Mechanical properties of human bone-implant interface tissue in aseptically loose hip implants

被引:21
|
作者
Kraaij, Gert [1 ,2 ,3 ]
Zadpoor, Amir A. [2 ]
Tuijthof, Gabrielle J. M. [1 ,2 ,3 ]
Dankelman, Jenny [2 ]
Nelissen, Rob G. H. H. [1 ,3 ]
Valstar, Edward R. [1 ,2 ,3 ]
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, Biomech & Imaging Grp, NL-2300 RC Leiden, Netherlands
[2] Delft Univ Technol, Dept Biomech Engn, NL-2628 CD Delft, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Orthoped Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
Hip; Prosthesis; Loosening; Interface membrane; Biomechanics; SOFT BIOLOGICAL TISSUES; SYNOVIAL-LIKE MEMBRANE; CEMENT INTERFACE; BRAIN-TISSUE; UNCONFINED COMPRESSION; ABDOMINAL ORGANS; IN-VITRO; KIDNEY; ARTHROPLASTY; REPLACEMENT;
D O I
10.1016/j.jmbbm.2014.06.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main cause of failure in total hip replacement is aseptic loosening which is associated with the formation of a periprosthetic fibrous (interface) tissue. Despite important applications for finite element modeling of loose implants, the mechanical properties of the bone implant interface tissue have never been measured in humans. In this study, we performed unconfined compression tests to characterize the mechanical properties of the interface tissue and to determine the parameters of various hyperelastic material models which were fitted to the measurements. Human interface tissues were retrieved during 21 elective revision surgeries from aseptically loosened cemented (N=10) and uncemented hip implants (N=11). Specimens were tested at a fixed deformation rate of 0.1 mm/min up to a maximum force of 10 N. Elastic moduli for low and high strain regions of the stress strain curves were determined. Interface tissue from aseptically loose cemented prostheses shows higher elastic moduli (mean=1.85 MPa, 95% C.I.=1.76-1.95 MPa) in the high strain region as compared to that of the interface tissue from the cementless group (mean=1.65 MPa, 95% C.I.=1.43-1.88 MPa). The 5-terms Mooney Rivlin model (W = C-1[I-1 - 3] + C-2[I-2 - 3] + C-3[I-1 - 3][I-2 - 3] + C-4[I-1 - 3](2) + C-5[I-2 - 3](2)) described the stress strain behavior the best. Large variations in the mechanical behavior were observed both between specimens from the same patient as between those of different patients. The material model parameters were therefore estimated for the mean data as well as for the curves with the highest and lowest strain at the maximum load. The model parameters found for the mean data were C-1=-0.0074 MPa, C-2=0.0019 MPa, C-3=0 MPa, C-4=0.0032 MPa and C-5=0 MPa in the cemented group and C-1=0.0137 MPa, C-2=0.0069 MPa, C-3=0.0026 MPa, C-4=-0.0094 MPa and C-5=0 MPa in the cementless group. The results of this study can be used in finite element computer. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [1] Simultaneous labeling of mast cell proteases and protease mRNAs at the bone-implant interface of aseptically loosened hip implants
    Qiu, J
    Beckman, MJ
    Qian, J
    Jiranek, W
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) : 942 - 948
  • [2] Production of matrix metalloproteinases at the bone-implant interface in loose total hip replacements
    Yokohama, Y
    Matsumoto, T
    Hirakawa, M
    Kuroki, Y
    Fujimoto, N
    Imai, K
    Okada, Y
    LABORATORY INVESTIGATION, 1995, 73 (06) : 899 - 911
  • [3] Biomechanical determinants of the stability of dental implants: Influence of the bone-implant interface properties
    Mathieu, Vincent
    Vayron, Romain
    Richard, Gilles
    Lambert, Gregory
    Naili, Salah
    Meningaud, Jean-Paul
    Haiat, Guillaume
    JOURNAL OF BIOMECHANICS, 2014, 47 (01) : 3 - 13
  • [4] Lymphangiogenesis in the bone-implant interface of orthopedic implants: importance and consequence
    Jell, G
    Kerjaschki, D
    Revell, P
    Al-Saffar, N
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 77A (01) : 119 - 127
  • [5] The bone-implant interface of dental implants in humans on the atomic scale
    Sundell, Gustav
    Dahlin, Christer
    Andersson, Martin
    Thuvander, Mattias
    ACTA BIOMATERIALIA, 2017, 48 : 445 - 450
  • [6] Doxycycline inhibits bone resorption by human interface membrane cells from aseptically loose hip replacements
    Ong, SM
    Taylor, GJS
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (03): : 456 - 461
  • [7] Osseointegration of zirconia implants: An SEM observation of the bone-implant interface
    Depprich R.
    Zipprich H.
    Ommerborn M.
    Mahn E.
    Lammers L.
    Handschel J.
    Naujoks C.
    Wiesmann H.-P.
    Kübler N.R.
    Meyer U.
    Head & Face Medicine, 4 (1)
  • [8] Mechanical properties of bone-implant interface: Analysis of hydroxyapatite coatings of varying crystallinity
    Chang, YL
    Krizan, KE
    Stanford, CM
    Keller, JC
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1518 - 1518
  • [9] Elastography of the bone-implant interface
    Heriveaux, Yoann
    Vu-Hieu Nguyen
    Geiger, Didier
    Haiat, Guillaume
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Elastography of the bone-implant interface
    Yoann Hériveaux
    Vu-Hieu Nguyen
    Didier Geiger
    Guillaume Haïat
    Scientific Reports, 9