The accuracy of femoral intramedullary guides in total knee arthroplasty

被引:110
|
作者
Reed, SC
Gollish, J
机构
[1] Orthpaedic and Arthritic Hospital, Toronto, Ont.
[2] Orthopaedic and Arthritic Hospital, Toronto, Ont. M4Y 1H1
来源
JOURNAL OF ARTHROPLASTY | 1997年 / 12卷 / 06期
关键词
intramedullary guide; total knee arthroplasty; anatomic axis; entry point;
D O I
10.1016/S0883-5403(97)90141-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Of the technical factors important in achieving a successful total knee arthroplasty, limb alignment has been demonstrated to be most influential in determining implant survival. Intramedullary femoral guide systems rely on placement of the intramedullary rod along the anatomic axis of the femur. Ln this article, the accuracy of the femoral intramedullary guide is investigated using radiographs and a mathematical model. The femoral anatomic axis was drawn on 40 consecutive, preoperative, 3-ft standing radiographs. Using a mathematical model, the potential angular error in the distal femoral cut from aberrant placement of the intramedullary rod was estimated. Calculated values correlated with measured values from plain radiographs and an intramedullary guide template. The anatomic axis was found to exit the distal femur at an average of 6.6 mm medial to the center of the femoral notch. Substantial malalignment error resulted from minor malposition of the intramedullary rod. Most books and diagrams demonstrating the use of intramedullary guides indicate that the entry point is at the center of the femoral notch. These results show that the true entry point is medial to the center of the notch, and rod placement error results in excessive valgus alignment. Preoperative drawing of the anatomic axis on a 3-ft or 18-inch anteroposterior radiograph is recommended. The results both demonstrate the importance of correct use of the guide and heighten cognizance among surgeons performing total knee arthroplasty as to the limitations of the intramedullary guides.
引用
收藏
页码:677 / 682
页数:6
相关论文
共 50 条
  • [21] Navigation-Assisted Total Knee Arthroplasty for the Knee Retaining Femoral Intramedullary Nail, and Distal Femoral Plate and Screws
    Kim, Kwang-Kyoun
    Heo, Youn-Moo
    Won, Ye-Yeon
    Lee, Woo-Suk
    CLINICS IN ORTHOPEDIC SURGERY, 2011, 3 (01) : 77 - 80
  • [22] Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty
    Ma, B
    Long, W
    Rudan, JF
    Ellis, RE
    JOURNAL OF ARTHROPLASTY, 2006, 21 (02): : 271 - 278
  • [23] INTRAMEDULLARY ARTHRODESIS OF THE KNEE FAILED TOTAL KNEE ARTHROPLASTY
    ELLINGSEN, DE
    RAND, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (06): : 870 - 877
  • [24] Intramedullary total femoral replacement for salvage of the compromised femur associated with hip and knee arthroplasty
    Peters, CL
    Hickman, JM
    Erickson, J
    Lombardi, AV
    Berend, KR
    Mallory, TH
    JOURNAL OF ARTHROPLASTY, 2006, 21 (01): : 53 - 58
  • [25] Improved stability with intramedullary stem after anterior femoral notching in total knee arthroplasty
    Completo, A.
    Fonseca, F.
    Relvas, C.
    Ramos, A.
    Simoes, J. A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 487 - 494
  • [26] Improved stability with intramedullary stem after anterior femoral notching in total knee arthroplasty
    A. Completo
    F. Fonseca
    C. Relvas
    A. Ramos
    J. A. Simões
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 487 - 494
  • [27] Femoral Intramedullary Alignment in Total Knee Arthroplasty: Indications, Results, Pitfalls, Alternatives, and Controversies
    Bono, Olivia J.
    Olcott, Christopher W.
    Carangelo, Robert
    Jamison, James P.
    Tigges, Russell G.
    Talmo, Carl T.
    Bono, James, V
    JOURNAL OF KNEE SURGERY, 2020, 33 (01) : 12 - 14
  • [28] The importance of femoral intramedullary entry point in knee arthroplasty
    Harding, IJ
    Crawford, RW
    Mclardy-Smith, P
    Murray, DW
    KNEE, 1999, 6 (03): : 207 - 210
  • [29] ACCURACY OF INTRAMEDULLARY VERSUS EXTRAMEDULLARY TIBIAL ALIGNMENT CUTTING SYSTEMS IN TOTAL KNEE ARTHROPLASTY
    TETER, KE
    BREGMAN, D
    COLWELL, CW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (321) : 106 - 110
  • [30] Custom cutting guides in total knee arthroplasty
    Chughtai, Morad
    Khlopas, Anton
    Davidson, Iyooh U.
    Yakubek, George A.
    Stearns, Kim L.
    Mont, Michael A.
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (10)