Realistic Estimation of the Local Specific Absorption Rate of Human Head in MR Scanner at 7T

被引:0
|
作者
Fontana, Nunzia [1 ]
Monorchio, Agostino [1 ]
Stara, Riccardo [2 ]
Retico, Alessandra [2 ]
Tiberi, Gianluigi [4 ]
Tosetti, Michela [3 ]
机构
[1] Univ Pisa, Dipartimento Ingn Informaz, Via G Caruso 16, I-56122 Pisa, Italy
[2] Univ Pisa, INFN, Dipartimento Fis, I-56122 Pisa, Italy
[3] Stella Maris Sci Inst, Pisa, Italy
[4] Fondazione Imago7, Pisa, Italy
关键词
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
The evaluation of the local Specific Absorption Rate (local SAR) is a major concern in high field Magnetic Resonance (MR) systems. The investigation here presented is focused on the estimation of the Specific Absorption Rate in human head excited by a 7T surface coil. The aim of our work is to evaluate the maximum local SAR of the sample inside the scanner under realistic condition of use. The proposed methodology can be adopted to avoid the over-exposure of the body during the MR exam.
引用
收藏
页码:2024 / +
页数:2
相关论文
共 50 条
  • [41] Surface coil with reduced specific absorption rate for rat MRI at 7 T
    Sergio E. Solis-Najera
    Rodrigo Martin
    Fabian Vazquez
    Alfredo O. Rodriguez
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 599 - 608
  • [42] Specific visualization of neuromelanin-iron complex and ferric iron in the human post-mortem substantia nigra using MR relaxometry at 7T
    Lee, Hansol
    Baek, Sun-Yong
    Chun, Se Young
    Lee, Jae-Hyeok
    Cho, HyungJoon
    NEUROIMAGE, 2018, 172 : 874 - 885
  • [43] ESTIMATION OF SPECIFIC ABSORPTION RATE IN THE HUMAN LEG AND TESTICLE DUE TO A METALLIC RING
    Othman, Nazirah
    Samsuri, Noor Asmawati
    Rahim, Mohamad Kamal A.
    JURNAL TEKNOLOGI, 2015, 77 (10): : 85 - 90
  • [44] MR-EYE: High-Resolution MRI of the Human Eye and Orbit at Ultrahigh Field (7T)
    Glarin, Rebecca K.
    Nguyen, Bao N.
    Cleary, Jon O.
    Kolbe, Scott C.
    Ordidge, Roger J.
    Bui, Bang, V
    McKendrick, Allison M.
    Moffat, Bradford A.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (01) : 103 - 116
  • [45] Hybrid Monopole/Loop Coil Array for Human Head MR Imaging at 7 T
    Xinqiang Yan
    Long Wei
    Rong Xue
    Xiaoliang Zhang
    Applied Magnetic Resonance, 2015, 46 : 541 - 550
  • [46] Hybrid Monopole/Loop Coil Array for Human Head MR Imaging at 7 T
    Yan, Xinqiang
    Wei, Long
    Xue, Rong
    Zhang, Xiaoliang
    APPLIED MAGNETIC RESONANCE, 2015, 46 (05) : 541 - 550
  • [47] Cortical lesions detected with 7T MRI are associated with disruption of local cortical function and area specific symptoms
    Madsen, M. A. J.
    Wiggermann, V.
    Marques, M.
    Lundell, H.
    Cerri, S.
    Puonti, O.
    Blinkenberg, M.
    Christensen, J. Romme
    Siebner, H. R.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 416 - 417
  • [48] MRI-based anatomical model of the human head for specific absorption rate mapping
    Nikos Makris
    Leonardo Angelone
    Seann Tulloch
    Scott Sorg
    Jonathan Kaiser
    David Kennedy
    Giorgio Bonmassar
    Medical & Biological Engineering & Computing, 2008, 46 : 1239 - 1251
  • [49] Specific Absorption Rate in the Human Head due to Different Far Field Exposure Sources
    Lazarescu, Catalin
    Dafinescu, Vlad
    David, Valeriu
    PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2012), 2012, : 683 - 687
  • [50] Investigation of Hand Worn Jewellery Effects on the Specific Absorption Rate in the Human Head and Hand
    Islam, Mohammad Tariqul
    Abidin, Hafizah Zainool
    Faruque, Mohammad Rashed Iqbal
    Misran, Norbahiah
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 4559 - 4563