Detection of architectural distortion in mammograms using geometrical properties of thinned edge structures

被引:4
|
作者
Lakshmanan, Rekha [1 ]
Shiji, T. P. [1 ]
Jacob, Suma Mariam [2 ]
Pratab, Thara [2 ]
Thomas, Chinchu [3 ]
Thomas, Vinu [1 ]
机构
[1] Govt Model Engn Coll, Dept Elect Engn, Kochi, Kerala, India
[2] Lakeshore Hosp, Kochi, India
[3] Govt Engn Coll, Dept Elect Engn, Cherthala, India
来源
关键词
Architectural distortion; breast cancer; classification; cuckoo search; geometrical properties of edge; structures; mammogram; pectoral muscle; sensitivity; specificity; PECTORAL MUSCLE; AUTOMATIC DETECTION; IMAGES;
D O I
10.1080/10798587.2017.1257544
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The proposed method detects the most commonly missed breast cancer symptom, Architectural Distortion. The basis of the method lies in the analysis of geometrical properties of abnormal patterns that correspond to Architectural Distortion in mammograms. Pre-processing methods are employed for the elimination of Pectoral Muscle (PM) region from the mammogram and to localize possible centers of Architectural Distortion. Regions that are candidates to contain centroids of Architectural Distortion are identified using a modification of the isotropic SUSAN filter. Edge features are computed in these regions using Phase Congruency, which are thinned using Gradient Magnitude Maximization. From these thinned edges, relevant edge structures are retained based on three geometric properties namely eccentricity to retain near linear structures, perpendicular distance from each such structure to the centroid of the edges and quadrant support membership of these edge structures. Features for classification are generated from these three properties; a feed-forward neural network, trained using a combination of backpropagation and a metaheuristic algorithm based on Cuckoo search, is employed for classifying the suspicious regions identified by the modified filter for Architectural Distortion, as normal or malignant. Experimental analyses were carried out on mammograms obtained from the standard databases MIAS and DDSM as well as on images obtained from Lakeshore Hospital in Kochi, India. The classification step yielded a sensitivity of 89%, 89.8.7% and 97.6% and specificity of 90.9, 85 and 96.7% on 60 images from MIAS, 100 images from DDSM database and 100 images from Lakeshore Hospital respectively
引用
收藏
页码:183 / 197
页数:15
相关论文
共 50 条
  • [41] Architectural Distortion-Based Digital Mammograms Classification Using Depth Wise Convolutional Neural Network
    Rehman, Khalil ur
    Li, Jianqiang
    Pei, Yan
    Yasin, Anaa
    Ali, Saqib
    Saeed, Yousaf
    BIOLOGY-BASEL, 2022, 11 (01):
  • [42] DETECTION OF ARCHITECTURAL DISTORTION IN MAMMOGRAM IMAGE USING WAVELET TRANSFORM
    Muthukarthigadevi, R.
    Anand, S.
    2013 INTERNATIONAL CONFERENCE ON INFORMATION COMMUNICATION AND EMBEDDED SYSTEMS (ICICES), 2013, : 638 - 643
  • [43] Detection of Architectural Distortion in Mammogram Images using Contourlet Transform
    Anand, S.
    Rathna, R. Aynesh Vijaya
    2013 IEEE INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN COMPUTING, COMMUNICATION AND NANOTECHNOLOGY (ICE-CCN'13), 2013, : 177 - 180
  • [44] Object detection using geometrical block structures
    Cao, Zisheng
    Chen, Feng
    Du, Youtian
    ICNC 2007: THIRD INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, VOL 3, PROCEEDINGS, 2007, : 561 - +
  • [45] An automated method for detecting architectural distortions on mammograms using direction analysis of linear structures
    Matsubara, T.
    Ito, A.
    Tsunomori, A.
    Hara, T.
    Muramatsu, C.
    Endo, T.
    Fujita, H.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 2661 - 2664
  • [46] Characterization of Architectural Distortion in Mammograms Based on Texture Analysis Using Support Vector Machine Classifier with Clinical Evaluation
    Kamra, Amit
    Jain, V. K.
    Singh, Sukhwinder
    Mittal, Sunil
    JOURNAL OF DIGITAL IMAGING, 2016, 29 (01) : 104 - 114
  • [47] Characterization of Architectural Distortion in Mammograms Based on Texture Analysis Using Support Vector Machine Classifier with Clinical Evaluation
    Amit Kamra
    V K Jain
    Sukhwinder Singh
    Sunil Mittal
    Journal of Digital Imaging, 2016, 29 : 104 - 114
  • [48] Human detection using geometrical pixel value structures
    Utsumi, A
    Tetsutani, N
    FIFTH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION, PROCEEDINGS, 2002, : 39 - 44
  • [49] Detection of architectural distortion in prior mammograms using Gabor filters, phase portraits, fractal dimension, and texture analysis [1] (vol 2, pg 347, 2008)
    Banik, Shantanu
    Rangayyan, Rangaraj M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (04) : 421 - 423
  • [50] Detection of Architectural Distortion Using Coherence in Relation to the Expected Orientation of Breast Tissue
    Rangayyan, Rangaraj M.
    Chakraborty, Jayasree
    Banik, Shantanu
    Mukhopadhyay, Sudipta
    Desautels, J. E. Leo
    2012 25TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2012,