The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging

被引:0
|
作者
Sabah Servaes
Xiaowei Zhu
机构
[1] The Children’s Hospital of Philadelphia,Department of Radiology
来源
Pediatric Radiology | 2013年 / 43卷
关键词
CT; Radiation dose; Dose reduction; Breast shield; Automatic tube current modulation; Children;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1287 / 1294
页数:7
相关论文
共 50 条
  • [1] The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging
    Servaes, Sabah
    Zhu, Xiaowei
    PEDIATRIC RADIOLOGY, 2013, 43 (10) : 1287 - 1294
  • [2] Effects of tube potential selection together with computed tomography automatic tube current modulation on CT imaging performance
    Sookpeng, S.
    Martin, C. J.
    Krisanachinda, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : 809 - 831
  • [3] Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT
    Leswick, David A.
    Hunt, Megan M.
    Webster, Steven T.
    Fladeland, Derek A.
    RADIOLOGY, 2008, 249 (02) : 572 - 580
  • [4] Radiation Dose Savings for Adult Pulmonary Embolus 64-MDCT Using Bismuth Breast Shields, Lower Peak Kilovoltage, and Automatic Tube Current Modulation
    Hurwitz, Lynne M.
    Yoshizumi, Terry T.
    Goodman, Philip C.
    Nelson, Rendon C.
    Toncheva, Greta
    Nguyen, Giao B.
    Lowry, Carolyn
    Anderson-Evans, Colin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (01) : 244 - 253
  • [5] Techniques and applications of automatic tube current modulation for CT
    Kalra, MK
    Maher, MM
    Toth, TL
    Schmidt, B
    Westerman, BL
    Morgan, HT
    Saini, S
    RADIOLOGY, 2004, 233 (03) : 649 - 657
  • [6] The use of bismuth breast shields for CT should be discouraged
    McCollough, Cynthia H.
    Wang, Jia
    Gould, Robert G.
    Orton, Colin G.
    MEDICAL PHYSICS, 2012, 39 (05) : 2321 - 2324
  • [7] Influence of CT automatic tube current modulation on uncertainty in effective dose
    Sookpeng, S.
    Martin, C. J.
    Gentle, D. J.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (01) : 46 - 54
  • [8] CARDIAC CT DOSE REDUCTION USING BISMUTH BREAST SHIELDS
    Bennett, J.
    McKavanagh, P.
    Doyle, P.
    Ball, P.
    Higginson, D.
    Donnelly, P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S396 - S396
  • [9] Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Yu, Lifeng
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (11) : 6084 - 6092
  • [10] Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT
    Angel, Erin
    Yaghmai, Nazanin
    Jude, Cecilia Matilda
    DeMarco, John J.
    Cagnon, Christopher H.
    Goldin, Jonathan G.
    Primak, Andrew N.
    Stevens, Donna M.
    Cody, Dianna D.
    McCollough, Cynthia H.
    McNitt-Gray, Michael F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (03): : 497 - 511