Indoor gamma dose measurements in Gudalore (India) using TLD

被引:15
|
作者
Sivakumar, R [1 ]
Selvasekarapandian, S
Mugunthamanikandan, N
Raghunath, VM
机构
[1] Bharathiar Univ, Dept Phys, Coimbatore 61046, Tamil Nadu, India
[2] Indira Gandhi Ctr Atom Res, Hlth & Safety Div, Kalpakkam 603102, Tamil Nadu, India
关键词
thermoluminescent dosimetry; indoor; dose; external;
D O I
10.1016/S0969-8043(01)00095-1
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO4:Dy thermoluminescent dosimeter for 1 year. Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h (-1) and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 muSv y (-1) for the inhabitants of mud houses to 1406.3 muSv y (-1) for those living in terrace houses made of cement and brick. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:883 / 889
页数:7
相关论文
共 50 条
  • [11] Measurements of indoor radon and total gamma dose rate in Portuguese thermal spas
    Silva, A. S.
    Dinis, M. L.
    Pereira, A. J. S. C.
    OCCUPATIONAL SAFETY AND HYGIENE IV, 2016, : 485 - 489
  • [12] TLD extrapolation measurements for entrance and exit dose in radiotherapy
    Kron, T
    Ostwald, PM
    Hamilton, CS
    Denham, JW
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 323 - 326
  • [13] Dose measurements in space by the Hungarian Pille TLD system
    Apáthy, I
    Deme, S
    Fehér, I
    Akatov, YA
    Reitz, G
    Arkhanguelski, VV
    RADIATION MEASUREMENTS, 2002, 35 (05) : 381 - 391
  • [14] Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy
    Kinhikar, Rajesh A.
    Murthy, Vedang
    Goel, Vineeta
    Tambe, Chandrashekar M.
    Dhote, Dipak S.
    Deshpande, Deepak D.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (09) : 1683 - 1685
  • [15] Indoor Gamma Dose Rates In Kuwait Using Handheld Gamma-ray Spectrometer
    Al-Azmi, Darwish
    HEALTH PHYSICS, 2016, 111 (01): : 11 - 16
  • [16] MEASUREMENTS OF GAMMA DOSE AND THERMAL NEUTRON FLUENCE IN PHANTOMS EXPOSED TO A BNCT EPITHERMAL BEAM WITH TLD-700
    Gambarini, G.
    Magni, D.
    Regazzoni, V.
    Borroni, M.
    Carrara, M.
    Pignoli, E.
    Burian, J.
    Marek, M.
    Klupak, V.
    Viererbl, L.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 422 - 427
  • [17] Dose Verification for Accuboost Applicators Using TLD, Ion Chamber and Gafchromic Film Measurements
    Yao, R.
    Dorbu, G.
    MEDICAL PHYSICS, 2014, 41 (06) : 249 - 249
  • [18] Dose measurements in mixed (n,gamma)-radiation fields with TLD's under consideration of the peak height ratio
    Noll, M
    Vana, N
    Schoner, W
    Fugger, M
    Cecil, F
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D380 - D380
  • [19] TLD measurements of the relative output factors for the Leksell Gamma Knife
    Yu, C
    Luxton, G
    Apuzzo, MLJ
    Petrovich, Z
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1999, 72 : 150 - 158
  • [20] Analysis and Recent Advances in Gamma Heating Measurements in MINERVE Facility by Using TLD and OSLD Techniques
    Amharrak, H.
    Di Salvo, J.
    Lyoussi, A.
    Roche, A.
    Masson-Fauchier, M.
    Pepino, A.
    Bosq, J. C.
    Carette, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1360 - 1368