Detection of architectural distortion in mammograms using geometrical properties of thinned edge structures

被引:4
|
作者
Lakshmanan, Rekha [1 ]
Shiji, T. P. [1 ]
Jacob, Suma Mariam [2 ]
Pratab, Thara [2 ]
Thomas, Chinchu [3 ]
Thomas, Vinu [1 ]
机构
[1] Govt Model Engn Coll, Dept Elect Engn, Kochi, Kerala, India
[2] Lakeshore Hosp, Kochi, India
[3] Govt Engn Coll, Dept Elect Engn, Cherthala, India
来源
关键词
Architectural distortion; breast cancer; classification; cuckoo search; geometrical properties of edge; structures; mammogram; pectoral muscle; sensitivity; specificity; PECTORAL MUSCLE; AUTOMATIC DETECTION; IMAGES;
D O I
10.1080/10798587.2017.1257544
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The proposed method detects the most commonly missed breast cancer symptom, Architectural Distortion. The basis of the method lies in the analysis of geometrical properties of abnormal patterns that correspond to Architectural Distortion in mammograms. Pre-processing methods are employed for the elimination of Pectoral Muscle (PM) region from the mammogram and to localize possible centers of Architectural Distortion. Regions that are candidates to contain centroids of Architectural Distortion are identified using a modification of the isotropic SUSAN filter. Edge features are computed in these regions using Phase Congruency, which are thinned using Gradient Magnitude Maximization. From these thinned edges, relevant edge structures are retained based on three geometric properties namely eccentricity to retain near linear structures, perpendicular distance from each such structure to the centroid of the edges and quadrant support membership of these edge structures. Features for classification are generated from these three properties; a feed-forward neural network, trained using a combination of backpropagation and a metaheuristic algorithm based on Cuckoo search, is employed for classifying the suspicious regions identified by the modified filter for Architectural Distortion, as normal or malignant. Experimental analyses were carried out on mammograms obtained from the standard databases MIAS and DDSM as well as on images obtained from Lakeshore Hospital in Kochi, India. The classification step yielded a sensitivity of 89%, 89.8.7% and 97.6% and specificity of 90.9, 85 and 96.7% on 60 images from MIAS, 100 images from DDSM database and 100 images from Lakeshore Hospital respectively
引用
收藏
页码:183 / 197
页数:15
相关论文
共 50 条
  • [21] Measures of divergence of oriented patterns for the detection of architectural distortion in prior mammograms
    Rangayyan, Rangaraj M.
    Banik, Shantanu
    Chakraborty, Jayasree
    Mukhopadhyay, Sudipta
    Desautels, J. E. Leo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (04) : 527 - 545
  • [22] Measures of angular spread and entropy for the detection of architectural distortion in prior mammograms
    Banik, Shantanu
    Rangayyan, Rangaraj M.
    Desautels, J. E. Leo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (01) : 121 - 134
  • [23] Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
    Rangayyan, Rangaraj M.
    Banik, Shantanu
    Desautels, J. E. Leo
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (78):
  • [24] A pilot study of architectural distortion detection in mammograms based on characteristics of line shadows
    Nemoto, Mitsutaka
    Honmura, Soshi
    Shimizu, Akinobu
    Furukawa, Daisuke
    Kobatake, Hidefumi
    Nawano, Shigeru
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (01) : 27 - 36
  • [25] Computer-aided detection of architectural distortion in prior mammograms of interval cancer
    Banik, Shantanu
    Rangayyan, Rangaraj M.
    Leo Desautels, J.E.
    Synthesis Lectures on Biomedical Engineering, 2013, 47 : 1 - 193
  • [26] Computer-Aided Detection of Architectural Distortion in Prior Mammograms of Interval Cancer
    Rangaraj M. Rangayyan
    Shantanu Banik
    J. E. Leo Desautels
    Journal of Digital Imaging, 2010, 23 : 611 - 631
  • [27] Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model
    Fábio J. Ayres
    Rangaraj M. Rangayyan
    International Journal of Computer Assisted Radiology and Surgery, 2007, 1 : 361 - 369
  • [28] A computer-aided detection of the architectural distortion in digital mammograms using the fractal dimension measurements of BEMD
    Zyout, Imad
    Togneri, Roberto
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2018, 70 : 173 - 184
  • [29] Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model
    Ayres, Fabio J.
    Rangayyan, Rangaraj M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 1 (06) : 361 - 369
  • [30] Computer-Aided Detection of Architectural Distortion in Prior Mammograms of Interval Cancer
    Rangayyan, Rangaraj M.
    Banik, Shantanu
    Desautels, J. E. Leo
    JOURNAL OF DIGITAL IMAGING, 2010, 23 (05) : 611 - 631