Detection of architectural distortion in mammograms using geometrical properties of thinned edge structures

被引:4
|
作者
Lakshmanan, Rekha [1 ]
Shiji, T. P. [1 ]
Jacob, Suma Mariam [2 ]
Pratab, Thara [2 ]
Thomas, Chinchu [3 ]
Thomas, Vinu [1 ]
机构
[1] Govt Model Engn Coll, Dept Elect Engn, Kochi, Kerala, India
[2] Lakeshore Hosp, Kochi, India
[3] Govt Engn Coll, Dept Elect Engn, Cherthala, India
来源
关键词
Architectural distortion; breast cancer; classification; cuckoo search; geometrical properties of edge; structures; mammogram; pectoral muscle; sensitivity; specificity; PECTORAL MUSCLE; AUTOMATIC DETECTION; IMAGES;
D O I
10.1080/10798587.2017.1257544
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The proposed method detects the most commonly missed breast cancer symptom, Architectural Distortion. The basis of the method lies in the analysis of geometrical properties of abnormal patterns that correspond to Architectural Distortion in mammograms. Pre-processing methods are employed for the elimination of Pectoral Muscle (PM) region from the mammogram and to localize possible centers of Architectural Distortion. Regions that are candidates to contain centroids of Architectural Distortion are identified using a modification of the isotropic SUSAN filter. Edge features are computed in these regions using Phase Congruency, which are thinned using Gradient Magnitude Maximization. From these thinned edges, relevant edge structures are retained based on three geometric properties namely eccentricity to retain near linear structures, perpendicular distance from each such structure to the centroid of the edges and quadrant support membership of these edge structures. Features for classification are generated from these three properties; a feed-forward neural network, trained using a combination of backpropagation and a metaheuristic algorithm based on Cuckoo search, is employed for classifying the suspicious regions identified by the modified filter for Architectural Distortion, as normal or malignant. Experimental analyses were carried out on mammograms obtained from the standard databases MIAS and DDSM as well as on images obtained from Lakeshore Hospital in Kochi, India. The classification step yielded a sensitivity of 89%, 89.8.7% and 97.6% and specificity of 90.9, 85 and 96.7% on 60 images from MIAS, 100 images from DDSM database and 100 images from Lakeshore Hospital respectively
引用
收藏
页码:183 / 197
页数:15
相关论文
共 50 条
  • [1] Detection of architectural distortion in mammograms using phase portraits
    Ayres, FJ
    Rangayyan, RM
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 587 - 597
  • [2] Detection of architectural distortion in mammograms using fractal analysis
    Tourassi, GD
    Eltonsy, NH
    Elmaghraby, AS
    Floyd, CE
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 930 - 938
  • [3] Detection of Architectural Distortion in Prior Mammograms
    Banik, Shantanu
    Rangayyan, Rangaraj M.
    Desautels, J. E. Leo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 279 - 294
  • [4] The detection of architectural distortion in mammograms by using support vector machine
    Gong, Zhu-Lin
    Chen, Ying
    Zhang, Lu
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2009, 43 (07): : 1038 - 1042
  • [5] Detection of Architectural Distortion in Prior Mammograms Using Measures of Angular Distribution
    Rangayyan, Rangaraj M.
    Banik, Shantanu
    Desautels, J. E. Leo
    MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963
  • [6] Architectural Distortion Detection from Mammograms Using Support Vector Machine
    Netprasat, Orawan
    Auephanwiriyakul, Sansanee
    Theera-Umpon, Nipon
    PROCEEDINGS OF THE 2014 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2014, : 3258 - 3264
  • [7] Automated detection scheme of architectural distortion in mammograms using adaptive Gabor filter
    Yoshikawa, Ruriha
    Teramoto, Atsushi
    Matsubara, Tomoko
    Fujita, Hiroshi
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [8] Detection of Architectural Distortion in Prior Mammograms Using Statistical Measures of Orientation of Texture
    Chakraborty, Jayasree
    Rangayyan, Rangaraj M.
    Banik, Shantanu
    Mukhopadhyay, Sudipta
    Desautels, J. E. Leo
    MEDICAL IMAGING 2012: COMPUTER-AIDED DIAGNOSIS, 2012, 8315
  • [9] Estimation of Architectural Distortion in Mammograms using Fractal Features
    Bhowmik, Mrinal Kanti
    Roy, Anindita, Jr.
    Gogoi, Usha Rani
    Nath, Niharika
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [10] Analysis of oriented texture: With applications to the detection of architectural distortion in mammograms
    Ayres F.J.
    Rangayyan R.M.
    Desautels J.E.L.
    Synthesis Lectures on Biomedical Engineering, 2010, 38 : 1 - 162