Sensitivity-encoded coronary MRA at 3T

被引:4
|
作者
Huber, ME
Kozerke, S
Pruessmann, KP
Smink, J
Boesiger, P
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, Zurich, Switzerland
关键词
coronary MRA; high field; 3T; sensitivity encoding; parallel imaging;
D O I
10.1002/MRM.20062
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Long scan times are still a main limitation in free-breathing navigator-gated 3D coronary MR angiography (MRA). Unlike other MRI applications, high-resolution coronary MRA has not been amenable to acceleration by parallel imaging techniques due to signal-to-noise ratio (SNR) concerns. In the present work, mitigating SNR limitations by the transition to higher static magnetic field strength is proposed, thus enabling scan time reduction by the parallel sensitivity encoding (SENSE) technique. The study reports the implementation and evaluation of free-breathing navigator-gated 3D coronary MRA with SENSE at 3T. Results from 11 healthy subjects indicate that the approach permits significant scan time reduction in MRA of the left and right coronary systems. Quantitative image analysis and visual grading suggest that two-fold scan acceleration can be accomplished at nearly preserved image quality. The additional experiments appear to demonstrate that parallel MRA equally permits enhancing volume coverage and spatial resolution while maintaining scan time. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [31] Improved image reconstruction from sensitivity-encoded data by wavelet denoising and Tikhonov regularization
    Liang, ZP
    Bammer, R
    Ji, J
    Pelc, NJ
    Glover, GH
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 493 - 496
  • [32] A clinical strategy to improve the diagnostic performance of 3T non-contrast coronary MRA and noninvasively evaluate coronary distensibility: combination of diastole and systole imaging
    Lu, Hongfei
    Zhao, Shihai
    Tian, Di
    Chen, Yinyin
    Ma, Jianying
    Ge, Meiying
    Zeng, Mengsu
    Jin, Hang
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [33] A clinical strategy to improve the diagnostic performance of 3T non-contrast coronary MRA and noninvasively evaluate coronary distensibility: combination of diastole and systole imaging
    Hongfei Lu
    Shihai Zhao
    Di Tian
    Yinyin Chen
    Jianying Ma
    Meiying Ge
    Mengsu Zeng
    Hang Jin
    Journal of Cardiovascular Magnetic Resonance, 25
  • [34] Acceleration of tissue phase mapping with sensitivity encoding at 3T
    Anja Lutz
    Axel Bornstedt
    Robert Manzke
    Patrick Etyngier
    G Ulrich Nienhaus
    Wolfgang Rottbauer
    Volker Rasche
    Journal of Cardiovascular Magnetic Resonance, 13
  • [35] MRA of intracranial aneurysms embolized with platinum coils: A vascular phantom study at 1.5T and 3T
    Kakeda, Shingo
    Korogi, Yukunori
    Hiai, Yasuhiro
    Sato, Toru
    Ohnari, Norihiro
    Moriya, Junji
    Kamada, Koji
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) : 13 - 20
  • [36] Acceleration of tissue phase mapping with sensitivity encoding at 3T
    Lutz, Anja
    Bornstedt, Axel
    Manzke, Robert
    Etyngier, Patrick
    Nienhaus, G. Ulrich
    Rottbauer, Wolfgang
    Rasche, Volker
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [37] Sensitivity-encoded (SENSE) proton echo-planar spectroscopic imaging (PEPSI) in the human brain
    Lin, Fa-Hsuan
    Tsai, Shang-Yueh
    Otazo, Ricardo
    Caprihan, Arvind
    Wald, Lawrence L.
    Belliveau, John W.
    Posse, Stefan
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) : 249 - 257
  • [38] 大孔径3T低剂量下肢动脉MRA的临床研究
    李丹
    邓克学
    林江
    安徽医科大学学报, 2015, 50 (09) : 1333 - 1336
  • [39] Peak velocity and flow quantification validation for sensitivity-encoded phase-contrast MR imaging
    Lew, Calvin D.
    Alley, Marcus T.
    Bammer, Roland
    Spielman, Daniel M.
    Chan, Frandics P.
    ACADEMIC RADIOLOGY, 2007, 14 (03) : 258 - 269
  • [40] Sensitivity-encoded single-shot spiral imaging for reduced susceptibility artifacts in BOLD fMRI
    Weiger, M
    Pruessmann, KP
    Österbauer, R
    Börnert, P
    Boesiger, P
    Jezzard, P
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) : 860 - 866