Comparison of two real-time quantitative polymerase chain reaction strategies for minimal residual disease evaluation in lymphoproliferative disorders: correlation between immunoglobulin gene mutation load and real-time quantitative polymerase chain reaction performance

被引:8
|
作者
Della Starza, Irene [1 ]
Cavalli, Marzia [1 ]
Del Giudice, Ilaria [1 ]
Barbero, Daniela [2 ]
Mantoan, Barbara [2 ]
Genuardi, Elisa [2 ]
Urbano, Marina [2 ]
Mannu, Claudia [3 ]
Gazzola, Anna [1 ,3 ]
Ciabatti, Elena [1 ,4 ]
Guarini, Anna
Foa, Robin
Galimberti, Sara [4 ]
Piccaluga, Pierpaolo [3 ]
Gaidano, Gianluca [5 ]
Ladetto, Marco [2 ]
Monitillo, Luigia [2 ]
机构
[1] Univ Roma La Sapienza, Dept Cellular Biotechnol & Hematol, I-00185 Rome, Italy
[2] Univ Turin, Dept Mol Biotechnol & Hlth Sci, I-10126 Turin, Italy
[3] Univ Bologna, Dept Expt Diagnost & Specialty Med, Bologna, Italy
[4] Univ Pisa, UO Hematol, Dept Clin & Expt Med, Pisa, Italy
[5] Univ Piemonte Orientale, Div Hematol Dept Traslat Med, Novara, Italy
关键词
MRD; RQ-PCR; lymphoproliferative disorders; immunoglobulin genes; mutations; REARRANGEMENTS; LEUKEMIA; LYMPHOMA; PCR;
D O I
10.1002/hon.2095
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We compared two strategies for minimal residual disease evaluation of B-cell lymphoproliferative disorders characterized by a variable immunoglobulin heavy chain (IGH) genes mutation load. Twenty-five samples from chronic lymphocytic leukaemia (n=18) or mantle cell lymphoma (n=7) patients were analyzed. Based on IGH variable region genes, 22/25 samples carried >2% mutations, 20/25>5%. In the IGH joining region genes, 23/25 samples carried >2% mutations, 18/25>5%. Real-time quantitative polymerase chain reaction was performed on IGH genes using two strategies: method A utilizes two patient-specific primers, whereas method B employs one patient-specific and one germline primer, with different positions on the variable, diversity and joining regions. Twenty-three samples (92%) resulted evaluable using method A, only six (24%) by method B. Method B poor performance was specifically evident among mutated IGH variable/joining region cases, although no specific mutation load above, which the real-time quantitative polymerase chain reaction failed was found. The molecular strategies for minimal residual disease evaluation should be adapted to the B-cell receptor features of the disease investigated. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
下载
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [21] Electrochemical real-time polymerase chain reaction
    Yeung, Stephen S. W.
    Lee, Thomas M. H.
    Hsing, I.-Ming
    Journal of the American Chemical Society, 2006, 128 (41): : 13374 - 13375
  • [22] Comparison of reference genes for quantitative real-time polymerase chain reaction analysis of gene expression in sugarcane
    Hayati M. Iskandar
    Robert S. Simpson
    Rosanne E. Casu
    Graham D. Bonnett
    Donald J. Maclean
    John M. Manners
    Plant Molecular Biology Reporter, 2004, 22 : 325 - 337
  • [23] Comparisons of normalization methods for relative quantitative in real-time polymerase chain reaction
    Hwang, Yi-Ting
    Su, Yu-Hui
    Terng, Harn-Jing
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2017, 46 (02) : 1336 - 1359
  • [24] Identification of four squid species by quantitative real-time polymerase chain reaction
    Ye, Jian
    Feng, Junli
    Liu, Shasha
    Zhang, Yanping
    Jiang, Xiaona
    Dai, Zhiyuan
    MOLECULAR AND CELLULAR PROBES, 2016, 30 (01) : 22 - 29
  • [25] Use of quantitative real-time polymerase chain reaction to examine endometrial tissue
    Dascanio, J.
    Tschetter, J.
    Gray, A.
    Bridges, K.
    ANIMAL REPRODUCTION SCIENCE, 2006, 94 (1-4) : 254 - 258
  • [26] Rapid Quantitative Detection by Real-Time Polymerase Chain Reaction with a Polymer Chip
    Akagi, Yoshinori
    Imamura, Kazuhiko
    Kouno, Takamasa
    Nomura, Shigeru
    Kage, Shuji
    Ema, Mitsuyoshi
    Nishijima, Naoki
    Yamamoto, Kazuki
    Migita, Toshiro
    Shibasaki, Futoshi
    SENSORS AND MATERIALS, 2015, 27 (05) : 403 - 411
  • [27] Real-time quantitative diagnosis of infectious polymerase chain reaction posterior uveitis
    Dworkin, LL
    Gibler, TM
    Van Gelder, RN
    ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (11) : 1534 - 1539
  • [28] Rapid titer determination of baculovirus by quantitative real-time polymerase chain reaction
    Lo, HR
    Chao, YC
    BIOTECHNOLOGY PROGRESS, 2004, 20 (01) : 354 - 360
  • [29] Bias and Imprecision in Analysis of Real-Time Quantitative Polymerase Chain Reaction Data
    Tellinghuisen, Joel
    Spiess, Andrej-Nikolai
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8925 - 8931
  • [30] Utility of Real-Time Quantitative Polymerase Chain Reaction in Detecting Mycobacterium tuberculosis
    Lv, Zhongquan
    Zhang, Mingxin
    Zhang, Hui
    Lu, Xinxin
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017