VXD3: The SLD vertex detector upgrade based on a 307 MPixel CCD system

被引:2
|
作者
Brau, JE [1 ]
机构
[1] STANFORD LINEAR ACCELERATOR CTR,STANFORD,CA 94309
基金
美国国家科学基金会;
关键词
D O I
10.1109/23.506646
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The SLD upgrade CCD vertex detector (VXD3) is described. Its 307 million pixels are assembled from 96 3.2 Mpixel CCDs of 13 cm(2) each. The system has evolved from the pioneering CCD vertex detector VXD2, which has operated in SLD since 1992. The CCDs of VXD3 are mounted on beryllium ladders in three cylinders, providing three space point measurements along each track of about 5 microns resolution in all three co-ordinates. Significant improvements are achieved with VXD3 in impact parameter resolution (about a factor of two) and acceptance (similar to 20%) through optimized geometry and reduced material. New readout electronics have been developed for this system.
引用
收藏
页码:1107 / 1112
页数:6
相关论文
共 50 条
  • [41] A system based on an 8-channel analog-to-digital converter for the amplitude analysis of signals from the vertex detector of the SVD-2 setup
    Vasil'ev, MV
    Sen'ko, VA
    Soldatov, MM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2005, 48 (04) : 451 - 454
  • [42] A System Based on an 8-Channel Analog-to-Digital Converter for the Amplitude Analysis of Signals from the Vertex Detector of the SVD-2 Setup
    M. V. Vasil’ev
    V. A. Sen’ko
    M. M. Soldatov
    Instruments and Experimental Techniques, 2005, 48 : 451 - 454
  • [43] A RTR/DR/3D-CT imaging system based on flat panel detector
    Sun Jingjing
    Yang Min
    Fu Jian
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 4207 - 4210
  • [44] Upgrade of the HadGEM3-A based attribution system to high resolution and a new validation framework for probabilistic event attribution
    Ciavarella, Andrew
    Christidis, Nikos
    Andrews, Martin
    Groenendijk, Margriet
    Rostron, John
    Elkington, Mark
    Burke, Claire
    Lott, Fraser C.
    Stott, Peter A.
    WEATHER AND CLIMATE EXTREMES, 2018, 20 : 9 - 32
  • [45] Development of a 3D High-Precise Positioning System Based on a Planar Target and Two CCD Cameras
    Li, Jinjun
    Zhao, Hong
    Jiang, Tao
    Zhou, Xiang
    INTELLIGENT ROBOTICS AND APPLICATIONS, PT II, PROCEEDINGS, 2008, 5315 : 475 - 484
  • [46] Development and Performance of a Multipurpose System for the Environmental Radiation Survey Based on a LaBr3(Ce) Detector
    Ji, Young-Yong
    Lim, Taehyung
    Choi, Hee-Yeoul
    Chung, Kun Ho
    Kang, Mun Ja
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (12) : 2422 - 2429
  • [47] Research on the system error analysis and compensation method for the 3-d profile measurement with CCD based on linear structure lighting
    Ding, J. J.
    Jiang, Z. D.
    Li, B.
    Guo, J. J.
    4th International Symposium on Instrumentation Science and Technology (ISIST' 2006), 2006, 48 : 755 - 760
  • [48] Rapid and automatic 3D body measurement system based on a GPU-Steger line detector
    Liu, Xingjian
    Zhao, Hengshuang
    Zhan, Guomin
    Zhong, Kai
    Li, Zhongwei
    Chao, Yuhjin
    Shi, Yusheng
    APPLIED OPTICS, 2016, 55 (21) : 5539 - 5547
  • [49] Neutron-sensitive ZnS/10B2O3 ceramic scintillator detector as an alternative to a 3He-gas-based detector for a plutonium canister assay system
    Nakamura, T.
    Ohzu, A.
    Toh, K.
    Sakasai, K.
    Suzuki, H.
    Honda, K.
    Birumachi, A.
    Ebine, M.
    Yamagishi, H.
    Takase, M.
    Haruyama, M.
    Kureta, M.
    Soyama, K.
    Nakamura, H.
    Seya, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 : 340 - 346
  • [50] A gas mixture regeneration system for a position-sensitive thermal neutron detector with a 3He-based gas converter
    D. A. Abdushukurov
    Instruments and Experimental Techniques, 2010, 53 : 140 - 142