Validation of Monte carlo Geant4 multithreading code for a 6 MV photon beam of varian linac on the grid computing

被引:10
|
作者
Assalmi, Mustapha [1 ]
Diaf, El Yamani [1 ]
Mansour, Najim [2 ]
机构
[1] Univ Mohammed First Oujda, Multidisciplinary Fac Nador, Phys Team, Lab OLMAN RL, Oujda, Morocco
[2] Fac Sci & Tech, Errachidia, Morocco
关键词
Monte carlo; Grid computing; Dose; Medical accelerator; Photon beams; Geant4; G4Linac-MT; Multithreaded; SIMULATION;
D O I
10.1016/j.rpor.2020.09.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: To evaluate the computation time efficiency of the multithreaded code (G4Linac-MT) in the dosimetry application, using the high performance of the HPC-Marwan grid to determine with high accuracy the initial parameters of the 6 MV photon beam of Varian CLINAC 2100C. Background: The difficulty of Monte Carlo methods is the long computation time, this is one of the disadvantages of the Monte Carlo methods. Materials and methods: Calculations are performed by the multithreaded code G4Linac-MT and Geant4.10.04.p02 using the HPC-Marwan computing grid to evaluate the computing speed for each code. The multithreaded version is tested in several CPUs to evaluate the computing speed according to the number of CPUs used. The results were compared to the measurements using different types of comparisons, TPR20.10, penumbra, mean dose error and gamma index. Results: The results obtained for this work indicate a much higher computing time saving for the G4Linac-MT version compared to the Geant4.10.04 version, the computing time decreases with the number of CPUs used, can reach about 12 times if 64CPUs are used. After optimization of the initial electron beam parameters, the results of the dose simulations obtained for this work are in very good agreement with the experimental measurements with a mean dose error of up to 0.41% on the PDDs and 1.79% on the lateral dose. Conclusions: The gain in computation time leads us to perform Monte Carlo simulations with a large number of events which gives a high accuracy of the dosimetry results obtained in this work. (C) 2020 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1001 / 1010
页数:10
相关论文
共 50 条
  • [1] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    [J]. ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [2] Validation of Monte Carlo Geant4 code for a 6 MV Varian linac
    EL Bakkali, Jaafar
    EL Bardouni, Tarek
    [J]. JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (01) : 106 - 113
  • [3] Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Boukhal, H.
    Saeed, M.
    Ahmed, Abdul-Aziz
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 69 - 75
  • [4] Therapeutic dose simulation of a 6 MV Varian Linac photon beam using GEANT4
    Salama, E.
    Ali, A. S.
    Khaled, N. E.
    Radi, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [5] Monte Carlo Simulation of a 18 MV Medical Linac Photon Beam Using GATE/GEANT4
    M. Fiak
    A. Fathi
    J. Inchaouh
    A. Khouaja
    A. Benider
    M. Krim
    N. Harakat
    Z. Housni
    M. L. Bouhssa
    M. Mouadil
    Y. Elabssaoui
    O. Jdair
    [J]. Moscow University Physics Bulletin, 2021, 76 : 15 - 21
  • [6] Monte Carlo Simulation of a 18 MV Medical Linac Photon Beam Using GATE/GEANT4
    Fiak, M.
    Fathi, A.
    Inchaouh, J.
    Khouaja, A.
    Benider, A.
    Krim, M.
    Harakat, N.
    Housni, Z.
    Bouhssa, M. L.
    Mouadil, M.
    Elabssaoui, Y.
    Jdair, O.
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (01) : 15 - 21
  • [7] Determination of Dose Distributions by Monte-Carlo Simulation of 6 MV Photon Beam of Varian VitalBeam Accelerator Using Geant4 Multithreaded Code
    Chiuyo, Julius
    Lugendo, Innocent
    Muhogora, Wilbroad
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (02) : 181 - 188
  • [8] Validation of GAMOS code based on Geant4 Monte Carlo for a 12 MV Saturne43 Linac
    Al Zain, Jamal
    El Bardouni, T.
    Mohammed, Maged
    El Hajjaji, O.
    [J]. JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2019, 31 (04) : 500 - 505
  • [9] Radiation transport calculations for 50 MV photon therapy beam using the Monte Carlo code Geant4
    Larsson, S
    Svensson, R
    Gudowska, I
    Ivanchenko, V
    Brahme, A
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 503 - 507
  • [10] Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4
    Okamoto H.
    Fujita Y.
    Sakama K.
    Saitoh H.
    Kanai T.
    Itami J.
    Kohno T.
    [J]. Radiological Physics and Technology, 2014, 7 (2) : 246 - 253