Performance and long-term consistency of five Galliform 68Ge/68Ga generators used for clinical Ga-68 preparations over a 4 year period

被引:3
|
作者
Sammartano, Antonino [1 ]
Migliari, Silvia [1 ]
Scarlattei, Maura [1 ]
Baldari, Giorgio [1 ]
Serreli, Giulio [2 ]
Lazzara, Chiara [1 ]
Garau, Ludovico [1 ]
Ghetti, Caterina [2 ]
Ruffini, Livia [1 ]
机构
[1] Azienda Osped Univ Parma, Div Nucl Med, Diagnost Dept, Via Gramsci 14, I-43126 Parma, Italy
[2] Azienda Osped Univ Parma, Diagnost Dept, Med Phys Unit, Parma, Italy
关键词
68Ga-radiopharmaceuticals; 68Ge; 68Ga generator; radiochemical purity; RADIOPHARMACEUTICALS; VALIDATION; FUTURE;
D O I
10.1097/MNM.0000000000001545
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Gallium-68 is a positron emitter for PET applications that can be produced without cyclotron by a germanium (Ge-68) chloride/gallium (Ga-68) chloride generator. Short half-life (67.71 min) of Ga-68, matching pharmacokinetic properties of small biomolecules, facilitates isotope utilization in compounding radiopharmaceuticals for PET imaging. The increasing cost of good manufacturing practice-compliant generators has strengthened the need for radionuclide efficient use by planning specific radiopharmaceutical sessions during the week, careful maintenance of the generator and achievement of high labeling yield and radiochemical purity (RCP) of the radiolabeled molecules. Methods The aim of this study was to evaluate the annual performance of five consecutive Ge-68/Ga-68 generators used for small-scale preparations of 68Ga-radiopharmaceuticals. To assess the long-term efficiency of isotope production we measured the weekly elution yield. To assess process efficiency we measured elution yield, labeling yield and RCP of four radiopharmaceutical preparations (Ga-68-DOTATOC, Ga-68-PSMA-HBED-CC, Ga-68-PENTIXAFOR and Ga-68-DOTATATE). Results The annual mean elution yield of the generators was 74.7%, higher than that indicated by the manufacturer, and it never went below 65%. The Ge-68 level in the final products was under the detection limits in all the produced batches (mean value 0.0000048%). The RCP of radiopharmaceuticals determined by high-performance liquid chromatography was 98 +/- 0.22%. The mean yield of radiolabelling was 64.68, 68.71, 57 and 63.68% for Ga-68-DOTATOC, Ga-68-PSMA-HBED-CC, (68)GaPENTIXAFOR and Ga-68-DOTATATE. Conclusion The ability to prepare in the hospital radiopharmacy high-purity and pharmaceutically acceptable Ga-68-radiolabeled probes on a routine basis facilitates patient access to precision imaging for clinical and research aims.
引用
收藏
页码:568 / 576
页数:9
相关论文
共 50 条
  • [21] Acid resistant zirconium phosphate for the long term application of 68Ge/68Ga generator system
    Lee, Jun Young
    Vyas, Chirag K.
    Kim, Bo-Ram
    Kim, Hee Jung
    Hur, Min Goo
    Yang, Seung Dae
    Park, Jeong Hoon
    Kim, Sang Wook
    APPLIED RADIATION AND ISOTOPES, 2016, 118 : 343 - 349
  • [22] Validation of 68Ge/68Ga generator processing by chemical purification for routine clinical application of 68Ga-DOTATOC
    Asti, Mattia
    De Pietri, Giovanni
    Fraternali, Alessandro
    Grassi, Elisa
    Sghedoni, Roberto
    Floroni, Federica
    Roesch, Frank
    Versari, Annibale
    Salvo, Diana
    NUCLEAR MEDICINE AND BIOLOGY, 2008, 35 (06) : 721 - 724
  • [23] 68Ge/68Ga Generator Use in Clinical Productions: Effect of Elution Frequency
    Fulcher, C.
    INTERNAL MEDICINE JOURNAL, 2022, 52 : 53 - 53
  • [24] Extending the life of SnO2 68Ge/68Ga generators used in the radiolabelling of ion exchange resins
    van Heerden, M. R.
    Cole, K.
    van der Meulen, N. P.
    Franzidis, J. -P.
    Buffler, A.
    APPLIED RADIATION AND ISOTOPES, 2020, 158
  • [25] Activity determination of 68Ge/68Ga by means of 4πβ(sic)-γ coincidence counting
    Marganiec-Galazka, Justyna
    Naehle, Ole J.
    Kossert, Karsten
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 240 - 244
  • [26] Kit-based preparation of [68Ga]Ga-P16-093 (PSMA-093) using different commercial 68Ge/68Ga generators
    Hong, Haiyan
    Wang, Guochang
    Ploessl, Karl
    Zha, Zhihao
    Zang, Jie
    Zhu, Zhaohui
    Zhu, Lin
    Kung, Hank F.
    NUCLEAR MEDICINE AND BIOLOGY, 2022, 106 : 1 - 9
  • [27] Optimization of a Labeling and Kit Preparation Method for Ga-68 Labeled DOTATATE, Using Cation Exchange Resin Purified Ga-68 Eluates Obtained from a Tin Dioxide 68Ge/68Ga Generator
    Deidré Prince
    Daniel Rossouw
    Sietske Rubow
    Molecular Imaging and Biology, 2018, 20 : 1008 - 1014
  • [28] Optimization of a Labeling and Kit Preparation Method for Ga-68 Labeled DOTATATE, Using Cation Exchange Resin Purified Ga-68 Eluates Obtained from a Tin Dioxide 68Ge/68Ga Generator
    Prince, Deidre
    Rossouw, Daniel
    Rubow, Sietske
    MOLECULAR IMAGING AND BIOLOGY, 2018, 20 (06) : 1008 - 1014
  • [29] Impact of elution impurities on DOTA and NOTA labeling with two commercial 68Ge/68Ga generators
    Alejandro Amor-Coarasa
    Monika Gruca
    Sophie Hurez
    Seza A. Gulec
    Anthony McGoron
    John W. Babich
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 317 : 1485 - 1490
  • [30] Long-Term Evaluation of 'BARC 68Ge/68Ga Generator' Based on the Nanoceria-Polyacrylonitrile Composite Sorbent
    Chakravarty, Rubel
    Chakraborty, Sudipta
    Ram, Ramu
    Dash, Ashutosh
    Pillai, M. R. A.
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2013, 28 (08) : 631 - 637