Endovascular Catheter for Magnetic Navigation under MR Imaging Guidance: Evaluation of Safety In Vivo at 1.5T

被引:35
|
作者
Hetts, S. W. [1 ]
Saeed, M. [1 ]
Martin, A. J. [1 ]
Evans, L. [4 ]
Bernhardt, A. F. [4 ]
Malba, V. [4 ]
Settecase, F. [1 ]
Do, L. [1 ]
Yee, E. J. [1 ]
Losey, A. [3 ]
Sincic, R. [1 ]
Lillaney, P. [1 ]
Roy, S. [2 ]
Arenson, R. L. [1 ]
Wilson, M. W. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Bioengn, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Sch Med, San Francisco, CA USA
[4] Lawrence Livermore Natl Lab, Livermore, CA USA
基金
美国国家卫生研究院;
关键词
REMOTE-CONTROL; INTERVENTIONAL MRI; DEFLECTION;
D O I
10.3174/ajnr.A3530
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Endovascular navigation under MR imaging guidance can be facilitated by a catheter with steerable microcoils on the tip. Not only do microcoils create visible artifacts allowing catheter tracking, but also they create a small magnetic moment permitting remote-controlled catheter tip deflection. A side product of catheter tip electrical currents, however, is the heat that might damage blood vessels. We sought to determine the upper boundary of electrical currents safely usable at 1.5T in a coil-tipped microcatheter system. MATERIALS AND METHODS: Alumina tubes with solenoid copper coils were attached to neurovascular microcatheters with heat shrink-wrap. Catheters were tested in carotid arteries of 8 pigs. The catheters were advanced under x-ray fluoroscopy and MR imaging. Currents from 0 mA to 700 mA were applied to test heating and potential vascular damage. Postmortem histologic analysis was the primary endpoint. RESULTS: Several heat-mitigation strategies demonstrated negligible vascular damage compared with control arteries. Coil currents 300 mA resulted in no damage (0/58 samples) compared with 9 (25%) of 36 samples for > 300-mA activations (P = .0001). Tip coil activation 1 minute and a proximal carotid guide catheter saline drip > 2 mL/minute also had a nonsignificantly lower likelihood of vascular damage. For catheter tip coil activations 300 mA for 1 minute in normal carotid flow, 0 of 43 samples had tissue damage. CONCLUSIONS: Activations of copper coils at the tip of microcatheters at low currents in 1.5T MR scanners can be achieved without significant damage to blood vessel walls in a controlled experimental setting. Further optimization of catheter design and procedure protocols is necessary for safe remote control magnetic catheter guidance.
引用
收藏
页码:2083 / 2091
页数:9
相关论文
共 50 条
  • [21] Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system
    Li, Ye
    Pang, Yong
    Vigneron, Daniel
    Glenn, Orit
    Xu, Duan
    Zhang, Xiaoliang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2011, 1 (01) : 24 - 30
  • [22] Phantom image quality evaluation under 3 coil settings for abdominal MR-simulation at 1.5T
    Wong, O. L.
    Yuan, J.
    Yu, S.
    Cheung, K.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S946 - S947
  • [23] Preliminary functional imaging study on an integrated 1.5T MR-Linac machine
    Kadbi, M.
    Ding, Y.
    Wang, J.
    Fuller, C. D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S915 - S916
  • [24] 1.5T susceptibility-weighted MR imaging in the diagnosis of Parkinson's disease
    Chang, M. -H.
    MOVEMENT DISORDERS, 2011, 26 : S238 - S238
  • [25] MR imaging during endovascular procedures: An evaluation of the potential for catheter heating
    Martin, Alastair J.
    Baek, Bryant
    Acevedo-Bolton, Gabriel
    Higashida, Randall T.
    Comstock, John
    Saloner, David A.
    Magnetic Resonance in Medicine, 2009, 61 (01): : 45 - 53
  • [26] In Vivo T2-mapping and Segmentation of Carotid Artery Plaque Components using Magnetic Resonance Imaging at 1.5T
    Proniewski, Bartosz
    Miszalski-Jamka, Tomasz
    Jazwiec, Przemyslaw
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 921 - 924
  • [27] MR Imaging during Endovascular Procedures: An Evaluation of the Potential for Catheter Heating
    Martin, Alastair J.
    Baek, Bryant
    Acevedo-Bolton, Gabriel
    Higashida, Randall T.
    Comstock, John
    Saloner, David A.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 45 - 53
  • [28] MR Diagnosis of Bone Metastases at 1.5T and 3T: Can STIR Imaging Be Omitted?
    Ohlmann-Knafo, S.
    Tarnoki, A. D.
    Tarnoki, D. L.
    Pickuth, D.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (10): : 924 - 932
  • [29] MR imaging of articular cartilage at 1.5T and 3.0T: Comparison of SPGR and SSFP sequences
    Kornaat, PR
    Reeder, SB
    Koo, S
    Brittain, JH
    Yu, H
    Andriacchi, TP
    Gold, GE
    OSTEOARTHRITIS AND CARTILAGE, 2005, 13 (04) : 338 - 344
  • [30] INTRACRANIAL HEMORRHAGIC LESIONS - EVALUATION WITH SPIN-ECHO AND GRADIENT-REFOCUSED MR IMAGING AT 0.5 AND 1.5T
    SEIDENWURM, D
    MENG, TK
    KOWALSKI, H
    WEINREB, JC
    KRICHEFF, II
    RADIOLOGY, 1989, 172 (01) : 189 - 194