Ultrasound-guided needle insertion robotic system for percutaneous puncture

被引:41
|
作者
Chen, Shihang [1 ]
Wang, Fang [2 ]
Lin, Yanping [1 ]
Shi, Qiusheng [2 ]
Wang, Yanli [3 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Shanghai, Peoples R China
[3] Fudan Univ, Shanghai Canc Ctr, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Minimally invasive surgery; Needle insertion; Percutaneous puncture; Surgical robot assistance; Ultrasound guide;
D O I
10.1007/s11548-020-02300-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Ultrasound (US)-guided percutaneous puncture technology can realize real-time, minimally invasive interventional therapy without radiation. The location accuracy of the puncture needle directly determines the precision and safety of the operation. It is a challenge for novices and young surgeons to perform a free-hand puncture guided by the ultrasound images to achieve the desired accuracy. This work aims to develop a robotic system to assist surgeons to perform percutaneous punctures with high precision. Methods An US-guided puncture robot was designed to allow the mounting and control of the needle to achieve localization and insertion. The US probe fitted within the puncture robot was held by a passive arm. Moreover, the puncture robot was calibrated with a novel calibration method to achieve coordinate transformation between the robot and the US image. The system allowed the operators to plan the puncture target and puncture path on US images, and the robot performed needle insertion automatically. Five groups of puncture experiments were performed to verify the validity and accuracy of the proposed robotic system. Results Assisted by the robotic system, the positioning and orientation accuracies of the needle insertion were 0.9 +/- 0.29 mm and 0.76 +/- 0.34 degrees, respectively. These are improved compared with the results obtained with the free-hand puncture (1.82 +/- 0.51 mm and 2.79 +/- 1.32 degrees, respectively). Moreover, the proposed robotic system can reduce the operation time and number of needle insertions (14.28 +/- 3.21 s and one needle insertion, respectively), compared with the free-hand puncture (25.14 +/- 6.09 s and 1.96 +/- 0.68 needle insertions, respectively). Conclusion A robotic system for percutaneous puncture guided by US images was developed and demonstrated. The experimental results indicate that the proposed system is accurate and feasible. It can assist novices and young surgeons to perform the puncture operation with increased accuracy.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 50 条
  • [21] Enhancement of needle visibility in ultrasound-guided percutaneous procedures
    Cheung, S
    Rohling, R
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (05): : 617 - 624
  • [22] Percutaneous Nephrolithotomy in Pelvic Kidneys: Is the Ultrasound-guided Puncture Safe?
    Otano, Natalia
    Jairath, Ankush
    Mishra, Shashikant
    Ganpule, Arvind
    Sabnis, Ravindra
    Desai, Mahesh
    UROLOGY, 2015, 85 (01) : 55 - 58
  • [23] ULTRASOUND-GUIDED PERCUTANEOUS FINE NEEDLE PUNCTURE OF RETROPERITONEAL MASS APPEARING AFTER LYMPHADENECTOMY IN TESTICULAR CANCER
    RINGERT, RH
    MEYERSCHWICKERATH, M
    HECKEMANN, R
    EICKENBERG, HU
    AKTUELLE UROLOGIE, 1983, 14 (01) : 11 - 14
  • [24] A Virtual Reality and Haptic Simulator for Ultrasound-Guided Needle Insertion
    Alamilla, Ma Angeles
    Barnouin, Charles
    Moreau, Richard
    Zara, Florence
    Jaillet, Fabrice
    Redarce, Herve Tanneguy
    Coury, Fabienne
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2022, 4 (03): : 634 - 645
  • [25] Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques
    Chu, Carissa
    Masic, Selma
    Usawachintachit, Manint
    Hu, Weiguo
    Yang, Wenzeng
    Stoller, Marshall
    Li, Jianxing
    Chi, Thomas
    JOURNAL OF ENDOUROLOGY, 2016, 30 (02) : 153 - 158
  • [26] Ultrasound-Guided Arterial Puncture
    Haynes, Jeffrey M.
    Mitchell, Holly
    RESPIRATORY CARE, 2010, 55 (12) : 1754 - 1756
  • [27] An efficient needle insertion robotics system for ultrasound-guided hepatic microwave coagulation therapy
    Xu, Jing
    Yang, Xiangdong
    Wu, Dan
    Chen, Ken
    Ren, He
    Liang, Ping
    2007 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS, VOLS 1-6, 2007, : 1258 - +
  • [28] Ultrasound-Guided Lumbar Puncture
    Mints, Gregory
    Bai, Jina
    Wong, Tanping
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (01) : 203 - 203
  • [29] Percutaneous ultrasound-guided insertion of ventriculo-atrial shunts
    McCracken, James Albert
    Bahl, Anuj
    McMullan, John
    BRITISH JOURNAL OF NEUROSURGERY, 2016, 30 (04) : 411 - 413
  • [30] Ultrasound-guided Percutaneous Trucut Needle Biopsy for Musculoskeletal Tumours
    Sallehuddin, A.
    Saw, A.
    George, J.
    Sengupta, S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2008, 2 (01) : 12 - 16