Atraumatic Delayed Orbital Hematoma Sixteen Years After Orbital Floor Fracture Repair With Porous Polyethylene Implant

被引:7
|
作者
Slentz, Dane Harper [1 ]
Rajjoub, Lamise [2 ]
Domanski, Mark [3 ]
机构
[1] Univ Michigan, WK Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[2] George Washington Univ, Sch Med & Hlth Sci, Dept Ophthalmol, Washington, DC 20052 USA
[3] Inova Fairfax Hosp, Div Plast Surg, Fairfax, VA USA
关键词
Atraumatic delayed orbital hematoma; orbital floor fracture; porous polyethylene implant;
D O I
10.1097/SCS.0000000000005139
中图分类号
R61 [外科手术学];
学科分类号
摘要
Porous alloplastic materials such as titanium mesh and porous polyethylene allow for the ingrowth of fibrovascular tissues into the implant; stabilizing the implant and reducing the risk of extrusion and extrusion-related complications (such as hematoma formation). The literature contains 2 specific reports of delayed atraumatic orbital hematomas occurring 8 months and 3 years after orbital floor reconstruction with porous polyethylene implants. In this study, an atraumatic orbital hematoma occurring 16 years after orbital floor reconstruction with a porous polyethylene implant was presented. The hematoma was evacuated and the implant was removed without replacement of a secondary implant. The remaining fibrovascular tissue on the underside of the implant provided enough support of the orbital soft tissues to achieve excellent anatomic and physiologic outcomes.
引用
收藏
页码:539 / 540
页数:2
相关论文
共 50 条
  • [31] An infected porous polyethylene orbital implant
    Jordan, David R.
    Brownstein, Seymour
    Rawlings, Nigel
    Robinson, Jennifer
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 23 (05): : 413 - 415
  • [32] Re: warfarin-associated delayed orbital haemorrhage after orbital fracture repair with smooth nylon foil implant
    McNab, Alan A.
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2019, 38 (06): : 524 - 524
  • [33] Orbital floor fracture repair - Reply
    Hamilton, Jason S.
    ARCHIVES OF FACIAL PLASTIC SURGERY, 2007, 9 (04) : 301 - 301
  • [34] ASPECTS OF ORBITAL FLOOR FRACTURE REPAIR
    DUGUID, IM
    WILSON, JSP
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1982, 102 (APR): : 106 - 108
  • [35] Incidence of Orbital Mucocele following Orbital Floor Fracture Repair
    Nachabe, Adeem M.
    Messa, Genevieve E.
    Boraski, Jonathan C.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2024, 12 (06)
  • [36] VARIABLE DIPLOPIA AND BLEPHAROPTOSIS AFTER ORBITAL FLOOR FRACTURE REPAIR
    VAUGHN, GL
    HASS, AN
    BOSLEY, TM
    FLANAGAN, JC
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 117 (03) : 407 - 409
  • [37] The Role of Postoperative Imaging after Orbital Floor Fracture Repair
    Carpenter, David
    Shammas, Ronnie
    Honeybrook, Adam
    Brown, C. Scott
    Chapurin, Nikita
    Woodard, Charles R.
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2018, 11 (02) : 96 - 101
  • [38] Persistent Upgaze Restriction after Orbital Floor Fracture Repair
    DeParis, Sarah Willcox
    Grumbine, F. Lawson
    Vagefi, M. Reza
    Kersten, Robert C.
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2016, 9 (03) : 268 - 270
  • [39] Porous Polyethylene Implants in Orbital Floor Reconstruction
    I-Chan Lin
    Shu-Lang Liao
    Luke L-K Lin
    Japanese Journal of Ophthalmology, 2006, 50 : 187 - 188
  • [40] Porous polyethylene implants in orbital floor reconstruction
    Villarreal, PM
    Monje, F
    Morillo, AJ
    Junquera, LM
    González, C
    Barbón, JJ
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 109 (03) : 877 - 885