Respiratory gating for 3-dimensional PET of the thorax:: Feasibility and initial results

被引:0
|
作者
Boucher, L [1 ]
Rodrigue, S [1 ]
Lecomte, R [1 ]
Bénard, F [1 ]
机构
[1] CHUS, Hop Fleurimont, Clin Res Ctr, Metab & Funct Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
关键词
motion correction; respiratory gating; F-18-FDG; PET;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion may reduce the sensitivity of F-18-FDG PET for the detection of small pulmonary nodules close to the base of the lungs. This motion also interferes with attempts to use fused PET/CT images through software or combined PET/CT devices. This study was undertaken to assess the feasibility of respiratory gating for PET of the chest and the impact of respiratory motion on quantitative analysis. Methods: Ten healthy subjects were enrolled in this study. Three-dimensional studies were acquired with 8 gates per respiratory cycle on a commercial PET scanner with a temperature-sensitive respiratory gating device built in-house. All scans were obtained over 42 cm of body length with 3 bed positions of 10 min each after injection of F-18-FDG at 4.5 MBq/kg. The reconstructed images were assembled to produce gated whole-body volumes and maximum-intensity projections. The amplitude of respiratory motion of the kidneys (as a surrogate for diaphragmatic incursion) as well as the apex of the heart was measured in the coronal plane. Phantom studies were acquired to simulate the impact of respiratory motion on quantitative uptake measurements. Results: The respiratory gating device produced a consistent, reliable trigger signal. All acquisitions were successful and produced reconstructed volumes with excellent image quality. Mean+/-SD motion amplitude and maximal motion amplitude values were 6.7+/-3.0 and 11.9 mm for the heart, 12.0+/-3.7 and 18.8 mm for the right kidney, and 11.1+/-4.8 and 17.1 mm for the left kidney, respectively. In phantom studies, the standardized uptake value for a 1-mL lesion was underestimated by 30% and 48% for the average and maximal respiratory motion values, respectively. Conclusion: Respiratory gating of PET of the thorax and upper abdomen is a practical and feasible approach that may improve the detection of small pulmonary nodules. Further work is planned to assess prospectively the diagnostic accuracy of this new method.
引用
收藏
页码:214 / 219
页数:6
相关论文
共 50 条
  • [1] Respiratory gated 3D PET of the thorax: Feasibility and initial results.
    Boucher, L
    Rodrigue, S
    Lecomte, R
    Benard, F
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 41P - 42P
  • [2] Respiratory gating in FDG PET/CT: An initial experience
    Hosseini, Sana
    Tran, Isaac
    Botkin, Crystal
    Mohiuddin, Asif
    Nghi Nguyen
    Osman, Medhat
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [3] Feasibility of image derived respiratory gating of FDG PET datasets
    Visvikis, D
    Barret, O
    Turzo, A
    Fryer, TD
    Bizais, Y
    Carson, K
    Jarritt, P
    Cheze-Le Rest, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S230 - S230
  • [4] REAL-TIME, 3-DIMENSIONAL ECHOCARDIOGRAPHY - FEASIBILITY AND INITIAL USE
    SHEIKH, KH
    SMITH, SW
    VONRAMM, O
    KISSLO, J
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1991, 8 (01): : 119 - 125
  • [5] Transthoracic Impedance Based Respiratory Gating in PET Imaging: a Feasibility Study
    Ahmed, Mohamed A. A.
    Xiao, Peng
    Xie, Qingguo
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [6] Feasibility of a new 3-dimensional scanning probe for the rectum: Preliminary results
    Ishihara, Y
    Abe, T
    Otake, Y
    Ishitsuka, S
    Sakai, Y
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S138 - S138
  • [7] 3-DIMENSIONAL FINITE-ELEMENT MODEL OF HUMAN THORAX
    AHMED, M
    BARKER, RL
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 79 - 79
  • [8] Correction for the coincidence detections due to Compton scattering on 3-dimensional acquisition PET for the quantitative thorax measurement.
    Narita, Y
    Shidahara, M
    Nakamura, T
    Fujiwara, T
    Watanuki, S
    Miyake, M
    Itoh, M
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 98P - 98P
  • [9] Image-navigated 3-dimensional late gadolinium enhancement cardiovascular magnetic resonance imaging: feasibility and initial clinical results
    Bratis, Konstantinos
    Henningsson, Markus
    Grigoratos, Chrysanthos
    Dell'Omodarme, Matteo
    Chasapides, Konstantinos
    Botnar, Rene
    Nagel, Eike
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [10] ‘Image-navigated 3-dimensional late gadolinium enhancement cardiovascular magnetic resonance imaging: feasibility and initial clinical results’
    Konstantinos Bratis
    Markus Henningsson
    Chrysanthos Grigoratos
    Matteo Dell’Omodarme
    Konstantinos Chasapides
    Rene Botnar
    Eike Nagel
    Journal of Cardiovascular Magnetic Resonance, 19