Atraumatic Delayed Orbital Hematoma Sixteen Years After Orbital Floor Fracture Repair With Porous Polyethylene Implant

被引:7
|
作者
Slentz, Dane Harper [1 ]
Rajjoub, Lamise [2 ]
Domanski, Mark [3 ]
机构
[1] Univ Michigan, WK Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[2] George Washington Univ, Sch Med & Hlth Sci, Dept Ophthalmol, Washington, DC 20052 USA
[3] Inova Fairfax Hosp, Div Plast Surg, Fairfax, VA USA
关键词
Atraumatic delayed orbital hematoma; orbital floor fracture; porous polyethylene implant;
D O I
10.1097/SCS.0000000000005139
中图分类号
R61 [外科手术学];
学科分类号
摘要
Porous alloplastic materials such as titanium mesh and porous polyethylene allow for the ingrowth of fibrovascular tissues into the implant; stabilizing the implant and reducing the risk of extrusion and extrusion-related complications (such as hematoma formation). The literature contains 2 specific reports of delayed atraumatic orbital hematomas occurring 8 months and 3 years after orbital floor reconstruction with porous polyethylene implants. In this study, an atraumatic orbital hematoma occurring 16 years after orbital floor reconstruction with a porous polyethylene implant was presented. The hematoma was evacuated and the implant was removed without replacement of a secondary implant. The remaining fibrovascular tissue on the underside of the implant provided enough support of the orbital soft tissues to achieve excellent anatomic and physiologic outcomes.
引用
收藏
页码:539 / 540
页数:2
相关论文
共 50 条
  • [1] Delayed-Onset Orbital Abscess After Orbital Blowout Fracture Repair Using Porous Polyethylene Implant
    Han, Kwang Eon
    Ahn, Jung Hyo
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (06) : e588 - e590
  • [2] Delayed Repair of Lateral Orbital Wall and Orbital Floor Fracture
    Lee, James
    Tahiri, Youssef
    Roy, Andree-Anne
    Lessard, Lucie
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (01) : 34 - 37
  • [3] Porous Polyethylene Implant Associated With Delayed Orbital Complications and Osteomyelitis After Orbital Reconstruction
    Suh, Su Youn
    Yeom, Jeong A.
    Ahn, Jung Hyo
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (07) : 1910 - 1911
  • [4] Delayed Periorbital Abscess after Silicone Implant to Orbital Floor Fracture
    Dedhia, Raj
    Tollefson, Travis T.
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2016, 9 (02) : 185 - 187
  • [5] Chronic Subperiosteal Hematic Cyst Formation Twelve Years After Orbital Fracture Repair with Alloplastic Orbital Floor Implant
    Glavas, Ioannis P.
    Lissauer, Boaz J.
    Hornblass, Albert
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2005, 24 (01): : 47 - 49
  • [6] Nursing care for the application of a porous polyethylene orbital implant in the repair of orbital fracture and subsequent postoperative treatment
    Cheng, Fang-Fang
    Deng, Hong-Wei
    Fan, Xian-Ming
    Xiong, Mei
    ASIAN JOURNAL OF SURGERY, 2023, 46 (08) : 3341 - 3342
  • [7] Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports
    Aryasit, Orapan
    Ng, Danny S.
    Goh, Alice S. C.
    Woo, Kyung In
    Kim, Yoon-Duck
    BMC OPHTHALMOLOGY, 2016, 16
  • [8] Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports
    Orapan Aryasit
    Danny S. Ng
    Alice S. C. Goh
    Kyung In Woo
    Yoon-Duck Kim
    BMC Ophthalmology, 16
  • [9] Repair of fractures of the orbital floor with porous polyethylene implants
    Yilmaz, Mustafa
    Vayvada, Haluk
    Aydin, Enver
    Menderes, Adnan
    Atabey, Atay
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2007, 45 (08): : 640 - 644
  • [10] A Case of Delayed Orbital Cellulitis after Orbital Wall Fracture Repair Using Absorbable Implant
    Kim, Jinsoo
    Lee, Min Joung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (07): : 1165 - 1169