Atraumatic Delayed Orbital Hematoma Sixteen Years After Orbital Floor Fracture Repair With Porous Polyethylene Implant

被引:7
|
作者
Slentz, Dane Harper [1 ]
Rajjoub, Lamise [2 ]
Domanski, Mark [3 ]
机构
[1] Univ Michigan, WK Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[2] George Washington Univ, Sch Med & Hlth Sci, Dept Ophthalmol, Washington, DC 20052 USA
[3] Inova Fairfax Hosp, Div Plast Surg, Fairfax, VA USA
关键词
Atraumatic delayed orbital hematoma; orbital floor fracture; porous polyethylene implant;
D O I
10.1097/SCS.0000000000005139
中图分类号
R61 [外科手术学];
学科分类号
摘要
Porous alloplastic materials such as titanium mesh and porous polyethylene allow for the ingrowth of fibrovascular tissues into the implant; stabilizing the implant and reducing the risk of extrusion and extrusion-related complications (such as hematoma formation). The literature contains 2 specific reports of delayed atraumatic orbital hematomas occurring 8 months and 3 years after orbital floor reconstruction with porous polyethylene implants. In this study, an atraumatic orbital hematoma occurring 16 years after orbital floor reconstruction with a porous polyethylene implant was presented. The hematoma was evacuated and the implant was removed without replacement of a secondary implant. The remaining fibrovascular tissue on the underside of the implant provided enough support of the orbital soft tissues to achieve excellent anatomic and physiologic outcomes.
引用
收藏
页码:539 / 540
页数:2
相关论文
共 50 条
  • [41] Porous polyethylene implants in orbital floor reconstruction
    Lin, I-Chan
    Liao, Shu-Lang
    Lin, Luke L. K.
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2007, 106 (01) : 51 - 57
  • [42] Porous polyethylene implants in orbital floor reconstruction
    Lin, IC
    Liao, SL
    Lin, LLK
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2006, 50 (02) : 187 - 188
  • [43] Reply Re: warfarin-associated delayed orbital haemorrhage after orbital fracture repair with smooth nylon foil implant
    Jaru-Ampornpan, Pimkwan
    Joseph, Shannon S.
    Grisolia, Ana Beatriz
    Briceno, Cesar
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2019, 38 (06): : 525 - 525
  • [44] Orbital Emphysema After Repair of Orbital Fracture
    Wang, Hang
    An, Jingang
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (07) : E687 - E688
  • [45] Feasibility Study for Transnasal Endoscopic Repair of Orbital Floor Fracture With Alloplastic Implant
    Engle, Robert D.
    Chaskes, Mark
    Wladis, Edward
    Pinheiro-Neto, Carlos D.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2016, 125 (12): : 970 - 975
  • [46] Actinomyces infection in porous polyethylene orbital implant
    Zeynel A. Karcioglu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 1997, 235 : 448 - 451
  • [47] Actinomyces infection in porous polyethylene orbital implant
    Karcioglu, ZA
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1997, 235 (07) : 448 - 451
  • [48] Porous polyethylene orbital implant in patients with retinoblastoma
    Karcioglu, ZA
    Al-Mesfer, SA
    Mullaney, PB
    OPHTHALMOLOGY, 1998, 105 (07) : 1311 - 1316
  • [49] Eyelashes on an extruding porous polyethylene orbital implant
    Robberecht K.
    Berghmans L.
    Kestelyn P.
    Decock C.
    International Ophthalmology, 2011, 31 (1) : 21 - 22
  • [50] Infection of a porous polyethylene orbital implant with Capnocytophaga
    Wilson, MW
    Wobig, JL
    Dailey, RA
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 14 (06): : 398 - 402