Chest CT Performed with 3D and z-Axis Automatic Tube Current Modulation Technique: Breast and Effective Doses

被引:8
|
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Koshida, Kichiro [1 ]
Noto, Kimiya [2 ]
Shimono, Tetsunori [3 ]
Horii, Junsei [2 ]
Yamamoto, Tomoyuki [2 ]
Matsui, Osamu [4 ]
机构
[1] Kanazawa Univ, Dept Quantum Med Technol, Fac Hlth Sci, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Hoshigaoka Koseinenkin Hosp, Dept Radiol, Hirakata, Osaka, Japan
[4] Kanazawa Univ, Dept Radiol, Fac Med, Kanazawa, Ishikawa 9200942, Japan
关键词
Computed tomography; chests; mammary gland; absorbed dose; effective dose; MULTIDETECTOR-ROW CT; OPTIMIZATION;
D O I
10.1016/j.acra.2008.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Chest computed tomographic (CT) scans are the most effective examinations for detecting lung cancer at ail early stage. In chest CT examinations. it is important to consider the reduction of radiation (lose. particularly to the mammary gland. The objective of this study was to assess breast doses and effective doses oil chest CT examinations between three-dimensional and z-axis automatic tube current modulation (ATCM) techniques. Materials and Methods. Absorbed close to the breast, lung. mediastinum, and skin was evaluated with ail anthropomorphic phantom and radiophotoluminescence glass dosimeters using two different CT scanners. The dosimeters were placed inside and outside the phantom. The phantom was scanned using three-dimensional and z-axis ATCM techniques after scanning localizer radiographs from the horizontal and vertical directions. After scanning, each or-an dose was calculated. Moreover, file dose-length product recorded in the dose reports was examined, and each effective dose was calculated. Results. Compared with z-axis ATCM, three-dimensional ATCM reduced breast dose by 0.7% to 18.6% and effective dose by 4.9% to 10.2%. In particular, three-dimensional ATCM reduced frontal breast dose. For other organs, three-dimensional ATCM reduced absorbed closes by 3.4% to 13.6% compared to Z-axis ATCM. Conclusion. Three-dimensional ATCM call reduce absorbed closes to the breast and other organs, in addition to reducing effective dose, compared to z-axis ATCM.
引用
收藏
页码:450 / 455
页数:6
相关论文
共 50 条
  • [21] Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation
    Saltybaeva, Natalia
    Krauss, Andreas
    Alkadhi, Hatem
    RADIOLOGY, 2017, 282 (03) : 842 - 849
  • [22] Method and phantom to study combined effects of in-plane (x, y) and z-axis resolution for 3D CT imaging
    Goodenough, David
    Levy, Josh
    Kristinsson, Smari
    Fredriksson, Jesper
    Olafsdottir, Hildur
    Healy, Austin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 440 - 452
  • [23] Do we need 3D tube current modulation information for accurate organ dosimetry in chest CT? Protocols dose comparisons
    Xochitl Lopez-Rendon
    Guozhi Zhang
    Walter Coudyzer
    Wim Develter
    Hilde Bosmans
    Federica Zanca
    European Radiology, 2017, 27 : 4490 - 4497
  • [24] Do we need 3D tube current modulation information for accurate organ dosimetry in chest CT? Protocols dose comparisons
    Lopez-Rendon, Xochitl
    Zhang, Guozhi
    Coudyzer, Walter
    Develter, Wim
    Bosmans, Hilde
    Zanca, Federica
    EUROPEAN RADIOLOGY, 2017, 27 (11) : 4490 - 4497
  • [25] Potential for Radiation Dose Savings in Abdominal and Chest CT Using Automatic Tube Voltage Selection in Combination With Automatic Tube Current Modulation
    Mayer, Caroline
    Meyer, Mathias
    Fink, Christian
    Schmidt, Bernhard
    Sedlmair, Martin
    Schoenberg, Stefan O.
    Henzler, Thomas
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : 292 - 299
  • [26] The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging
    Sabah Servaes
    Xiaowei Zhu
    Pediatric Radiology, 2013, 43 : 1287 - 1294
  • [27] The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging
    Servaes, Sabah
    Zhu, Xiaowei
    PEDIATRIC RADIOLOGY, 2013, 43 (10) : 1287 - 1294
  • [28] Straining 3D Hydrogels with Uniform Z-Axis Strains While Enabling Live Microscopy Imaging
    Avishy Roitblat Riba
    Sari Natan
    Avraham Kolel
    Hila Rushkin
    Oren Tchaicheeyan
    Ayelet Lesman
    Annals of Biomedical Engineering, 2020, 48 : 868 - 880
  • [29] Straining 3D Hydrogels with Uniform Z-Axis Strains While Enabling Live Microscopy Imaging
    Riba, Avishy Roitblat
    Natan, Sari
    Kolel, Avraham
    Rushkin, Hila
    Tchaicheeyan, Oren
    Lesman, Ayelet
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (02) : 868 - 880
  • [30] Scanning beyond anatomic limits of the thorax in chest CT: Findings, radiation dose, and automatic tube current modulation
    Campbell, J
    Kalra, MK
    Rizzo, S
    Maher, MM
    Shepard, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) : 1525 - 1530