Three-dimensional isotropic fast spin-echo MR lymphangiography of T1-weighted and intermediate-weighted pulse sequences in patients with lymphoedema

被引:10
|
作者
Jeon, J. Y.
Lee, S. H. [1 ,2 ]
Shin, M. J.
Chung, H. W.
Lee, M. H.
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
关键词
MAGNETIC-RESONANCE LYMPHOGRAPHY; LYMPHOVENOUS MICROSURGICAL SHUNTS; LOWER-LIMBS; EXPERIENCE; CONTRAST; KNEE; ARTHROGRAPHY; ACQUISITION; GADOBUTROL; DIAGNOSIS;
D O I
10.1016/j.crad.2015.10.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the feasibility of magnetic resonance (MR) lymphangiography acquired using three-dimensional (3D) isotropic T1-weighted fast spin-echo (FSE) and 3D isotropic intermediate-weighted FSE sequences, as the new method of MR lymphangiography, and to compare the results of these two methods in patients with lymphoedema. MATERIALS AND METHODS: Thirty-three extremities of 27 patients with primary or secondary lymphoedema and who had undergone radionuclide lymphoscintigraphy and MR lymphangiography with 3D isotropic T1-weighted FSE and 3D isotropic intermediate-weighted FSE were included in the study. The results of both imaging techniques were independently reviewed by two readers in consensus who rated the lymphatic drainage pattern, the quality of the depiction of lymphatic vessels and lymph nodes, and the level of lymph vessel enhancement. The assessment scores of each imaging sequence were compared using the Wilcoxon signed-rank test. The results were expressed as means with standard deviations. RESULTS: More lymphatic vessels were visualised on T1-weighted FSE than on intermediate-weighted FSE (p<0.001). As more lymphatic vessels were detected on T1-weighted FSE, the per-extremity grade of the lymphatic drainage pattern was higher (p = 0.046) and the visible levels of lymph-vessel enhancement were also significantly higher (p = 0.004) on the T1-weighted FSE sequence, whereas the conspicuity of lymph nodes was superior on intermediate-weighted FSE (p = 0.004). CONCLUSION: MR lymphangiography using the 3D FSE pulse sequence is a feasible and noticeable new technique of MR lymphangiography. Between the two applicable protocols used, T1-weighted FSE provided better information regarding lymphatic vessels and their drainage, whereas intermediate-weighted FSE has the advantage of depicting lymph nodes in lymphoedematous extremities. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E56 / E63
页数:8
相关论文
共 50 条
  • [1] Comparison of Three-dimensional Isotropic T1-weighted Fast Spin-Echo MR Arthrography with Two-dimensional MR Arthrography of the Shoulder
    Choo, Hye Jung
    Lee, Sun Joo
    Kim, Ok-Hwoa
    Seo, Seung Suk
    Kim, Jung Han
    RADIOLOGY, 2012, 262 (03) : 921 - 931
  • [2] Diagnosis of acetabular labral tears: comparison of three-dimensional intermediate-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography at 3.0 T
    Park, So Young
    Park, Ji Seon
    Jin, Wook
    Rhyu, Kee Hyung
    Ryu, Kyung Nam
    ACTA RADIOLOGICA, 2013, 54 (01) : 75 - 82
  • [3] Qualitative and Quantitative Assessment of Isotropic Ankle Magnetic Resonance Imaging: Three-Dimensional Isotropic Intermediate-Weighted Turbo Spin Echo versus Three-Dimensional. Isotropic Fast Field Echo Sequences
    Kim, Hyun Su
    Yoon, Young Cheol
    Kwon, Jong Won
    Choe, Bong-Keun
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (04) : 443 - 449
  • [4] MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Giovanni Foti
    Paolo Avanzi
    William Mantovani
    Flavia Dal Corso
    Emanuele Demozzi
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2017, 122 : 353 - 360
  • [5] MR arthrography of the hip: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Giovanni Foti
    Antonio Campacci
    Michele Conati
    Mirko Trentadue
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2017, 122 : 774 - 784
  • [6] MR arthrography of the hip: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Foti, Giovanni
    Campacci, Antonio
    Conati, Michele
    Trentadue, Mirko
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2017, 122 (10): : 774 - 784
  • [7] MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Foti, Giovanni
    Avanzi, Paolo
    Mantovani, William
    Dal Corso, Flavia
    Demozzi, Emanuele
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2017, 122 (05): : 353 - 360
  • [8] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Andrew B. Wolff
    Lorenzo L. Pesce
    Jim S. Wu
    L. Ryan Smart
    Michael J. Medvecky
    Andrew H. Haims
    Skeletal Radiology, 2009, 38 : 21 - 29
  • [9] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Wolff, Andrew B.
    Pesce, Lorenzo L.
    Wu, Jim S.
    Smart, L. Ryan
    Medvecky, Michael J.
    Haims, Andrew H.
    SKELETAL RADIOLOGY, 2009, 38 (01) : 21 - 29
  • [10] Comparison of T1-weighted Spin-Echo and 3D T1-weighted multishot echo planar pulse sequences in imaging the brain at 1T
    Karantanas, AH
    Papanikolaou, N
    Vasiou, K
    Lavdas, E
    MAGNETIC RESONANCE IMAGING, 1999, 17 (05) : 663 - 668