Effect of Spectral Domain Optical Coherence Tomography Image Quality on Macular Thickness Measurements and Error Rate

被引:5
|
作者
Falavarjani, Khalil Ghasemi [1 ]
Mehrpuya, Amirabbas [2 ]
Amirkourjani, Foad [2 ]
机构
[1] Iran Univ Med Sci, Rassoul Akram Hosp, Dept Ophthalmol, Eye Res Ctr, Tehran, Iran
[2] Iran Univ Med Sci, Rassoul Akram Hosp, Eye Res Ctr, Tehran, Iran
关键词
Artifact; Image quality; Optical coherence tomography; RETINAL THICKNESS; SEGMENTATION ERROR; CATARACT-SURGERY; SIGNAL STRENGTH; INSTRUMENTS; DENSITY; DEVICES; MEDIA;
D O I
10.1080/02713683.2016.1179332
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effect of Topcon spectral domain optical coherence tomography (OCT) image quality on macular thickness measurements and the error rate in healthy subjects and patients with clinically significant diabetic macular edema (CSME).Methods: In this prospective, comparative case series, macular thickness measurements, and the rate of decentration and segmentation errors were evaluated before and after reducing the image quality factor (QF). The measurements were evaluated again after correcting the decentration and segmentation errors. To reduce the image QF below 45, tetracycline eye ointment was applied on the corneal surface.Results: Forty eyes of 40 subjects including 18 healthy eyes and 22 eyes with CSME were included. In both groups, the difference in central subfield thickness measurements before and after reducing the image QF was not statistically significant both before and after error correction (all P>0.05). The rate of decentration error was statistically similar before and after reducing image QF in normal and CSME eyes (P=0.50, P=0.69, respectively). However, the rate of segmentation error was statistically significantly higher after reducing image QF both in normal and CSME eyes (P=0.008 and P=0.004, respectively). In both groups, eyes with a segmentation error had higher image QF reduction (both P=0.01).Conclusion: Reducing image quality results in a higher rate of the segmentation error in normal eyes and in eyes with CSME.
引用
收藏
页码:282 / 286
页数:5
相关论文
共 50 条
  • [21] Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes
    Lin Liu
    Jun Zou
    Lili Jia
    Jian-guo Yang
    Shao-rong Chen
    Diagnostic Pathology, 9
  • [22] Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes
    Liu, Lin
    Zou, Jun
    Jia, Lili
    Yang, Jian-guo
    Chen, Shao-rong
    DIAGNOSTIC PATHOLOGY, 2014, 9
  • [23] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
  • [24] Quality and Reproducibility of Retinal Thickness Measurements in Two Spectral-Domain Optical Coherence Tomography Machines
    Krebs, Ilse
    Smretschnig, Eva
    Moussa, Sarah
    Brannath, Werner
    Womastek, Irene
    Binder, Susanne
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (09) : 6925 - 6933
  • [25] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [26] The Effect of Utilizing Image Registration Software on Central Macular Thickness Reproducibility Using Commercially Available Spectral Domain Optical Coherence Tomography
    Sedeek, R. W.
    Redenbo, E.
    Chandra, K.
    Park, S. S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [27] Reproducibility of Macular Thickness Measurements Using Cirrus Spectral Domain Optical Coherence Tomography in Neovascular Age-Related Macular Degeneration
    Scarinci, F.
    Parravano, M.
    Oddone, F.
    Boccassini, B.
    Menchini, F.
    Varano, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [28] Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema
    Ibrahim, M. A.
    Sepah, Y. J.
    Symons, R. C. A.
    Channa, R.
    Hatef, E.
    Khwaja, A.
    Bittencourt, M.
    Heo, J.
    Do, D. V.
    Nguyen, Q. D.
    EYE, 2012, 26 (03) : 454 - 462
  • [29] Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema
    M A Ibrahim
    Y J Sepah
    R C A Symons
    R Channa
    E Hatef
    A Khwaja
    M Bittencourt
    J Heo
    D V Do
    Q D Nguyen
    Eye, 2012, 26 : 454 - 462
  • [30] Comparison of Macular Thickness Measurement and Segmentation Error Rate Between Stratus and Fourier-Domain Optical Coherence Tomography
    Modjtahedi, Sara
    Chiou, Christine
    Modjtahedi, Bobeck
    Telander, David G.
    Morse, Lawrence S.
    Park, Susanna S.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (03) : 301 - 310