VXD3: The SLD vertex detector upgrade based on a 307 MPixel CCD system

被引:2
|
作者
Brau, JE [1 ]
机构
[1] STANFORD LINEAR ACCELERATOR CTR,STANFORD,CA 94309
基金
美国国家科学基金会;
关键词
D O I
10.1109/23.506646
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The SLD upgrade CCD vertex detector (VXD3) is described. Its 307 million pixels are assembled from 96 3.2 Mpixel CCDs of 13 cm(2) each. The system has evolved from the pioneering CCD vertex detector VXD2, which has operated in SLD since 1992. The CCDs of VXD3 are mounted on beryllium ladders in three cylinders, providing three space point measurements along each track of about 5 microns resolution in all three co-ordinates. Significant improvements are achieved with VXD3 in impact parameter resolution (about a factor of two) and acceptance (similar to 20%) through optimized geometry and reduced material. New readout electronics have been developed for this system.
引用
收藏
页码:1107 / 1112
页数:6
相关论文
共 50 条
  • [31] AN AREA X-RAY-DETECTOR SYSTEM BASED ON A COMMERCIALLY AVAILABLE CCD-UNIT
    FUCHS, HF
    QU, DQ
    CHU, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (02): : 712 - 716
  • [32] Neural Network-Based Primary Vertex Reconstruction with FPGAs for the Upgrade of the CMS Level-1 Trigger System
    Brown, C.
    Bundock, A.
    Komm, M.
    Loncar, V.
    Pierini, M.
    Radburn-Smith, B.
    Shtipliyski, A.
    Summers, S.
    Dancu, J. -S.
    Tapper, A.
    20TH INTERNATIONAL WORKSHOP ON ADVANCED COMPUTING AND ANALYSIS TECHNIQUES IN PHYSICS RESEARCH, 2023, 2438
  • [33] Characteristics of a dual-detector charge coupled device (CCD) based optical fluorescence imaging system
    Chen, Jason Y.
    Li, Yuhua
    Liu, Hong
    COMPLEX DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS III, 2006, 6085
  • [34] Characterization of a digital x-ray imaging system for small animal studies based on CCD detector
    Ye, C
    Luo, QM
    Zhong, AJ
    Liang, WX
    PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 228 - 233
  • [35] FPGA-based algorithms for the new trigger system for the phase 2 upgrade of the CMS drift tubes detector
    Cela-Ruiz, J. -M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [36] Towards a high performance vertex detector based on 3D integration of deep N-well MAPS
    Re, V.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [37] ALICE ITS3: A truly cylindrical vertex detector based on bent, wafer-scale stitched CMOS sensors
    Liu, Jian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [38] Attitude Correction Algorithm for a Vehicular 3-Axis Stabilized Tracking System Based on CCD
    Liu Zhigang
    Wang Junzheng
    Zhao Jiangbo
    PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 3, 2008, : 370 - 373
  • [39] Design of an on-line monitoring system based on a 3He detector
    Ghavami, Ahad
    Tajik, Mojtaba
    APPLIED RADIATION AND ISOTOPES, 2022, 188
  • [40] In-orbit geometric calibration and validation of ZY-3 three-line cameras based on CCD-detector look angles
    Cao, Jinshan
    Yuan, Xiuxiao
    Gong, Jianya
    PHOTOGRAMMETRIC RECORD, 2015, 30 (150): : 211 - 226