FATIGUE RESISTANCE OF CAD/CAM COMPLETE CROWNS WITH A SIMPLIFIED CEMENTATION PROCESS

被引:68
|
作者
Carvalho, Adriana O. [1 ]
Bruzi, Greciana [2 ]
Giannini, Marcelo [1 ]
Magne, Pascal [3 ]
机构
[1] Univ Estadual Campinas, Piracicaba Sch Dent, Dept Restorat Dent, Piracicaba, SP, Brazil
[2] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
[3] Univ So Calif, Ostrow Sch Dent, Los Angeles, CA USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2014年 / 111卷 / 04期
关键词
ENDODONTICALLY TREATED MOLARS; FINITE-ELEMENT-ANALYSIS; COMPOSITE RESIN; RESTORATIVE MATERIALS; OCCLUSAL VENEERS; DENTAL MATERIALS; ADHESIVE; MICROLEAKAGE; BRITTLENESS; PORCELAIN;
D O I
10.1016/j.prosdent.2013.09.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Various computer-aided design and computer-aided manufacturing (CAD/CAM) materials are available to fabricate complete crowns. The type of material may have an effect on the longevity of these restorations. Purpose. To evaluate the fatigue resistance, load-to-failure, failure mode, and antagonistic wear of complete molar computer-aided design and computer-aided manufacturing (CAD/CAM) crowns made of resin nanoceramic (RNC), feldspathic glass ceramic (FEL), or lithium disilicate (LD) placed with a simplified cementation process. Material and methods. Forty-five molars received a standardized complete crown preparation and were restored with CAD/CAM crowns (1.5-mm thickness, n=15) made of RNC, FEL, and LD. After cementation, the restorations were submitted to cyclic isometric loading: 200 (x5000), 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30 000 cycles each. Surviving specimens were axially loaded until failure or to a maximum load of 4500 N. The specimens were analyzed as to failure mode: catastrophic, possibly repairable, and repairable. The groups were compared by using the life table survival analysis and the t test (alpha=.05). Results. All the specimens survived the fatigue process until the 800-N step. The survival rate of RNC was 80%, LD 93.3%, and FEL 6.6%. The survival of RNC and LD crowns did not differ from each other but exceeded that of FEL. Postfatigue load-tofailure test was 2500 N (FEL), 3122 N (RNC), and 3237 N (LD). No catastrophic failure occurred in the fatigue test, whereas all of the specimens in the load-to-failure test exhibited catastrophic fractures. Crowns made of RNC seemed to generate the least amount of antagonistic wear. Conclusions. Posterior crowns made of RNC and LD were not statistically different, and both had significantly higher fatigue resistance than FEL. All materials survived beyond the normal range of masticatory forces, and all failures were possibly re-restorable except those in the load-to-failure test. RNC crowns seemed to cause less wear of the antagonist.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 50 条
  • [31] Effect of resin cement space on the fatigue behavior of bonded CAD/CAM leucite ceramic crowns
    Venturini, Andressa Borin
    Wandscher, Vinicius Felipe
    Estivalete Marchionatti, Ana Maria
    Evangelisti, Edoardo
    Ramos, Gabriela Freitas
    Melo, Renata Marques
    May, Liliana Gressler
    Baldissara, Paolo
    Valandro, Luiz Felipe
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 110 (110)
  • [32] Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns
    Kim, Jae-Hong
    Oh, Seunghan
    Uhm, Soo-Hyuk
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [33] Resistance against bacterial leakage of four luting agents used for cementation of complete cast crowns
    Zmener, Osvaldo
    Pameijer, Cornelis H.
    Hernandez, Sandra
    AMERICAN JOURNAL OF DENTISTRY, 2014, 27 (01): : 51 - 55
  • [34] Marginal accuracy of CAD/CAM crowns compared to conventional ceramic crowns.
    Runge, J
    Kunzelmann, KH
    Hickel, R
    Perry, R
    Kugel, G
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1244 - 1244
  • [35] Fracture analysis of monolithic CAD-CAM crowns
    Kashkari, Afnan
    Yilmaz, Burak
    Brantley, William A.
    Schricker, Scott R.
    Johnston, William M.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (04) : 346 - 352
  • [36] CAD/CAM Technology for Implant Abutments, Crowns, and Superstructures
    Kapos, Theodoros
    Evans, Christopher
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 : 117 - 136
  • [37] Correlation between accuracy of crowns fabricated using CAD/CAM and elastic deformation of CAD/CAM materials
    Yara, A
    Goto, S
    Ogura, H
    DENTAL MATERIALS JOURNAL, 2004, 23 (04) : 572 - 576
  • [38] In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns
    Martin Rosentritt
    Sebastian Hahnel
    Frank Engelhardt
    Michael Behr
    Verena Preis
    Clinical Oral Investigations, 2017, 21 : 1213 - 1219
  • [39] Fracture Resistance of Two Different Composite Resin CAD/CAM Crowns Bonded to Titanium Abutments
    Fernandez-Villar, Sandra
    Cano-Batalla, Jordi
    Cabratosa-Termes, Josep
    Canto-Naves, Oriol
    Arregui, Maria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (06) : 648 - 655
  • [40] Comparison of Fracture Resistance for Chairside CAD/CAM Lithium Disilicate Crowns and Overlays with Different Designs
    Jurado, Carlos Alberto
    Kaleinikova, Zinaida
    Tsujimoto, Akimasa
    Trevino, Daniel Alberto Cortes
    Seghi, Robert R.
    Lee, Damian J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (04): : 341 - 347