FATIGUE RESISTANCE OF CAD/CAM COMPLETE CROWNS WITH A SIMPLIFIED CEMENTATION PROCESS

被引:68
|
作者
Carvalho, Adriana O. [1 ]
Bruzi, Greciana [2 ]
Giannini, Marcelo [1 ]
Magne, Pascal [3 ]
机构
[1] Univ Estadual Campinas, Piracicaba Sch Dent, Dept Restorat Dent, Piracicaba, SP, Brazil
[2] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
[3] Univ So Calif, Ostrow Sch Dent, Los Angeles, CA USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2014年 / 111卷 / 04期
关键词
ENDODONTICALLY TREATED MOLARS; FINITE-ELEMENT-ANALYSIS; COMPOSITE RESIN; RESTORATIVE MATERIALS; OCCLUSAL VENEERS; DENTAL MATERIALS; ADHESIVE; MICROLEAKAGE; BRITTLENESS; PORCELAIN;
D O I
10.1016/j.prosdent.2013.09.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Various computer-aided design and computer-aided manufacturing (CAD/CAM) materials are available to fabricate complete crowns. The type of material may have an effect on the longevity of these restorations. Purpose. To evaluate the fatigue resistance, load-to-failure, failure mode, and antagonistic wear of complete molar computer-aided design and computer-aided manufacturing (CAD/CAM) crowns made of resin nanoceramic (RNC), feldspathic glass ceramic (FEL), or lithium disilicate (LD) placed with a simplified cementation process. Material and methods. Forty-five molars received a standardized complete crown preparation and were restored with CAD/CAM crowns (1.5-mm thickness, n=15) made of RNC, FEL, and LD. After cementation, the restorations were submitted to cyclic isometric loading: 200 (x5000), 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30 000 cycles each. Surviving specimens were axially loaded until failure or to a maximum load of 4500 N. The specimens were analyzed as to failure mode: catastrophic, possibly repairable, and repairable. The groups were compared by using the life table survival analysis and the t test (alpha=.05). Results. All the specimens survived the fatigue process until the 800-N step. The survival rate of RNC was 80%, LD 93.3%, and FEL 6.6%. The survival of RNC and LD crowns did not differ from each other but exceeded that of FEL. Postfatigue load-tofailure test was 2500 N (FEL), 3122 N (RNC), and 3237 N (LD). No catastrophic failure occurred in the fatigue test, whereas all of the specimens in the load-to-failure test exhibited catastrophic fractures. Crowns made of RNC seemed to generate the least amount of antagonistic wear. Conclusions. Posterior crowns made of RNC and LD were not statistically different, and both had significantly higher fatigue resistance than FEL. All materials survived beyond the normal range of masticatory forces, and all failures were possibly re-restorable except those in the load-to-failure test. RNC crowns seemed to cause less wear of the antagonist.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 50 条
  • [1] Fatigue resistance of ultrathin CAD/CAM complete crowns with a simplified cementation process
    Magne, Pascal
    Carvalho, Adriana O.
    Bruzi, Greciana
    Giannini, Marcelo
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 574 - 579
  • [2] Fatigue resistance of CAD/CAM resin composite molar crowns
    Shembish, Fatma A.
    Tong, Hui
    Kaizer, Marina
    Janal, Malvin N.
    Thompson, Van P.
    Opdam, Niek J.
    Zhang, Yu
    DENTAL MATERIALS, 2016, 32 (04) : 499 - 509
  • [3] Influence of preparation, fitting, and cementation on the vitro performance and fracture resistance of CAD/CAM crowns
    Rosentritt, Martin
    Preis, Verena
    Behr, Michael
    Hahnel, Sebastian
    JOURNAL OF DENTISTRY, 2017, 65 : 70 - 75
  • [4] Fatigue resistance of monolithic CAD/CAM ceramic crowns on human premolars
    Homaei, Ehsan
    Farhangdoost, Khalil
    Pow, Edmond Ho Nang
    Matinlinna, Jukka Pekka
    Akbari, Majid
    Tsoi, James Kit-Hon
    CERAMICS INTERNATIONAL, 2016, 42 (14) : 15709 - 15717
  • [5] Fatigue Resistance and Microleakage of CAD/CAM Ceramic and Composite Molar Crowns
    Kassem, Amr S.
    Atta, Osama
    El-Mowafy, Omar
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (01): : 28 - 32
  • [6] Fatigue of CAD/CAM milled crowns.
    Tyan, B
    Pober, R
    Giordano, R
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A484 - A484
  • [7] Cementation Protocol for Bonding Zirconia Crowns to Titanium Base CAD/CAM Abutments
    Zahoui, Abbas
    Bergamo, Edmara T. P.
    Marun, Manoela M.
    Silva, Kimberly P.
    Coelho, Paulo G.
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (05) : 527 - 535
  • [8] Adhesive Cementation Promotes Higher Fatigue Resistance to Zirconia Crowns
    Campos, F.
    Valandro, L. F.
    Feitosa, S. A.
    Kleverlaan, C. J.
    Feilzer, A. J.
    de Jager, N.
    Bottino, M. A.
    OPERATIVE DENTISTRY, 2017, 42 (02) : 215 - 224
  • [9] Influence of cementation on in vitro performance, marginal adaptation and fracture resistance of CAD/CAM-fabricated ZLS molar crowns
    Preis, Verena
    Behr, Michael
    Hahnel, Sebastian
    Rosentritt, Martin
    DENTAL MATERIALS, 2015, 31 (11) : 1363 - 1369
  • [10] The flexural strength of CAD/CAM polymer crowns and the effect of artificial ageing on the fracture resistance of CAD/CAM polymer and ceramic single crowns
    Anna Winter
    Axel Schurig
    Engelke Rasche
    Franziska Rösner
    Lisa Kanus
    Marc Schmitter
    Journal of Materials Science: Materials in Medicine, 2020, 31