Performance and long-term consistency of five Galliform 68Ge/68Ga generators used for clinical Ga-68 preparations over a 4 year period

被引:3
|
作者
Sammartano, Antonino [1 ]
Migliari, Silvia [1 ]
Scarlattei, Maura [1 ]
Baldari, Giorgio [1 ]
Serreli, Giulio [2 ]
Lazzara, Chiara [1 ]
Garau, Ludovico [1 ]
Ghetti, Caterina [2 ]
Ruffini, Livia [1 ]
机构
[1] Azienda Osped Univ Parma, Div Nucl Med, Diagnost Dept, Via Gramsci 14, I-43126 Parma, Italy
[2] Azienda Osped Univ Parma, Diagnost Dept, Med Phys Unit, Parma, Italy
关键词
68Ga-radiopharmaceuticals; 68Ge; 68Ga generator; radiochemical purity; RADIOPHARMACEUTICALS; VALIDATION; FUTURE;
D O I
10.1097/MNM.0000000000001545
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Gallium-68 is a positron emitter for PET applications that can be produced without cyclotron by a germanium (Ge-68) chloride/gallium (Ga-68) chloride generator. Short half-life (67.71 min) of Ga-68, matching pharmacokinetic properties of small biomolecules, facilitates isotope utilization in compounding radiopharmaceuticals for PET imaging. The increasing cost of good manufacturing practice-compliant generators has strengthened the need for radionuclide efficient use by planning specific radiopharmaceutical sessions during the week, careful maintenance of the generator and achievement of high labeling yield and radiochemical purity (RCP) of the radiolabeled molecules. Methods The aim of this study was to evaluate the annual performance of five consecutive Ge-68/Ga-68 generators used for small-scale preparations of 68Ga-radiopharmaceuticals. To assess the long-term efficiency of isotope production we measured the weekly elution yield. To assess process efficiency we measured elution yield, labeling yield and RCP of four radiopharmaceutical preparations (Ga-68-DOTATOC, Ga-68-PSMA-HBED-CC, Ga-68-PENTIXAFOR and Ga-68-DOTATATE). Results The annual mean elution yield of the generators was 74.7%, higher than that indicated by the manufacturer, and it never went below 65%. The Ge-68 level in the final products was under the detection limits in all the produced batches (mean value 0.0000048%). The RCP of radiopharmaceuticals determined by high-performance liquid chromatography was 98 +/- 0.22%. The mean yield of radiolabelling was 64.68, 68.71, 57 and 63.68% for Ga-68-DOTATOC, Ga-68-PSMA-HBED-CC, (68)GaPENTIXAFOR and Ga-68-DOTATATE. Conclusion The ability to prepare in the hospital radiopharmacy high-purity and pharmaceutically acceptable Ga-68-radiolabeled probes on a routine basis facilitates patient access to precision imaging for clinical and research aims.
引用
收藏
页码:568 / 576
页数:9
相关论文
共 50 条
  • [31] Impact of elution impurities on DOTA and NOTA labeling with two commercial 68Ge/68Ga generators
    Amor-Coarasa, Alejandro
    Gruca, Monika
    Hurez, Sophie
    Gulec, Seza A.
    McGoron, Anthony
    Babich, John W.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 317 (03) : 1485 - 1490
  • [32] Efficient and reliable manufacture of 68Ga-radiopharmaceuticals using up to four 68Ge/68Ga generators in series and the Scintomics GRP module
    Bourdier, Thomas
    Henderson, David
    Poon, Jackson
    Lam, Peter
    Vu Le
    Brackenreg, Jodie
    Katsifis, Andrew
    Fulham, Micheal J.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2017, 60 : S391 - S391
  • [33] Optimization of Automated Radiosynthesis of Gallium-68-Labeled PSMA11 with Two [68Ge]Ge/[68Ga]Ga Generators: Fractional Elution or Prepurification?
    Durieux, Flore
    Dekyndt, Berengere
    Legrand, Jean-Francois
    Rogeau, Antoine
    Malek, Emmanuel
    Semah, Franck
    Odou, Pascal
    Benesova-Schaefer, Martina
    PHARMACEUTICALS, 2023, 16 (11)
  • [34] Comprehensive Quality Control of the ITG 68Ge/68Ga Generator and Synthesis of 68Ga-DOTATOC and 68Ga-PSMA-HBED-CC for Clinical Imaging
    Amor-Coarasa, Alejandro
    Sehoendorf, Megan
    Meckel, Marian
    Vallabhajosula, Shankar
    Babich, John W.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (09) : 1402 - 1405
  • [35] [68Ga]Ga-PSMA: An evaluation between the direct elution and preconcentration method using dual Eckert & Ziegler 68Ge/68Ga generators on the iPhase MultiSyn radiosynthesiser
    Nguyen, B.
    Kocovski, P.
    Ackermann, U.
    Scott, A. M.
    INTERNAL MEDICINE JOURNAL, 2022, 52 : 34 - 35
  • [36] Performance appraisal of acid resistant novel candidate for 68Ge/68Ga generator system
    Lee, Jun Young
    Park, Jeong Hoon
    Hur, Min Goo
    Yang, Seung Dae
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2017, 60 : S630 - S630
  • [37] Clinical experience with indigenous kit-based preparation of 68Ga-DOTATOC using commercial 68Ge/68Ga generator
    Pandey, Usha
    Korde, Aruna
    Mukherjee, Archana
    Shinto, Ajit
    Kamaleswaran, K. K.
    Jose, Raghi P.
    Gamre, Naresh
    Dash, Ashutosh
    APPLIED RADIATION AND ISOTOPES, 2018, 136 : 59 - 64
  • [38] Standardization of 68Ge/68Ga using the 4πβ - γ coincidence method based on Cherenkov counting
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 252 - 256
  • [39] Performance evaluation for stable adsorbent in acidic eluent as a 68Ge/68Ga generator column material
    Lee, J.
    Park, J.
    Hur, M.
    Yang, S.
    Yu, K.
    Kim, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S454 - S454
  • [40] Continuation of comprehensive quality control of the itG 68Ge/68Ga generator and production of 68Ga-DOTATOC and 68Ga-PSMA-HBED-CC for clinical research studies
    Amor-Coarasa, Alejandro
    Kelly, James M.
    Gruca, Monika
    Nikolopoulou, Anastasia
    Vallabhajosula, Shankar
    Babich, John W.
    NUCLEAR MEDICINE AND BIOLOGY, 2017, 53 : 37 - 39