Three-dimensional isotropic fast spin-echo MR lymphangiography of T1-weighted and intermediate-weighted pulse sequences in patients with lymphoedema

被引:10
|
作者
Jeon, J. Y.
Lee, S. H. [1 ,2 ]
Shin, M. J.
Chung, H. W.
Lee, M. H.
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
关键词
MAGNETIC-RESONANCE LYMPHOGRAPHY; LYMPHOVENOUS MICROSURGICAL SHUNTS; LOWER-LIMBS; EXPERIENCE; CONTRAST; KNEE; ARTHROGRAPHY; ACQUISITION; GADOBUTROL; DIAGNOSIS;
D O I
10.1016/j.crad.2015.10.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the feasibility of magnetic resonance (MR) lymphangiography acquired using three-dimensional (3D) isotropic T1-weighted fast spin-echo (FSE) and 3D isotropic intermediate-weighted FSE sequences, as the new method of MR lymphangiography, and to compare the results of these two methods in patients with lymphoedema. MATERIALS AND METHODS: Thirty-three extremities of 27 patients with primary or secondary lymphoedema and who had undergone radionuclide lymphoscintigraphy and MR lymphangiography with 3D isotropic T1-weighted FSE and 3D isotropic intermediate-weighted FSE were included in the study. The results of both imaging techniques were independently reviewed by two readers in consensus who rated the lymphatic drainage pattern, the quality of the depiction of lymphatic vessels and lymph nodes, and the level of lymph vessel enhancement. The assessment scores of each imaging sequence were compared using the Wilcoxon signed-rank test. The results were expressed as means with standard deviations. RESULTS: More lymphatic vessels were visualised on T1-weighted FSE than on intermediate-weighted FSE (p<0.001). As more lymphatic vessels were detected on T1-weighted FSE, the per-extremity grade of the lymphatic drainage pattern was higher (p = 0.046) and the visible levels of lymph-vessel enhancement were also significantly higher (p = 0.004) on the T1-weighted FSE sequence, whereas the conspicuity of lymph nodes was superior on intermediate-weighted FSE (p = 0.004). CONCLUSION: MR lymphangiography using the 3D FSE pulse sequence is a feasible and noticeable new technique of MR lymphangiography. Between the two applicable protocols used, T1-weighted FSE provided better information regarding lymphatic vessels and their drainage, whereas intermediate-weighted FSE has the advantage of depicting lymph nodes in lymphoedematous extremities. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E56 / E63
页数:8
相关论文
共 50 条
  • [41] Comparison of conventional and turbo spin-echo T1-weighted MR imaging in acute knee trauma
    Eustace, S
    Hentzen, P
    Adams, J
    Harper, K
    Jara, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1393 - 1395
  • [42] Hyperintense benign liver lesions on spin-echo T1-weighted MR images: pathologic correlations
    D. Mathieu
    M. Paret
    A.-E. Mahfouz
    F. Caseiro-Alves
    J. Tran Van Nhieu
    M.-C. Anglade
    A. Rahmouni
    N. Vasile
    Abdominal Imaging, 1997, 22 : 410 - 417
  • [43] Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla
    Lavdas, Eleftherios
    Vlychou, Marianna
    Arikidis, Nikos
    Kapsalaki, Eftychia
    Roka, Violetta
    Fezoulidis, Ioannis V.
    ACTA RADIOLOGICA, 2010, 51 (03) : 290 - 295
  • [44] Fat-suppressed T2-weighted MR imaging of hepatocellular carcinoma and metastases: Comparison of conventional spin-echo, fast spin-echo, and echoplanar pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Itoh, K
    Hori, M
    Inaba, Y
    Kondo, H
    Yokoyama, R
    Nakamura, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (01): : 25 - 32
  • [45] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437
  • [46] SQUAMOUS-CELL CARCINOMA OF THE ORAL CAVITY - MR FINDINGS AND VALUE OF T1-WEIGHTED VERSUS T2-WEIGHTED FAST SPIN-ECHO IMAGES
    YASUMOTO, M
    SHIBUYA, H
    TAKEDA, M
    KORENAGA, T
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (04) : 981 - 987
  • [47] Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images
    Maeder, Yael
    Dunet, Vincent
    Richard, Raphael
    Becce, Fabio
    Omoumi, Patrick
    RADIOLOGY, 2018, 286 (03) : 853 - 864
  • [48] MR imaging of brain: Comparison between SS-FSE and fast spin-echo T2-weighted pulse sequences
    Seo, JJ
    Kang, HK
    Jeong, GW
    Jeong, YY
    Kim, JK
    Park, JG
    Chung, TW
    Kim, YH
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 : 125 - 129
  • [49] Liver T2-weighted MR imaging: Assessment of a three-dimensional fast spin-echo with extended echo train acquisition sequence at 1.5 Tesla
    Denoiseux, Celine Cotereau
    Boulay-Coletta, Isabelle
    Nakache, Jean-Pierre
    Claude, Isabelle Dufour
    Zins, Marc
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) : 336 - 343
  • [50] Spatial relationship between vestibular schwannoma and facial nerve on three-dimensional T2-weighted fast spin-echo MR images
    Sartoretti-Schefer, S
    Kollias, S
    Valavanis, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (05) : 810 - 816