18] Percutaneous bone cement refixation of aseptically loose hip prostheses: the effect of interface tissue removal on injected cement volumes
    Malan, Daniel F.
    Valstar, Edward R.
    Nelissen, Rob G. H. H.
    SKELETAL RADIOLOGY, 2014, 43 (11) : 1537 - 1542
  • [19] Apoptosis in interface membranes of aseptically loose total hip arthroplasty
    Huk, OL
    Zukor, DJ
    Ralston, W
    Lisbona, A
    Petit, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (07) : 653 - 658
  • [20] Apoptosis in interface membranes of aseptically loose total hip arthroplasty
    Olga L. Huk
    David J. Zukor
    Whitney Ralston
    Allan Lisbona
    Alain Petit
    Journal of Materials Science: Materials in Medicine, 2001, 12 : 653 - 658