Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value

被引:18
|
作者
Mongioi, Laura Maria [1 ]
Condorelli, Rosita Angela [1 ]
Barbagallo, Federica [1 ]
Cannarella, Rossella [1 ]
La Vignera, Sandro [1 ]
Calogero, Aldo Eugenio [1 ]
机构
[1] Univ Catania, Dept Clin & Expt Med, Via S Sofia 78, I-95123 Catania, Italy
关键词
adrenal insufficiency; cortisol levels; low-dose ACTH test stimulation; 1; MU-G; ADRENOCORTICOTROPIN TEST; CORTISOL RESPONSE; AXIS FUNCTION;
D O I
10.3390/jcm8060806
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical practice shows that many low-dose ACTH-stimulation tests have a false positive result. The aim of the study was to determine the diagnostic accuracy of a low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency and to define its optimal cut-off. Methods: We analyzed data from 103 patients undergoing 1 mu g ACTH-stimulation test. Four patients had adrenal insufficiency (AI) upon follow up: Two primary, and two secondary AI. Cortisol serum levels were evaluated at time 0, 20', and 30' after the injection of 1 mu g i.v. of ACTH. The sensitivity, specificity, accuracy, and positive and negative predictive values of the test were calculated for both 20' and 30' sampling. The receiver operating characteristic (ROC) curve was obtained to assess the sensitivity and specificity of low-dose ACTH-stimulation test in the diagnosis of adrenal insufficiency at different cut-off values. Results: Considering 500 nmol/L as the standard cut-off value, low-dose ACTH stimulation test showed a 100% sensitivity and a 67.3% specificity, with a high rate of false positive results. ROC curve analysis showed that the cut-off of 401.5 nmol/L is the best compromise between sensitivity (100%) and specificity (93.9%). Conclusions: By using a cut-off value of 401.5 nmol/L for the low-dose ACTH stimulation test, the number of false positive patients decreased significantly, but the sensitivity remained high.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] SALIVARY CORTISOL DETERMINATION AFTER ACTH STIMULATION TEST FOR DIAGNOSIS OF ADRENAL INSUFFICIENCY IN PATIENTS WITH LIVER CIRRHOSIS
    Profitos, J.
    Albert, L.
    Gimenez-Palop, O.
    Vergara, M.
    Dalmau, B.
    Miquel, M.
    Casas, M.
    Capel, I.
    Subias, D.
    Rigla, M.
    Berlanga, E.
    Sanchez, J.
    JOURNAL OF HEPATOLOGY, 2016, 64 : S266 - S267
  • [32] Can a glucagon stimulation test characterized by lower GH cut-off value be used for the diagnosis of growth hormone deficiency in adults?
    Halit Diri
    Zuleyha Karaca
    Yasin Simsek
    Fatih Tanriverdi
    Kursad Unluhizarci
    Ahmet Selcuklu
    Fahrettin Kelestimur
    Pituitary, 2015, 18 : 884 - 892
  • [33] USE OF LOW-DOSE ACTH STIMULATION TO DETECT ACTH INSUFFICIENCY IN A PEDIATRIC POPULATION: IDENTIFYING IDEAL CORTISOL COLLECTION TIMES
    Ramirez, V. A.
    Kinman, R.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (01) : 222 - 222
  • [34] The Low-Dose ACTH Test Does Not Identify Mild Insufficiency of the Hypothalamic-Pituitary-Adrenal Axis in Children with Inadequate Stress Response
    Kamrath, Clemens
    Boehles, Hansjosef
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2010, 23 (11): : 1097 - 1104
  • [35] Can a glucagon stimulation test characterized by lower GH cut-off value be used for the diagnosis of growth hormone deficiency in adults?
    Diri, Halit
    Karaca, Zuleyha
    Simsek, Yasin
    Tanriverdi, Fatih
    Unluhizarci, Kursad
    Selcuklu, Ahmet
    Kelestimur, Fahrettin
    PITUITARY, 2015, 18 (06) : 884 - 892
  • [36] The role of high- and low-dose corticotropin tests in the diagnosis of secondary adrenal insufficiency
    Oelkers, W
    EUROPEAN JOURNAL OF ENDOCRINOLOGY, 1998, 139 (06) : 567 - 570
  • [37] Adrenal status in children with septic shock using low-dose stimulation test
    Sarthi, Manjunatha
    Lodha, Rakesh
    Vivekanandhan, Subbiah
    Arora, Narendra K.
    PEDIATRIC CRITICAL CARE MEDICINE, 2007, 8 (01) : 23 - 28
  • [38] Cut-off value of 50 g glucose challenge test for the diagnosis of gestational diabetes mellitus
    Boriboonhirunsarn, D.
    Lertbunnaphong, T.
    Khanmali, P.
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2012, 28 : 90 - 90
  • [39] Evaluating the Low-Dose ACTH Stimulation Test in Children: Ideal Times for Cortisol Measurement
    Gill, Harpreet
    Barrowman, Nick
    Webster, Richard
    Ahmet, Alexandra
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2019, 104 (10): : 4587 - 4593
  • [40] Evaluating the Low-Dose ACTH Stimulation Test in Neonates: Ideal Times for Cortisol Measurement
    LeDrew, Robyn
    Bariciak, Erika
    Webster, Richard
    Barrowman, Nick
    Ahmet, Alexandra
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2020, 105 (12):