The accuracy of femoral intramedullary guides in total knee arthroplasty

被引:110
|
作者
Reed, SC
Gollish, J
机构
[1] Orthpaedic and Arthritic Hospital, Toronto, Ont.
[2] Orthopaedic and Arthritic Hospital, Toronto, Ont. M4Y 1H1
来源
JOURNAL OF ARTHROPLASTY | 1997年 / 12卷 / 06期
关键词
intramedullary guide; total knee arthroplasty; anatomic axis; entry point;
D O I
10.1016/S0883-5403(97)90141-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Of the technical factors important in achieving a successful total knee arthroplasty, limb alignment has been demonstrated to be most influential in determining implant survival. Intramedullary femoral guide systems rely on placement of the intramedullary rod along the anatomic axis of the femur. Ln this article, the accuracy of the femoral intramedullary guide is investigated using radiographs and a mathematical model. The femoral anatomic axis was drawn on 40 consecutive, preoperative, 3-ft standing radiographs. Using a mathematical model, the potential angular error in the distal femoral cut from aberrant placement of the intramedullary rod was estimated. Calculated values correlated with measured values from plain radiographs and an intramedullary guide template. The anatomic axis was found to exit the distal femur at an average of 6.6 mm medial to the center of the femoral notch. Substantial malalignment error resulted from minor malposition of the intramedullary rod. Most books and diagrams demonstrating the use of intramedullary guides indicate that the entry point is at the center of the femoral notch. These results show that the true entry point is medial to the center of the notch, and rod placement error results in excessive valgus alignment. Preoperative drawing of the anatomic axis on a 3-ft or 18-inch anteroposterior radiograph is recommended. The results both demonstrate the importance of correct use of the guide and heighten cognizance among surgeons performing total knee arthroplasty as to the limitations of the intramedullary guides.
引用
收藏
页码:677 / 682
页数:6
相关论文
共 50 条
  • [31] The femoral sulcus in total knee arthroplasty
    Jean-Yves Jenny
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 415 - 415
  • [32] The femoral sulcus in total knee arthroplasty
    Jenny, Jean-Yves
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (03) : 415 - 415
  • [33] The femoral sulcus in total knee arthroplasty
    Lingaraj, Krishna
    Bartlett, John
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (05) : 499 - 502
  • [34] The femoral sulcus in total knee arthroplasty
    Krishna Lingaraj
    John Bartlett
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 499 - 502
  • [35] Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty
    Günther Maderbacher
    Jan Matussek
    Armin Keshmiri
    Felix Greimel
    Clemens Baier
    Joachim Grifka
    Hermann Maderbacher
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3311 - 3316
  • [36] Automated extraction of the femoral anatomical axis for determining the intramedullary rod parameters in total knee arthroplasty
    Van Cauter, S.
    De Beule, M.
    Van Haver, A.
    Verdonk, P.
    Verhegghe, B.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2012, 28 (01) : 158 - 169
  • [37] Does the intramedullary femoral canal plug reduce blood loss during total knee arthroplasty?
    Yutthana Khanasuk
    Srihatach Ngarmukos
    Aree Tanavalee
    Knee Surgery & Related Research, 34
  • [38] Supracondylar periprosthetic femoral fractures following total knee arthroplasty: treatment with a retrograde intramedullary nail
    Chettiar, K.
    Jackson, M. P.
    Brewin, J.
    Dass, D.
    Butler-Manuel, P. A.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 981 - 985
  • [39] Supracondylar periprosthetic femoral fractures following total knee arthroplasty: treatment with a retrograde intramedullary nail
    K. Chettiar
    M. P. Jackson
    J. Brewin
    D. Dass
    P. A. Butler-Manuel
    International Orthopaedics, 2009, 33
  • [40] KNEE FUSION WITH INTRAMEDULLARY RODS FOR FAILED TOTAL KNEE ARTHROPLASTY
    HARRIS, CM
    FROEHLICH, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1985, (197) : 209 - 216