摘要
With the increase of scanner resolution head motion in PET brain studies becomes an increasingly serious limitation. Methods to correct for motion have been proposed. In this work the realisation of a motion tracking system in a PET environment and the motion correction of list mode data with the MAF method is presented. In a phantom study the method is validated and the loss in image quality is-documented in a phantom with simulated movements. The relevance of motion correction for patient data above the level of system resolution is studied. In a real patient study we show the effect of motion and the applicability of the presented system.
引用
收藏
页码:3105 / 3107
页数:3
相关论文
共 50 条
  • [21] Motion Correction Options in PET/MRI
    Catana, Ciprian
    SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (03) : 212 - 223
  • [22] Scatter estimation and motion correction in PET
    Thielemans, Kris
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1745 - 1747
  • [23] Motion correction in PET brain studies
    Herzog, H
    Tellman, L
    Fulton, R
    Pietrzyk, U
    FOURTH INTERNATIONAL WORKSHOP ON MULTIDIMENSIONAL SYSTEMS - NDS 2005, 2005, : 178 - 181
  • [24] Effects of head movements measured during PET scans
    Atkins, MS
    Fraser, S
    Menke, M
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1776 - 1780
  • [25] Joint PET-MR respiratory motion models for clinical PET motion correction
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Wan, Simon
    McClelland, Jamie
    Barnes, Anna
    Arridge, Simon
    Ourselin, Sebastien
    Atkinson, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (17): : 6515 - 6530
  • [26] Practical PET Respiratory Motion Correction in Clinical PET/MR
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    O'Meara, Celia
    Wan, Simon
    Atkinson, David
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (06) : 890 - 896
  • [27] Respiratory motion correction in PET with gated PET/CT data
    Iglesias, J. E.
    Kimiaei, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S315 - S315
  • [28] A Generic Respiratory Motion Model for Motion Correction in PET/CT
    Fayad, H.
    Pan, T.
    Roux, C.
    Visvikis, D.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2455 - 2458
  • [29] Application of a generic motion model for PET respiratory motion correction
    Fayad, Hadi
    Pan, Tinsu
    Roux, Christian
    Visvikis, Dimitris
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [30] PET motion correction using PRESTO with ITK motion estimation
    Melissa Botelho
    Liliana Caldeira
    Juergen Scheins
    Nuno Matela
    Elena Rota Kops
    N Jon Shah
    EJNMMI Physics, 1 (Suppl 1)