Three-dimensional isotropic fast spin-echo MR lymphangiography of T1-weighted and intermediate-weighted pulse sequences in patients with lymphoedema

被引:10
|
作者
Jeon, J. Y.
Lee, S. H. [1 ,2 ]
Shin, M. J.
Chung, H. W.
Lee, M. H.
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
关键词
MAGNETIC-RESONANCE LYMPHOGRAPHY; LYMPHOVENOUS MICROSURGICAL SHUNTS; LOWER-LIMBS; EXPERIENCE; CONTRAST; KNEE; ARTHROGRAPHY; ACQUISITION; GADOBUTROL; DIAGNOSIS;
D O I
10.1016/j.crad.2015.10.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the feasibility of magnetic resonance (MR) lymphangiography acquired using three-dimensional (3D) isotropic T1-weighted fast spin-echo (FSE) and 3D isotropic intermediate-weighted FSE sequences, as the new method of MR lymphangiography, and to compare the results of these two methods in patients with lymphoedema. MATERIALS AND METHODS: Thirty-three extremities of 27 patients with primary or secondary lymphoedema and who had undergone radionuclide lymphoscintigraphy and MR lymphangiography with 3D isotropic T1-weighted FSE and 3D isotropic intermediate-weighted FSE were included in the study. The results of both imaging techniques were independently reviewed by two readers in consensus who rated the lymphatic drainage pattern, the quality of the depiction of lymphatic vessels and lymph nodes, and the level of lymph vessel enhancement. The assessment scores of each imaging sequence were compared using the Wilcoxon signed-rank test. The results were expressed as means with standard deviations. RESULTS: More lymphatic vessels were visualised on T1-weighted FSE than on intermediate-weighted FSE (p<0.001). As more lymphatic vessels were detected on T1-weighted FSE, the per-extremity grade of the lymphatic drainage pattern was higher (p = 0.046) and the visible levels of lymph-vessel enhancement were also significantly higher (p = 0.004) on the T1-weighted FSE sequence, whereas the conspicuity of lymph nodes was superior on intermediate-weighted FSE (p = 0.004). CONCLUSION: MR lymphangiography using the 3D FSE pulse sequence is a feasible and noticeable new technique of MR lymphangiography. Between the two applicable protocols used, T1-weighted FSE provided better information regarding lymphatic vessels and their drainage, whereas intermediate-weighted FSE has the advantage of depicting lymph nodes in lymphoedematous extremities. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E56 / E63
页数:8
相关论文
共 50 条
  • [31] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [32] THREE-DIMENSIONAL (3D) INTERMEDIATE-WEIGHTED FAST SPIN-ECHO MAGNETIC RESONANCE IMAGING (MRI) FOR SEMIQUANTITATIVE WHOLE ORGAN ASSESSMENT OF KNEE OSTEOARTHRITIS
    Crema, M. D.
    Nogueira-Barbosa, M. H.
    Roemer, F. W.
    Marra, M. D.
    Niu, J.
    Chagas-Neto, F. A.
    Guermazi, A.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 : S172 - S172
  • [33] Correction of intensity nonuniformity in spin-echo T1-weighted images
    Collewet, G
    Davenel, A
    Toussaint, C
    Akoka, S
    MAGNETIC RESONANCE IMAGING, 2002, 20 (04) : 365 - 373
  • [34] Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist
    Park, Hee Jin
    Lee, So Yeon
    Kang, Kyung A.
    Kim, Eun Young
    Shin, Hun Kyu
    Park, Se Jin
    Park, Jai Hyung
    Kim, Eugene
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1084):
  • [35] Vertebral artery dissection diagnosed by T1-weighted volume isotropic turbo spin-echo acquisition
    Sugiyama, Yukio
    Ogawa, Atsushi
    Esa, Yoshiki
    Watanabe, Akihiro
    Kobayashi, Junya
    Takahashi, Daisuke
    NEUROLOGY AND CLINICAL NEUROSCIENCE, 2021, 9 (01): : 148 - 149
  • [36] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T:: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schröder, RJ
    ACTA RADIOLOGICA, 2005, 46 (01) : 67 - 73
  • [37] The usefulness of the oblique coronal plane of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI in the evaluation of posterior cruciate ligament reconstruction with allograft: Comparison with the oblique coronal plane of two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Choi, Yoon Jung
    Choi, Seon Hyeong
    Kim, Mi Sung
    Ahn, Jin Hwan
    Park, Ji Yeon
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 105 - 110
  • [38] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365
  • [39] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Jing Zhang
    Lang Chen
    Qiu-Xia Wang
    Rong Liu
    Wen-Zhen Zhu
    Xin Luo
    Li Peng
    Wei Xiong
    Neuroradiology, 2015, 57 : 357 - 365
  • [40] Hyperintense benign liver lesions on spin-echo T1-weighted MR images: Pathologic correlations
    Mathieu, D
    Paret, M
    Mahfouz, AE
    CaseiroAlves, F
    Nhieu, JTV
    Anglade, MC
    Rahmouni, A
    Vasile, N
    ABDOMINAL IMAGING, 1997, 22 (04): : 410 - 417