Endovascular Catheter for Magnetic Navigation under MR Imaging Guidance: Evaluation of Safety In Vivo at 1.5T

被引:35
|
作者
Hetts, S. W. [1 ]
Saeed, M. [1 ]
Martin, A. J. [1 ]
Evans, L. [4 ]
Bernhardt, A. F. [4 ]
Malba, V. [4 ]
Settecase, F. [1 ]
Do, L. [1 ]
Yee, E. J. [1 ]
Losey, A. [3 ]
Sincic, R. [1 ]
Lillaney, P. [1 ]
Roy, S. [2 ]
Arenson, R. L. [1 ]
Wilson, M. W. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Bioengn, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Sch Med, San Francisco, CA USA
[4] Lawrence Livermore Natl Lab, Livermore, CA USA
基金
美国国家卫生研究院;
关键词
REMOTE-CONTROL; INTERVENTIONAL MRI; DEFLECTION;
D O I
10.3174/ajnr.A3530
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Endovascular navigation under MR imaging guidance can be facilitated by a catheter with steerable microcoils on the tip. Not only do microcoils create visible artifacts allowing catheter tracking, but also they create a small magnetic moment permitting remote-controlled catheter tip deflection. A side product of catheter tip electrical currents, however, is the heat that might damage blood vessels. We sought to determine the upper boundary of electrical currents safely usable at 1.5T in a coil-tipped microcatheter system. MATERIALS AND METHODS: Alumina tubes with solenoid copper coils were attached to neurovascular microcatheters with heat shrink-wrap. Catheters were tested in carotid arteries of 8 pigs. The catheters were advanced under x-ray fluoroscopy and MR imaging. Currents from 0 mA to 700 mA were applied to test heating and potential vascular damage. Postmortem histologic analysis was the primary endpoint. RESULTS: Several heat-mitigation strategies demonstrated negligible vascular damage compared with control arteries. Coil currents 300 mA resulted in no damage (0/58 samples) compared with 9 (25%) of 36 samples for > 300-mA activations (P = .0001). Tip coil activation 1 minute and a proximal carotid guide catheter saline drip > 2 mL/minute also had a nonsignificantly lower likelihood of vascular damage. For catheter tip coil activations 300 mA for 1 minute in normal carotid flow, 0 of 43 samples had tissue damage. CONCLUSIONS: Activations of copper coils at the tip of microcatheters at low currents in 1.5T MR scanners can be achieved without significant damage to blood vessel walls in a controlled experimental setting. Further optimization of catheter design and procedure protocols is necessary for safe remote control magnetic catheter guidance.
引用
收藏
页码:2083 / 2091
页数:9
相关论文
共 50 条
  • [31] A Metasurface for Multi-Nuclear Magnetic Resonance Imaging Applications at 1.5T
    Yang, Tingzhao
    Ford, Kenneth Lee
    Rao, Madhwesha
    Wild, James
    2019 13TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2019,
  • [32] Evaluation of a Portable Doppler Ultrasound Gating Device for Fetal Cardiac MR Imaging: Initial Results at 1.5T and 3T
    Kording, Fabian
    Schoennagel, Bjoern P.
    de Sousa, Manuela Tavares
    Fehrs, Kai
    Adam, Gerhard
    Yamamura, Jin
    Ruprecht, Christian
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (04) : 308 - 317
  • [33] Cardiac MR imaging and MR angiography in pediatric congenital heart disease: a comparison between 1.5T and 3.0T
    KL Nguyen
    SN Khan
    J Moriarty
    K Mohajer
    P Renella
    G Satou
    I Ayad
    S Patel
    I Boechat
    P Finn
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [34] MR diffusion imaging in acute stroke: Comparison of findings at 0.2T and 1.5T MR systems in 30 patients
    Abdala, N
    Padilha, JL
    Carrete, H
    Nogueira, RG
    Szejnfeld, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 124 - 124
  • [35] Aneurysm clips: Evaluation of MR imaging artifacts at 1.5 T
    Shellock, FG
    Kanal, E
    RADIOLOGY, 1998, 209 (02) : 563 - 566
  • [36] Superficial esophageal carcinoma: An in vitro study of high-resolution MR imaging at 1.5T
    Yamada, I
    Izumi, Y
    Kawano, T
    Yoshino, N
    Tetsumura, A
    Ohashi, K
    Shibuya, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (02) : 225 - 231
  • [37] Neurovascular contact in trigeminal neuralgia. A comparison between 3T and 1.5T MR imaging
    Echeveste, B. E.
    Minguez, A.
    Imaz, L.
    Trzeciak, M.
    Barriobero, N.
    Arregui, A.
    Trevino, C.
    Garcia de Eulate, R.
    Dominguez, P.
    Zubieta, J. L.
    Martinez-Vila, E.
    Irimia, P.
    CEPHALALGIA, 2015, 35 : 254 - 254
  • [38] A Magnetic Resonance Imaging Surface Coil Transceiver Employing a Metasurface for 1.5T Applications
    Issa, Ismail
    Ford, Kenneth Lee
    Rao, Madhwesha
    Wild, Jim M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (04) : 1085 - 1093
  • [39] Dynamic magnetic resonance imaging of carbogen challenge on awake rabbit brain at 1.5T
    Chen, Po-Chou
    Shoa, Kuan-Hsiung
    Jao, Jo-Chi
    Hsiao, Chia-Chi
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (06) : 997 - 1009
  • [40] FUNCTIONAL MAGNETIC-RESONANCE-IMAGING AT 1.5T DURING SENSORIMOTOR AND COGNITIVE TASK
    SABBAH, P
    SIMOND, G
    LEVRIER, O
    HABIB, M
    TRABAUD, V
    MURAYAMA, N
    MAZOYER, BM
    BRIANT, JF
    RAYBAUD, C
    SALAMON, G
    EUROPEAN NEUROLOGY, 1995, 35 (03) : 131 - 136