FATIGUE RESISTANCE OF CAD/CAM COMPLETE CROWNS WITH A SIMPLIFIED CEMENTATION PROCESS

被引:68
|
作者
Carvalho, Adriana O. [1 ]
Bruzi, Greciana [2 ]
Giannini, Marcelo [1 ]
Magne, Pascal [3 ]
机构
[1] Univ Estadual Campinas, Piracicaba Sch Dent, Dept Restorat Dent, Piracicaba, SP, Brazil
[2] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
[3] Univ So Calif, Ostrow Sch Dent, Los Angeles, CA USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2014年 / 111卷 / 04期
关键词
ENDODONTICALLY TREATED MOLARS; FINITE-ELEMENT-ANALYSIS; COMPOSITE RESIN; RESTORATIVE MATERIALS; OCCLUSAL VENEERS; DENTAL MATERIALS; ADHESIVE; MICROLEAKAGE; BRITTLENESS; PORCELAIN;
D O I
10.1016/j.prosdent.2013.09.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Various computer-aided design and computer-aided manufacturing (CAD/CAM) materials are available to fabricate complete crowns. The type of material may have an effect on the longevity of these restorations. Purpose. To evaluate the fatigue resistance, load-to-failure, failure mode, and antagonistic wear of complete molar computer-aided design and computer-aided manufacturing (CAD/CAM) crowns made of resin nanoceramic (RNC), feldspathic glass ceramic (FEL), or lithium disilicate (LD) placed with a simplified cementation process. Material and methods. Forty-five molars received a standardized complete crown preparation and were restored with CAD/CAM crowns (1.5-mm thickness, n=15) made of RNC, FEL, and LD. After cementation, the restorations were submitted to cyclic isometric loading: 200 (x5000), 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30 000 cycles each. Surviving specimens were axially loaded until failure or to a maximum load of 4500 N. The specimens were analyzed as to failure mode: catastrophic, possibly repairable, and repairable. The groups were compared by using the life table survival analysis and the t test (alpha=.05). Results. All the specimens survived the fatigue process until the 800-N step. The survival rate of RNC was 80%, LD 93.3%, and FEL 6.6%. The survival of RNC and LD crowns did not differ from each other but exceeded that of FEL. Postfatigue load-tofailure test was 2500 N (FEL), 3122 N (RNC), and 3237 N (LD). No catastrophic failure occurred in the fatigue test, whereas all of the specimens in the load-to-failure test exhibited catastrophic fractures. Crowns made of RNC seemed to generate the least amount of antagonistic wear. Conclusions. Posterior crowns made of RNC and LD were not statistically different, and both had significantly higher fatigue resistance than FEL. All materials survived beyond the normal range of masticatory forces, and all failures were possibly re-restorable except those in the load-to-failure test. RNC crowns seemed to cause less wear of the antagonist.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 50 条
  • [21] Effect of Thermomechanical Loading on the Cementation Interface of Implant-Supported CAD/CAM Crowns Luted to Titanium Abutments
    Ioannidis, Alexis
    Gil, Alfonso
    Hammerle, Christoph H. F.
    Jung, Ronald E.
    Zinelis, Spiros
    Eliades, George
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (06) : 656 - 662
  • [22] Influence of the resin cement thickness on the fatigue failure loads of CAD/CAM feldspathic crowns
    May, Liliana Gressler
    Kelly, J. Robert
    Bottino, Marco Antonio
    Hill, Tom
    DENTAL MATERIALS, 2015, 31 (08) : 895 - 900
  • [23] Fatigue performance of adhesively luted glass or polycrystalline CAD-CAM monolithic crowns
    Alves, Daniela Meira
    Cadore-Rodrigues, Ana Carolina
    Prochnow, Catina
    de Lima Burgo, Thiago Augusto
    Spazzin, Aloisio Oro
    Bacchi, Atais
    Valandro, Luiz Felipe
    Rocha Pereira, Gabriel Kalil
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (01): : 119 - 127
  • [24] Fatigue Resistance of 2 Different CAD/CAM Glass-Ceramic Materials Used for Single-Tooth Implant Crowns
    Cavusoglu, Yeliz
    Sahin, Erdal
    Gurbuz, Riza
    Akca, Kivanc
    IMPLANT DENTISTRY, 2011, 20 (05) : 374 - 378
  • [25] Fracture resistance of CAD/CAM blocks cemented on dentin using different cementation strategies
    Anuntasainont, Munlika
    Po-ngam, Nanthiphorn
    Luhrs, Anne-Katrin
    Neoh, Siew Peng
    Pongprueksa, Pong
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (04) : 603 - 609
  • [26] Effect of cementation and aging on the marginal fit of veneered and monolithic zirconia and metal-ceramic CAD-CAM crowns
    Del Pinal, Maria
    Lopez-Suarez, Carlos
    Bartolome, Jose F.
    Volpato, Claudia AM.
    Suarez, Maria J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 323.e1 - 323.e7
  • [27] TEMPORARY CEMENTATION OF ACRYLIC RESIN AND CAST COMPLETE CROWNS
    ISHIKIRIAMA, A
    BUSATO, ALS
    NAVARRO, MFD
    MONDELLI, J
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (05): : 637 - 641
  • [28] Fatigue behavior of resin-modified monolithic CAD-CAM RNC crowns and endocrowns
    Rocca, G. T.
    Sedlakova, P.
    Saratti, C. M.
    Sedlacek, R.
    Gregor, L.
    Rizcalla, N.
    Feilzer, A. J.
    Krejci, I.
    DENTAL MATERIALS, 2016, 32 (12) : E338 - E350
  • [29] FRACTURE-BEHAVIOR OF CAD/CAM CERAMIC CROWNS BEFORE AND AFTER CYCLIC FATIGUE AGING
    Garoushi, Sufyan
    Sailynoja, Eija
    Vallittu, Pekka K.
    Lassila, Lippo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (05) : E29 - E37
  • [30] Fatigue Behavior of Different CAD/CAM Materials for Monolithic, Implant-Supported Molar Crowns
    Sotto-Maior, Bruno Salles
    Carneiro, Rafael Correa
    Francischone, Carlos Eduardo
    Souza Picorelli Assis, Neuza Maria
    Devito, Karina Lopes
    Senna, Plinio Mendes
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E548 - E551