A Finite Element Analysis Based Sensitivity Studies on Pull Out Strength of Pedicle Screw in Synthetic Osteoporotic Bone Models

被引:0
|
作者
Varghese, Vicky [1 ]
Kumar, G. Saravana [2 ]
Venkatesh, K. [3 ]
机构
[1] IIT Madras, Dept Biotechnol, Madras 600036, Tamil Nadu, India
[2] IIT Madras, Dept Engn Design, Madras 600036, Tamil Nadu, India
[3] Christian Med Coll & Hosp, Dept Orthoped, Spinal Disorders Surg Unit, Vellore 632004, Tamil Nadu, India
关键词
HUMAN SPINE; FIXATION; DESIGN; INSTRUMENTATION; THORACOLUMBAR; VIVO;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pullout strength of pedicle screw is an important index used by surgeon and engineers for design and development of the implant. Increasing pullout strength is difficult since it is dependent on several factors such as density of bone, insertion technique etc. Current study uses a validated 2 D FE model of pullout strength experiment to study the effect of number of threads, inner and outer diameter and thread geometry on holding power of pedicle screw in a synthetic osteoporotic bone model. It was found that outer diameter has highest effect on pullout strength of pedicle screw. Coarser thread provides better holding power in an osteoporotic bone. This study can be used for developing screws with improved holding power in osteoporotic bone.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 50 条
  • [1] Pull out strength of pedicle screw in normal and osteoporotic cancellous bone models
    Varghese, Vicky
    Venkatesh, K.
    Kumar, G. Saravana
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 458 - 463
  • [2] Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models
    Varghese, Vicky
    Kumar, Gurunathan Saravana
    Krishnan, Venkatesh
    MEDICAL ENGINEERING & PHYSICS, 2017, 40 : 28 - 38
  • [3] Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    ASIAN SPINE JOURNAL, 2021, 15 (05) : 566 - 574
  • [4] Influence of novel design alteration of pedicle screw on pull-out strength: A finite element study
    Takenaka, Shota
    Kaito, Takashi
    Ishii, Ken
    Watanabe, Kota
    Watanabe, Kei
    Shinohara, Akira
    Harada, Tomohisa
    Nakada, Fumiya
    Majima, Yusuke
    Matsumoto, Morio
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2020, 25 (01) : 66 - 72
  • [5] Effect of pedicle screw misplacement on the pull-out strength using personalized finite element modeling
    Rouyin, A.
    Nazemi, H.
    Arjmand, N.
    Einafshar, M.J.
    Computers in Biology and Medicine, 2024, 183
  • [6] The benefits of cement augmentation of pedicle screw fixation are increased in Osteoporotic bone: A finite element analysis
    Wang W.
    Baran G.R.
    Garg H.
    Betz R.R.
    Moumene M.
    Cahill P.J.
    Spine Deformity, 2014, 2 (4) : 248 - 259
  • [7] Screw Pullout Strength After Pedicle Screw Reposition: A Finite Element Analysis
    Ye, Yu-Xing
    Huang, Da-Geng
    Hao, Ding-Jun
    Liu, Jia-Yuan
    Ji, Jia-Jia
    Guo, Jin-Niu
    SPINE, 2023, 48 (22) : E382 - E388
  • [8] Biomechanical and finite element analyses of bone cement-Injectable cannulated pedicle screw fixation in osteoporotic bone
    Liu, Yaoyao
    Xu, Jianzhong
    Sun, Dong
    Luo, Fei
    Zhang, Zehua
    Dai, Fei
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2016, 104 (05) : 960 - 967
  • [9] 3D pull-out finite element simulation of the pedicle screw-trabecular bone interface at strain rates
    Cetin, Ahmet
    Bircan, Durmus Ali
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (01) : 134 - 144
  • [10] Investigation of pullout strength in different designs of pedicle screws for osteoporotic bone quality using finite element analysis
    Yang, Shih-Chieh
    Liu, Pao-Hsin
    Tu, Yuan-Kun
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2019, 21 (03) : 57 - 66