Practical PET Respiratory Motion Correction in Clinical PET/MR

被引:64
|
作者
Manber, Richard [1 ]
Thielemans, Kris [2 ]
Hutton, Brian F. [2 ,3 ]
Barnes, Anna [2 ]
Ourselin, Sebastien [4 ]
Arridge, Simon [4 ]
O'Meara, Celia [5 ]
Wan, Simon [2 ]
Atkinson, David [1 ]
机构
[1] UCL, Ctr Med Imaging, Div Med, London, England
[2] UCL Hosp, Inst Nucl Med, London, England
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[4] Univ Coll London Hosp, Fac Engn, Ctr Med Imaging Comp, London NW1 2BU, England
[5] Sidra Med & Res Ctr, Doha, Qatar
基金
英国工程与自然科学研究理事会;
关键词
motion correction; PET/MR; lesion detection; lesion quantification; IMAGE-RECONSTRUCTION; MRI; LUNG;
D O I
10.2967/jnumed.114.151779
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion during PET acquisition may lead to blurring in resulting images and underestimation of uptake parameters. The advent of integrated PET/MR scanners allows us to exploit the integration of modalities, using high spatial resolution and high-contrast MR images to monitor and correct PET images degraded by motion. We proposed a practical, anatomy-independent MR-based correction strategy for PET data affected by respiratory motion and showed that it can improve image quality both for PET acquired simultaneously to the motion-capturing MR and for PET acquired up to 1 h earlier during a clinical scan. Methods: To estimate the respiratory motion, our method needs only an extra 1-min dynamic MR scan, acquired at the end of the clinical PET/MR protocol. A respiratory signal was extracted directly from the PET list-mode data. This signal was used to gate the PET data and to construct a motion model built from the dynamic MR data. The estimated motion was then incorporated into the PET image reconstruction to obtain a single motion-corrected PET image. We evaluated our method in 2 steps. The PET-derived respiratory signal was compared with an MR measure of diaphragmatic displacement via a pencil-beam navigator. The motion-corrected images were compared with uncorrected images with visual inspection, line profiles, and standardized uptake value (SUV) in focally avid lesions. Results: We showed a strong correlation between the PET-derived and MR-derived respiratory signals for 9 patients, with a mean correlation of 0.89. We then showed 4 clinical case study examples (F-18-FDG and Ga-68-DOTATATE) using the motion-correction technique, demonstrating improvements in image sharpness and reduction of respiratory artifacts in scans containing pancreatic, liver, and lung lesions as well as cardiac scans. The mean increase in peak SUV (SUVpeak) and maximum SUV (SUVmax) in a patient with 4 pancreatic lesions was 23.1% and 34.5% in PET acquired simultaneously with motion-capturing MR, and 17.6% and 24.7% in PET acquired 50 min before as part of the clinical scan. Conclusion: We showed that a respiratory signal can be obtained from raw PET data and that the clinical PET image quality can be improved using only a short additional PET/MR acquisition. Our method does not need external respiratory hardware or modification of the normal clinical MR sequences.
引用
收藏
页码:890 / 896
页数:7
相关论文
共 50 条
  • [1] PRACTICAL PET RESPIRATORY MOTION CORRECTION IN CLINICAL SIMULTANEOUS PET/MR
    Manber, Richard
    Atkinson, David
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    O'Meara, Celia
    Wan, Simon
    Ourselin, Sebastien
    Arridge, Simon
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1580 - 1583
  • [2] Joint PET-MR respiratory motion models for clinical PET motion correction
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Wan, Simon
    McClelland, Jamie
    Barnes, Anna
    Arridge, Simon
    Ourselin, Sebastien
    Atkinson, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (17): : 6515 - 6530
  • [3] MR Image-based PET Respiratory Motion Correction in PET/MR
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Wan, Ming Young Simon
    O'Meara, Celia
    Atkinson, David
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [4] Clinical Impact of Respiratory Motion Correction in Simultaneous PET/MR, Using a Joint PET/MR Predictive Motion Model
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Wan, Simon
    Fraioli, Francesco
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Atkinson, David
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (09) : 1467 - 1473
  • [5] Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI
    Richard Manber
    Kris Thielemans
    Brian Hutton
    Anna Barnes
    Sebastien Ourselin
    Simon Arridge
    Celia O'Meara
    David Atkinson
    EJNMMI Physics, 1 (Suppl 1)
  • [6] Respiratory motion correction of PET using MR-constrained PET-PET registration
    Balfour, Daniel R.
    Marsden, Paul K.
    Polycarpou, Irene
    Kolbitsch, Christoph
    King, Andrew P.
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [7] Respiratory motion correction of PET using MR-constrained PET-PET registration
    Daniel R. Balfour
    Paul K. Marsden
    Irene Polycarpou
    Christoph Kolbitsch
    Andrew P. King
    BioMedical Engineering OnLine, 14
  • [8] Comparison of MR and PET derived respiratory motion estimates for dual respiratory and cardiac motion correction in cardiac PET
    Feng, Tao
    Ahlman, Mark
    Kolbitsch, Christoph
    Guo, Liheng
    Tsui, Benjamin
    Bluemke, David
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [9] Respiratory Motion Correction of PET using Motion Parameters from MR
    Dikaios, Nikolaos
    Fryer, Tim D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2806 - 2808
  • [10] Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR
    Kolbitsch, Christoph
    Ahlman, Mark A.
    Davies-Venn, Cynthia
    Evers, Robert
    Hansen, Michael
    Peressutti, Devis
    Marsden, Paul
    Kellman, Peter
    Bluemke, David A.
    Schaeffter, Tobias
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (05) : 846 - 852