Realistic Estimation of the Local Specific Absorption Rate of Human Head in MR Scanner at 7T

被引:0
|
作者
Fontana, Nunzia [1 ]
Monorchio, Agostino [1 ]
Stara, Riccardo [2 ]
Retico, Alessandra [2 ]
Tiberi, Gianluigi [4 ]
Tosetti, Michela [3 ]
机构
[1] Univ Pisa, Dipartimento Ingn Informaz, Via G Caruso 16, I-56122 Pisa, Italy
[2] Univ Pisa, INFN, Dipartimento Fis, I-56122 Pisa, Italy
[3] Stella Maris Sci Inst, Pisa, Italy
[4] Fondazione Imago7, Pisa, Italy
关键词
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
The evaluation of the local Specific Absorption Rate (local SAR) is a major concern in high field Magnetic Resonance (MR) systems. The investigation here presented is focused on the estimation of the Specific Absorption Rate in human head excited by a 7T surface coil. The aim of our work is to evaluate the maximum local SAR of the sample inside the scanner under realistic condition of use. The proposed methodology can be adopted to avoid the over-exposure of the body during the MR exam.
引用
收藏
页码:2024 / +
页数:2
相关论文
共 50 条
  • [31] Study of Specific Absorption Rate (SAR) in the human head by metamaterial attachment
    Islam, M. T.
    Faruque, M. R. I.
    Misran, N.
    IEICE ELECTRONICS EXPRESS, 2010, 7 (04): : 240 - 246
  • [32] Assessment of specific absorption rate reduction in human head using metamaterial
    Faruque, Mohammad Rashed Iqbal
    Islam, Mohammad Tariqul
    Mohamed, Nik Abdullah Nik
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2014, 21 (01) : 79 - 85
  • [33] Reduction of Specific Absorption Rate (SAR) in the Human Head with Materials and Metamaterial
    Islam, Mohammad Tariqul
    Misran, Norbahiah
    Ling, Tan Sue
    Faruque, Mohammad Rashed Iqbal
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS, VOLS 1 AND 2, 2009, : 678 - 681
  • [34] Visualization and characterization of pure and coupled modes in water-based dielectric resonators on a human 7T scanner
    Webb, A. G.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 216 : 107 - 113
  • [35] Evaluation of the MRI compatibility of PET detectors modules for organ-specific inserts in a 3T and 7T MRI scanner
    Schmidt, Fabian P.
    Allen, Magdelena S.
    Ladebeck, Ralf
    Breuer, Johannes
    Judenhofer, Martin
    Schmand, Matthias
    Catana, Ciprian
    Pichler, Bernd J.
    MEDICAL PHYSICS, 2024, 51 (02) : 991 - 1006
  • [36] Dosimetric Evaluation of Specific Absorption Rate in Realistic Head Models with Different Sizes in Mobile Phone Usage
    Lu, Mai
    Ueno, Shoogo
    2014 XXXITH URSI GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM (URSI GASS), 2014,
  • [37] Calorimetric Calibration of Specific Absorption Rate (SAR) On a Compact 3T MRI Scanner
    Shu, Y.
    Tao, S.
    Yeo, D.
    Foo, T.
    Weavers, P.
    Trzasko, J.
    Huston, J.
    Bernstein, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3048 - 3048
  • [38] Prospective motion and B0 shim correction for MR spectroscopy in human brain at 7T
    Deelchand, Dinesh K.
    Joers, James M.
    Auerbach, Edward J.
    Henry, Pierre-Gilles
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (06) : 1984 - 1992
  • [39] A 7T double-tuned (1H/31P) microstrip surface RF coil for the Imago7 MR Scanner
    Retico, Alessandra
    Vitacolonna, Assunta
    Galante, Angelo
    Florio, Tiziana M.
    Cimini, Annamaria
    Stara, Riccardo
    Tiberi, Gianluigi
    Tosetti, Michela
    Fontana, Nunzia
    Manara, Giuliano
    Monorchio, Agostino
    Alecci, Marcello
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 84 - 88
  • [40] Surface coil with reduced specific absorption rate for rat MRI at 7 T
    Solis-Najera, Sergio E.
    Martin, Rodrigo
    Vazquez, Fabian
    Rodriguez, Alfredo O.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (06) : 599 - 608