Sensitivity-encoded coronary MRA at 3T

被引:4
|
作者
Huber, ME
Kozerke, S
Pruessmann, KP
Smink, J
Boesiger, P
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, Zurich, Switzerland
关键词
coronary MRA; high field; 3T; sensitivity encoding; parallel imaging;
D O I
10.1002/MRM.20062
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Long scan times are still a main limitation in free-breathing navigator-gated 3D coronary MR angiography (MRA). Unlike other MRI applications, high-resolution coronary MRA has not been amenable to acceleration by parallel imaging techniques due to signal-to-noise ratio (SNR) concerns. In the present work, mitigating SNR limitations by the transition to higher static magnetic field strength is proposed, thus enabling scan time reduction by the parallel sensitivity encoding (SENSE) technique. The study reports the implementation and evaluation of free-breathing navigator-gated 3D coronary MRA with SENSE at 3T. Results from 11 healthy subjects indicate that the approach permits significant scan time reduction in MRA of the left and right coronary systems. Quantitative image analysis and visual grading suggest that two-fold scan acceleration can be accomplished at nearly preserved image quality. The additional experiments appear to demonstrate that parallel MRA equally permits enhancing volume coverage and spatial resolution while maintaining scan time. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [21] Fat Signal Suppression for Coronary MRA at 3T Using a Water-Selective Adiabatic T2-Preparation Technique
    Coristine, Andrew J.
    van Heeswijk, Ruud B.
    Stuber, Matthias
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 763 - 769
  • [22] 脊髓血管疾病3T动态MR血管成像(MRA)
    M.I.Vargas
    D.Nguyen
    M.Viallon
    Z.Kulcsár
    E.Tessitore
    B.Rilliet
    董潇蔓
    国际医学放射学杂志, 2010, 33 (06) : 594 - 594
  • [23] Improved fat signal suppression for coronary MRA at 3T using a water-selective adiabatic T2-Prep technique
    Andrew J Coristine
    Ruud B van Heeswijk
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [24] Evaluation of the diagnostic performance of self-navigated whole-heart contrast-enhanced coronary MRA at 3T
    Yi He
    Jianing Pang
    Zhanming Fan
    Jing An
    Tianjing Zhang
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [25] Motion corrected sensitivity encoded isotropic projection reconstruction (SNIPR) for whole-heart coronary MRA
    Jianing Pang
    Behzad Sharif
    Reza Arsanjani
    Louise E Thomson
    John D Friedman
    Daniel S Berman
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [26] 3T contrast-enhanced whole heart coronary MRA using 32-channel cardiac coils for the detection of coronary artery disease
    Qi Yang
    Kuncheng Li
    Xiaoming Bi
    Jing An
    Renate Jerecic
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [27] Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)
    Preibisch, C
    Pilatus, U
    Bunke, R
    Hoogenraad, F
    Zanella, F
    Lanfermann, H
    NEUROIMAGE, 2003, 19 (02) : 412 - 421
  • [28] Faster flow quantification using sensitivity-encoded phase contrast magnetic resonance imaging
    Prakash, A
    Garg, R
    Marcus, EN
    Reynolds, G
    Geva, T
    Powell, AJ
    CIRCULATION, 2004, 110 (17) : 387 - 388
  • [29] Comparison of 3D TOF-MRA and 3D CE-MRA at 3T for imaging of intracranial aneurysms
    Cirillo, Mario
    Scomazzoni, Francesco
    Cirillo, Luigi
    Cadioli, Marcello
    Simionato, Franco
    Iadanza, Antonella
    Kirchin, Miles
    Righi, Claudio
    Anzalone, Nicoletta
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : E853 - E859
  • [30] 3T TOF MRA与DSA评价颅内动脉系统
    毛群
    张鹤
    江苏医药, 2011, 37 (01) : 98 - 101