Indoor gamma dose measurements in Gudalore (India) using TLD

被引:15
|
作者
Sivakumar, R [1 ]
Selvasekarapandian, S
Mugunthamanikandan, N
Raghunath, VM
机构
[1] Bharathiar Univ, Dept Phys, Coimbatore 61046, Tamil Nadu, India
[2] Indira Gandhi Ctr Atom Res, Hlth & Safety Div, Kalpakkam 603102, Tamil Nadu, India
关键词
thermoluminescent dosimetry; indoor; dose; external;
D O I
10.1016/S0969-8043(01)00095-1
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO4:Dy thermoluminescent dosimeter for 1 year. Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h (-1) and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 muSv y (-1) for the inhabitants of mud houses to 1406.3 muSv y (-1) for those living in terrace houses made of cement and brick. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:883 / 889
页数:7
相关论文
共 50 条
  • [41] QA measurement of gamma-ray dose and neutron activation using TLD-400 for BNCT beam
    Tsai, Wen-Chyi
    Huang, Chun-Kai
    Jiang, Shiang-Huei
    APPLIED RADIATION AND ISOTOPES, 2018, 137 : 73 - 79
  • [42] MEASUREMENTS OF TERRESTRIAL GAMMA DOSE RATES AND RADON CONCENTRATIONS FROM INDOOR AIR AND WATER IN TRANSYLVANIA REGION
    Dolha, M.
    Timar-Gabor, A.
    Dicu, T.
    Cosma, C.
    ROMANIAN REPORTS IN PHYSICS, 2017, 69 (01)
  • [43] IN VIVO TLD DOSE MEASUREMENTS IN CATHETER-BASED HIGH-DOSE-RATE BRACHYTHERAPY
    Adliene, Diana
    Jakstas, Karolis
    Urbonavicius, Benas Gabrielis
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 477 - 481
  • [44] Surface dose measurement using TLD powder extrapolation
    Rapley, P.
    MEDICAL DOSIMETRY, 2006, 31 (03) : 209 - 215
  • [45] Tumour dose estimation using automated TLD techniques
    Ferguson, HM
    Lambert, GD
    Gustard, D
    Harrison, RM
    ACTA ONCOLOGICA, 1998, 37 (05) : 479 - 484
  • [47] TLD-700 GAMMA-MEASUREMENTS IN MIXED NEUTRON-GAMMA RADIATION-FIELDS
    SIMS, CS
    SWAJA, RE
    RADIATION PROTECTION DOSIMETRY, 1985, 12 (04) : 325 - 331
  • [48] Skin Dose Determination for Photon Beam Breast IMRT Patients Using Monte Carlo Simulations and TLD Measurements
    Yang, J.
    Tong, S.
    Li, J.
    MEDICAL PHYSICS, 2008, 35 (06) : 2798 - +
  • [49] Gamma radiation dose rate in indoor, outdoor and underground atmosphere around Tehri dam project, Uttarakhand, India
    M. S. Negi
    Yogesh Prasad
    Ganesh Prasad
    G. S. Gusain
    Manjari Badoni
    R. C. Ramola
    Indian Journal of Physics, 2009, 83 : 1209 - 1214
  • [50] EFFECT OF BUILDUP FACTORS ON INDOOR GAMMA DOSE RATE
    Manic, V.
    Manic, G.
    Nikezic, D.
    Krstic, D.
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (02) : 132 - 138