Ultrasound-guided needle insertion robotic system for percutaneous puncture

被引:41
|
作者
Chen, Shihang [1 ]
Wang, Fang [2 ]
Lin, Yanping [1 ]
Shi, Qiusheng [2 ]
Wang, Yanli [3 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Shanghai, Peoples R China
[3] Fudan Univ, Shanghai Canc Ctr, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Minimally invasive surgery; Needle insertion; Percutaneous puncture; Surgical robot assistance; Ultrasound guide;
D O I
10.1007/s11548-020-02300-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Ultrasound (US)-guided percutaneous puncture technology can realize real-time, minimally invasive interventional therapy without radiation. The location accuracy of the puncture needle directly determines the precision and safety of the operation. It is a challenge for novices and young surgeons to perform a free-hand puncture guided by the ultrasound images to achieve the desired accuracy. This work aims to develop a robotic system to assist surgeons to perform percutaneous punctures with high precision. Methods An US-guided puncture robot was designed to allow the mounting and control of the needle to achieve localization and insertion. The US probe fitted within the puncture robot was held by a passive arm. Moreover, the puncture robot was calibrated with a novel calibration method to achieve coordinate transformation between the robot and the US image. The system allowed the operators to plan the puncture target and puncture path on US images, and the robot performed needle insertion automatically. Five groups of puncture experiments were performed to verify the validity and accuracy of the proposed robotic system. Results Assisted by the robotic system, the positioning and orientation accuracies of the needle insertion were 0.9 +/- 0.29 mm and 0.76 +/- 0.34 degrees, respectively. These are improved compared with the results obtained with the free-hand puncture (1.82 +/- 0.51 mm and 2.79 +/- 1.32 degrees, respectively). Moreover, the proposed robotic system can reduce the operation time and number of needle insertions (14.28 +/- 3.21 s and one needle insertion, respectively), compared with the free-hand puncture (25.14 +/- 6.09 s and 1.96 +/- 0.68 needle insertions, respectively). Conclusion A robotic system for percutaneous puncture guided by US images was developed and demonstrated. The experimental results indicate that the proposed system is accurate and feasible. It can assist novices and young surgeons to perform the puncture operation with increased accuracy.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 50 条
  • [31] Robotic system for accurate percutaneous puncture guided by 3D-2D ultrasound
    Lin, Yanping
    Chen, Shihang
    Xu, Wangjie
    Zhu, Xiaoxiao
    Cao, Qixin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (02) : 217 - 225
  • [32] ULTRASOUND-GUIDED PERCUTANEOUS PUNCTURE OF LARGE OVARIAN CYSTS IN 5 NEONATES
    BUNDSCHERER, F
    DEEG, KH
    MONATSSCHRIFT KINDERHEILKUNDE, 1995, 143 (07) : 691 - 695
  • [34] Efficacy of Ultrasound-Guided Percutaneous Needle Treatment of Calcific Tendinitis
    Vignesh, K. Nithin
    McDowall, Adam
    Simunovic, Nicole
    Bhandari, Mohit
    Choudur, Hema N.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : 148 - 152
  • [35] Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses
    Okasha, Hussein Hassan
    Naga, Mazen Ibrahim
    Esmat, Serag
    Naguib, Mohamed
    Hassanein, Mohamed
    Hassani, Mohamed
    El-Kassas, Mohamed
    Mahdy, Reem Ezzat
    El-Gemeie, Emad
    Farag, Ali Hassan
    Foda, Ayman Mohamed
    ENDOSCOPIC ULTRASOUND, 2013, 2 (04) : 190 - 193
  • [36] Examination of endobronchial ultrasound-guided transbronchial needle aspiration using a puncture needle with a side trap
    Kazuhito Miyazaki
    Yuya Hirasawa
    Masaharu Aga
    Naoto Aiko
    Yusuke Hamakawa
    Yuri Taniguchi
    Yuki Misumi
    Yoko Agemi
    Tsuneo Shimokawa
    Hiroyuki Hayashi
    Katsuhiko Naoki
    Hiroaki Okamoto
    Scientific Reports, 11
  • [37] Examination of endobronchial ultrasound-guided transbronchial needle aspiration using a puncture needle with a side trap
    Miyazaki, Kazuhito
    Hirasawa, Yuya
    Aga, Masaharu
    Aiko, Naoto
    Hamakawa, Yusuke
    Taniguchi, Yuri
    Misumi, Yuki
    Agemi, Yoko
    Shimokawa, Tsuneo
    Hayashi, Hiroyuki
    Naoki, Katsuhiko
    Okamoto, Hiroaki
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [38] Ultrasound-guided paravertebral puncture and catheter insertion: an imaging study in human cadavers
    Luyet, C.
    Eichenberger, U.
    Greif, R.
    Moriggl, B.
    SWISS MEDICAL WEEKLY, 2008, 138 (41-42) : 8S - 8S
  • [39] Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game
    Chan, Wing-Yin
    Ni, Dong
    Pang, Wai-Man
    Qin, Jing
    Chui, Yim-Pan
    Yu, Simon Chun-Ho
    Heng, Pheng-Ann
    TRANSACTIONS ON EDUTAINMENT IV, 2010, 6250 : 200 - +
  • [40] Kinematics Data Representations for Skills Assessment in Ultrasound-Guided Needle Insertion
    Liu, Robert
    Holden, Matthew S.
    MEDICAL ULTRASOUND, AND PRETERM, PERINATAL AND PAEDIATRIC IMAGE ANALYSIS, ASMUS 2020, PIPPI 2020, 2020, 12437 : 189 - 198