A 3-dimensional rigid cluster thorax model for kinematic measurements during gait

被引:18
|
作者
Kiernan, D. [1 ,2 ]
Malone, A. [1 ]
O'Brien, T. [1 ]
Simms, C. K. [2 ]
机构
[1] Cent Remedial Clin, Gait Lab, Dublin 3, Ireland
[2] Univ Dublin Trinity Coll, Trinity Ctr Bioengn, Dublin 2, Ireland
关键词
Thorax; 3-Dimensional; Rigid cluster; Validation; Gait; TRUNK KINEMATICS; LOW-BACK; MYELOMENINGOCELE; COORDINATION; MOVEMENTS; CHILDREN; PLANE; HIP;
D O I
10.1016/j.jbiomech.2014.02.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The trunk has been shown to work as an active segment rather than a passenger unit during gait and it is felt that trunk kinematics should be given more consideration during gait assessment. While 3-dimensional assessment of the thorax with respect to the pelvis and laboratory can provide a comprehensive description of trunk movement, the majority of existing 3-D thorax models demonstrate shortcomings such as the need for multiple skin marker configurations, difficult landmark identification and practical issues for assessment on female subjects. A small number of studies have used rigid cluster models to quantify thorax movement, however the models and points of attachment are not well described and validation rarely considered. The aim of this study was to propose an alternative rigid cluster 3-D thorax model to quantify movement during gait and provide validation of this model. A rigid mount utilising active markers was developed and applied over the 3rd thoracic vertebra, previously reported as an area of least skin movement artefact on the trunk. The model was compared to two reference thorax models through simultaneous recording during gait on 15 healthy subjects. Excellent waveform similarity was demonstrated between the proposed model and the two reference models (CMC range 0.962-0.997). Agreement of discrete parameters was very-good to excellent. In addition, ensemble average graphs demonstrated almost identical curve displacement between models. The results suggest that the proposed model can be confidently used as an alternative to other thorax models in the clinical setting. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1499 / 1505
页数:7
相关论文
共 50 条
  • [41] 3-DIMENSIONAL T-J MODEL AND CLUSTER VARIATION METHOD
    TANAKA, K
    TAKANE, Y
    EBISAWA, H
    MORITA, T
    PHYSICA B, 1994, 194 : 481 - 482
  • [42] TEST OF SINGLE CLUSTER UPDATE FOR THE 3-DIMENSIONAL XY-MODEL
    JANKE, W
    PHYSICS LETTERS A, 1990, 148 (6-7) : 306 - 312
  • [43] The repeatability of 3-dimensional scapular kinematic analysis during bilateral upper extremity movements
    Yildiz, Taha Ibrahim
    Eraslan, Leyla
    Demirci, Serdar
    Kara, Dilara
    Ulusoy, Burak
    Turgut, Elif
    Duzgun, Irem
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2020, 24 (04) : 37 - 42
  • [44] KINEMATIC ANALYSIS OF 3-DIMENSIONAL MOTION IN LOADING OPERATIONS
    IWATA, K
    MORIWAKI, T
    KAWANO, T
    ERGONOMICS, 1982, 25 (06) : 495 - 495
  • [45] 3-DIMENSIONAL KINETIC AND KINEMATIC TESTING IN KNEE DISORDERS
    WHITTLE, MW
    DESHMUKH, BA
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (03): : 385 - 385
  • [46] 3-DIMENSIONAL KINEMATIC MIGRATION IN VARIABLE VELOCITY MEDIA
    WEN, J
    MCMECHAN, GA
    GEOPHYSICAL PROSPECTING, 1987, 35 (03) : 250 - 266
  • [47] EFFECTS OF RIGID FIXATION DEVICE COMPOSITION ON 3-DIMENSIONAL COMPUTED AXIAL-TOMOGRAPHY IMAGING - DIRECT MEASUREMENTS ON A PIG MODEL
    BARONE, CM
    EISIG, S
    WALLACH, S
    MEDNICK, R
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 52 (07) : 737 - 740
  • [48] Respiratory gating for 3-dimensional PET of the thorax:: Feasibility and initial results
    Boucher, L
    Rodrigue, S
    Lecomte, R
    Bénard, F
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (02) : 214 - 219
  • [49] ERROR ANALYSIS IN 3-DIMENSIONAL MEASUREMENTS
    NAWARA, L
    KOWALSKI, M
    MECHANIK MIESIECZNIK NAUKOWO-TECHNICZNY, 1980, 53 (12): : 674 - 679
  • [50] A POSITION DIGITIZER FOR 3-DIMENSIONAL MEASUREMENTS
    BLAND, WL
    TRANSACTIONS OF THE ASAE, 1989, 32 (01): : 189 - 192