Modeling temperature effects on a Coriolis mass flowmeter

被引:6
|
作者
Costa, Fabio Ouverney [1 ]
Pope, Jodie G. [2 ]
Gillis, Keith A. [2 ]
机构
[1] Inst Nacl Metrol, Directory Sci & Ind Metrol, Fluid Dynam Metrol Div, Duque De Caxias, RJ, Brazil
[2] NIST, Fluid Metrol Grp, Gaithersburg, MD 20899 USA
关键词
Coriolis meter; Temperature-effects; Physical model; Flowmeter; Cryogenic; ELASTIC-CONSTANTS;
D O I
10.1016/j.flowmeasinst.2020.101811
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Coriolis mass flowmeters are used for many applications, including as transfer standards for proficiency testing and liquified natural gas (LNG) custody transfer. We developed a model to explain the temperature dependence of a Coriolis meter down to cryogenic temperatures. As a first step, we tested our model over the narrow temperature range of 285 K to 318 K in this work. The temperature dependence predicted by the model agrees with experimental data within +/- 0.08 %; the model uncertainty is 0.16 % (95 % confidence level) over the temperature range of this work. Here, basic concepts of Coriolis flowmeters will be presented, and correction coefficients will be proposed that are valid down to 5 K based on literature values of material properties.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] MODELING OF THE CORIOLIS MASS FLOWMETER
    SULTAN, G
    HEMP, J
    JOURNAL OF SOUND AND VIBRATION, 1989, 132 (03) : 473 - 489
  • [2] Modeling temperature effects on a Coriolis mass flowmeter (vol 76, 101811, 2020)
    Costa, Fabio Ouverney
    Pope, Jodie G.
    Gillis, Keith A.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 79
  • [3] Resonant Coriolis mass flowmeter
    Fan, S.C.
    Liu, G.J.
    Song, Z.S.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2000, 26 (06): : 653 - 655
  • [4] Largest Coriolis mass flowmeter
    不详
    HYDROCARBON PROCESSING, 2008, 87 (03): : 26 - +
  • [5] Smart Coriolis mass flowmeter
    Shanmugavalli, M.
    Umapathy, M.
    Uma, G.
    MEASUREMENT, 2010, 43 (04) : 549 - 555
  • [6] Modeling and sensitivity analysis of Coriolis mass flowmeter with finite element method
    College of Mechanical and Electrical Engineering, Hehai University, Changzhou 213022, China
    Huagong Zidonghua Ji Yibiao, 2006, 1 (78-81):
  • [7] Theoretical Dynamic Modeling of Coriolis Mass Flowmeter Arcuate Type for Fluctuation Flow
    Pramana, Putu Agus Aditya
    Kurniadi, Deddy
    Siregar, Parsaulian I.
    2013 3RD INTERNATIONAL CONFERENCE ON INSTRUMENTATION CONTROL AND AUTOMATION (ICA 2013), 2013, : 57 - 62
  • [8] Direct viscosity measurement with a Coriolis mass flowmeter
    Fuchs, M
    Drahm, W
    Bjönnes, H
    Sprich, HJ
    SENSORS AND MEASURING SYSTEMS 2004, 2004, 1829 : 273 - 279
  • [9] CORIOLIS MASS FLOWMETER IS READY FOR THE TOUGH JOBS
    CHIN, W
    I&CS-INSTRUMENTATION & CONTROL SYSTEMS, 1992, 65 (02): : 25 - 27
  • [10] Coriolis Mass Flowmeter selection guide released
    不详
    PIPELINE & GAS JOURNAL, 2002, 229 (10) : 4 - 4