Electrical Source Imaging in Freely Moving Rats: Evaluation of a 12-Electrode Cortical Electroencephalography System

被引:4
|
作者
Jiricek, Stanislav [1 ,2 ,3 ]
Koudelka, Vlastimil [1 ]
Lacik, Jaroslav [4 ]
Vejmola, Cestmir [1 ,5 ]
Kuratko, David [4 ]
Wojcik, Daniel K. [4 ,6 ]
Raida, Zbynek [4 ]
Hlinka, Jaroslav [1 ,3 ]
Palenicek, Tomas [1 ,5 ]
机构
[1] Natl Inst Mental Hlth, Klecany, Czech Republic
[2] Czech Tech Univ, Dept Cybernet, Fac Elect Engn, Prague, Czech Republic
[3] Czech Acad Sci, Dept Complex Syst, Inst Comp Sci, Prague, Czech Republic
[4] Brno Univ Technol, Fac Elect Engn & Commun, Dept Radioengn, Brno, Czech Republic
[5] Charles Univ Prague, Fac Med 3, Prague, Czech Republic
[6] Polish Acad Sci, Nencki Inst Expt Biol, Lab Neuroinformat, Warsaw, Poland
关键词
electroencephalography; preclinical models; electrical source imaging; translational research; auditory steady-state response experiment; fieldtrip; EEG;
D O I
10.3389/fninf.2020.589228
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This work presents and evaluates a 12-electrode intracranial electroencephalography system developed at the National Institute of Mental Health (Klecany, Czech Republic) in terms of an electrical source imaging (ESI) technique in rats. The electrode system was originally designed for translational research purposes. This study demonstrates that it is also possible to use this well-established system for ESI, and estimates its precision, accuracy, and limitations. Furthermore, this paper sets a methodological basis for future implants. Source localization quality is evaluated using three approaches based on surrogate data, physical phantom measurements, and in vivo experiments. The forward model for source localization is obtained from the FieldTrip-SimBio pipeline using the finite-element method. Rat brain tissue extracted from a magnetic resonance imaging template is approximated by a single-compartment homogeneous tetrahedral head model. Four inverse solvers were tested: standardized low-resolution brain electromagnetic tomography, exact low-resolution brain electromagnetic tomography (eLORETA), linear constrained minimum variance (LCMV), and dynamic imaging of coherent sources. Based on surrogate data, this paper evaluates the accuracy and precision of all solvers within the brain volume using error distance and reliability maps. The mean error distance over the whole brain was found to be the lowest in the eLORETA solution through signal to noise ratios (SNRs) (0.2 mm for 25 dB SNR). The LCMV outperformed eLORETA under higher SNR conditions, and exhibiting higher spatial precision. Both of these inverse solvers provided accurate results in a phantom experiment (1.6 mm mean error distance across shallow and 2.6 mm across subcortical testing dipoles). Utilizing the developed technique in freely moving rats, an auditory steady-state response experiment provided results in line with previously reported findings. The obtained results support the idea of utilizing a 12-electrode system for ESI and using it as a solid basis for the development of future ESI dedicated implants.
引用
收藏
页数:22
相关论文
共 13 条
  • [1] Design of data acquisition system for 12-electrode electrical capacitance tomography
    Sheng, Liu
    Shen, Yijian
    Zheng, Guibin
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS, 2007, : 2293 - +
  • [2] A multichannel system for recording and analysis of cortical field potentials in freely moving rats
    Shaw, FZ
    Chen, RF
    Tsao, HW
    Yen, CT
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1999, 88 (01) : 33 - 43
  • [3] Electrical Source Imaging in Rats: Cortical EEG Performance and Limitations
    Koudelka, Vlastimil
    Jiricek, Stanislav
    Piorecka, Vaclava
    Vejmola, Cestmir
    Palenicek, Tomas
    Raida, Zbynek
    Lacik, Jaroslav
    Kuratko, David
    Wojcik, Daniel
    Brunovsky, Martin
    [J]. 2018 INTERNATIONAL WORKSHOP ON COMPUTING, ELECTROMAGNETICS, AND MACHINE INTELLIGENCE (CEMI), 2018, : 45 - 46
  • [4] Evaluation of cutaneous allodynia following induction of cortical spreading depression in freely moving rats
    Fioravanti, Beatriz
    Kasasbeh, Aimen
    Edelmayer, Rebecca
    Skinner, David P., Jr.
    Hartings, Jed A.
    Burklund, Ryan D.
    De Felice, Milena
    French, Edward D.
    Dussor, Greg O.
    Dodick, David W.
    Porreca, Frank
    Vanderah, Todd W.
    [J]. CEPHALALGIA, 2011, 31 (10) : 1090 - 1100
  • [5] Miniaturized Neural Observation System for in vivo Brain Imaging in Freely Moving Rats
    Siwadamrongpong, Ronnakorn
    Sunaga, Yoshinori
    Sasagawa, Kiyotaka
    Ohta, Yasumi
    Takehara, Hironari
    Haruta, Makito
    Tashiro, Hiroyuki
    Ohta, Jun
    [J]. SENSORS AND MATERIALS, 2023, 35 (09) : 3227 - 3239
  • [6] An Image Reconstruction Algorithm for a 12-Electrode Capacitively Coupled Electrical Resistance Tomography System Under 2-Electrode Excitation Strategy
    Xu, Zhen
    Huang, Junchao
    Jiang, Yandan
    Wang, Baoliang
    Huang, Zhiyao
    Soleimani, Manuchehr
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [7] Three-photon head-mounted microscope for imaging deep cortical layers in freely moving rats
    Alexandr Klioutchnikov
    Damian J. Wallace
    Michael H. Frosz
    Richard Zeltner
    Juergen Sawinski
    Verena Pawlak
    Kay-Michael Voit
    Philip St. J. Russell
    Jason N. D. Kerr
    [J]. Nature Methods, 2020, 17 : 509 - 513
  • [8] Three-photon head-mounted microscope for imaging deep cortical layers in freely moving rats
    Klioutchnikov, Alexandr
    Wallace, Damian J.
    Frosz, Michael H.
    Zeltner, Richard
    Sawinski, Juergen
    Pawlak, Verena
    Voit, Kay-Michael
    Russell, Philip St. J.
    Kerr, Jason N. D.
    [J]. NATURE METHODS, 2020, 17 (05) : 509 - +
  • [9] Extendable, miniaturized multi-modal optical imaging system: cortical hemodynamic observation in freely moving animals
    Liu, Rui
    Huang, Qin
    Li, Bing
    Yin, Cui
    Jiang, Chao
    Wang, Jia
    Lu, Jinling
    Luo, Qingmin
    Li, Pengcheng
    [J]. OPTICS EXPRESS, 2013, 21 (02): : 1911 - 1924
  • [10] Electrodermal response in nonglabrous skin of freely moving rats: Mediation by the sympathetic nervous system and evaluation in an animal model of depression
    Guinjoan, SM
    Yannielli, PC
    Lococco, J
    Siri, LN
    Cardinali, DP
    [J]. NEUROPSYCHOBIOLOGY, 1996, 33 (03) : 147 - 154