Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value

被引:18
|
作者
Mongioi, Laura Maria [1 ]
Condorelli, Rosita Angela [1 ]
Barbagallo, Federica [1 ]
Cannarella, Rossella [1 ]
La Vignera, Sandro [1 ]
Calogero, Aldo Eugenio [1 ]
机构
[1] Univ Catania, Dept Clin & Expt Med, Via S Sofia 78, I-95123 Catania, Italy
关键词
adrenal insufficiency; cortisol levels; low-dose ACTH test stimulation; 1; MU-G; ADRENOCORTICOTROPIN TEST; CORTISOL RESPONSE; AXIS FUNCTION;
D O I
10.3390/jcm8060806
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical practice shows that many low-dose ACTH-stimulation tests have a false positive result. The aim of the study was to determine the diagnostic accuracy of a low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency and to define its optimal cut-off. Methods: We analyzed data from 103 patients undergoing 1 mu g ACTH-stimulation test. Four patients had adrenal insufficiency (AI) upon follow up: Two primary, and two secondary AI. Cortisol serum levels were evaluated at time 0, 20', and 30' after the injection of 1 mu g i.v. of ACTH. The sensitivity, specificity, accuracy, and positive and negative predictive values of the test were calculated for both 20' and 30' sampling. The receiver operating characteristic (ROC) curve was obtained to assess the sensitivity and specificity of low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency at different cut-off values. Results: Considering 500 nmol/L as the standard cut-off value, low-dose ACTH stimulation test showed a 100% sensitivity and a 67.3% specificity, with a high rate of false positive results. ROC curve analysis showed that the cut-off of 401.5 nmol/L is the best compromise between sensitivity (100%) and specificity (93.9%). Conclusions: By using a cut-off value of 401.5 nmol/L for the low-dose ACTH stimulation test, the number of false positive patients decreased significantly, but the sensitivity remained high.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Safety Assessment and Potential Risks of the Glucagon Stimulation Test in the Diagnosis of Secondary Adrenal Insufficiency
    Ach, Taieb
    Ben Abdelkrim, Asma
    Hasni, Yosra
    Saad, Ghada
    Kacem, Maha
    Chaieb, Molka
    Zaouali, Monia
    Maaroufi, Amel
    Ach, Koussay
    CURRENT DRUG SAFETY, 2022, 17 (01) : 59 - 63
  • [42] Diagnosis of adrenal insufficiency in eosinophilic esophagitis: The importance of timing of cortisol measurements in interpreting low-dose adrenocorticotropic hormone stimulation testing
    Schoelwer, Melissa J.
    Nebesio, Todd D.
    JOURNAL OF PEDIATRICS, 2016, 174 : 282 - 282
  • [43] Low-dose (1 μg) adrenocorticotrophin (ACTH) stimulation as a screening test for impaired hypothalamo-pituitary-adrenal axis function:: sensitivity, specificity and accuracy in comparison with the high-dose (250 μg) test
    Tordjman, K
    Jaffe, A
    Trostanetsky, Y
    Greenman, Y
    Limor, R
    Stern, N
    CLINICAL ENDOCRINOLOGY, 2000, 52 (05) : 633 - 640
  • [44] International survey on high- and low-dose synacthen test and assessment of accuracy in preparing low-dose synacthen
    Cross, Alexandra S.
    Kemp, E. Helen
    White, Anne
    Walker, Leanne
    Meredith, Suzanne
    Sachdev, Pooja
    Krone, Nils P.
    Ross, Richard J.
    Wright, Neil P.
    Elder, Charlotte J.
    CLINICAL ENDOCRINOLOGY, 2018, 88 (05) : 744 - 751
  • [45] Low-dose short synacthen test with salivary cortisol in patients with suspected central adrenal insufficiency
    Ceccato, Filippo
    Selmin, Elisa
    Antonelli, Giorgia
    Barbot, Mattia
    Daniele, Andrea
    Boscaro, Marco
    Plebani, Mario
    Scaroni, Carla
    ENDOCRINE CONNECTIONS, 2021, 10 (09) : 1189 - 1199
  • [46] Reproducibility of the low-dose corticotropin (ACTH) stimulation test in ICU patients with sepsis and/or septic shock
    I Dimopoulou
    M Zervou
    E Douka
    C Augustatou
    P Alevizopoulou
    K Stamoulis
    M Theodorakopoulou
    I Mavrou
    M Lignos
    P Kopterides
    E Papadomichelakis
    M Tzoufi
    S Orfanos
    M Tzanela
    A Armaganidis
    S Tsagarakis
    C Roussos
    Critical Care, 10 (Suppl 1):
  • [47] Plasma aldosterone response to the low-dose adrenocorticotrophin (ACTH 1-24) stimulation test
    Honour, J. W.
    Bridges, N. A.
    Conway-Phillips, E.
    Hindmarsh, P. C.
    CLINICAL ENDOCRINOLOGY, 2008, 68 (02) : 299 - 303
  • [48] Salivary cortisol levels by tandem mass spectrometry during high dose ACTH stimulation test for adrenal insufficiency in children
    Chao, Christina S.
    Shi, Run-Zhang
    Kumar, Rajiv B.
    Aye, Tandy
    ENDOCRINE, 2020, 67 (01) : 190 - 197
  • [49] Salivary cortisol levels by tandem mass spectrometry during high dose ACTH stimulation test for adrenal insufficiency in children
    Christina S. Chao
    Run-Zhang Shi
    Rajiv B. Kumar
    Tandy Aye
    Endocrine, 2020, 67 : 190 - 197
  • [50] A comparison of low-dose ACTH, glucagon stimulation and insulin tolerance test in patients with pituitary disorders
    Simsek, Y.
    Karaca, Z.
    Tanriverdi, F.
    Unluhizarci, K.
    Selcuklu, A.
    Kelestimur, F.
    CLINICAL ENDOCRINOLOGY, 2015, 82 (01) : 45 - 52