A high-precision X-ray beam-position and profile monitor for synchrotron beamlines

被引:14
|
作者
van Silfhout, RG [1 ]
机构
[1] DESY, EMBL, D-22603 Hamburg, Germany
关键词
X-ray beam-position monitors;
D O I
10.1107/S0909049599010596
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel monitor for X-ray beam position, intensity and profile is presented. This diagnostic instrument is based on a commercial photodiode array which detects X-rays scattered diffusely from a featureless foil. The typical accuracy with which the beam position is determined is 1 mu m. Although initially conceived for the characterization of 'white' synchrotron radiation, this monitor has proven to be suitable for monochromatic radiation as well. hence providing a single solution to the task of beam characterization along the X-ray beam path, from source to sample.
引用
收藏
页码:1071 / 1075
页数:5
相关论文
共 50 条
  • [41] Diamond-based semi-transparent beam-position monitor for synchrotron radiation applications
    Bergonzo, P.
    Brambilla, A.
    Tromson, D.
    Marshall, R.D.
    Jany, C.
    Foulon, F.
    Gauthier, C.
    Sole, V.A.
    Rogalev, A.
    Goulon, J.
    Journal of Synchrotron Radiation, 1999, 6 (01): : 1 - 5
  • [42] X-ray beam-position monitoring in the sub-micrometre and sub-second regime
    Bunk, O
    Pfeiffer, F
    Stampanoni, M
    Patterson, BD
    Schulze-Briese, C
    David, C
    JOURNAL OF SYNCHROTRON RADIATION, 2005, 12 : 795 - 799
  • [43] Silicon carbide X-ray beam position monitors for synchrotron applications
    Nida, Selamnesh
    Tsibizov, Alexander
    Ziemann, Thomas
    Woerle, Judith
    Moesch, Andy
    Schulze-Briese, Clemens
    Pradervand, Claude
    Tudisco, Salvatore
    Sigg, Hans
    Bunk, Oliver
    Grossner, Ulrike
    Camarda, Massimo
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 (01): : 28 - 35
  • [44] An X-ray beam position monitor based on the photoluminescence of helium gas
    Revesz, P
    White, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 540 (2-3): : 470 - 479
  • [45] High-precision parallel-beam X-ray system for high-temperature diffraction studies
    Mitsunaga, T
    Saigo, M
    Fujinawa, G
    POWDER DIFFRACTION, 2002, 17 (03) : 173 - 177
  • [46] The Broadband and High Sensitivity X-Ray Beam Position Monitor of the IR beamline MIRIAM at Diamond
    Cinque, Gianfelice
    Howell, George
    Cobb, Tom
    Tartoni, Nicola
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [47] Transmissive imaging X-ray Beam Position Monitors (XBPM) for Protein Crystallography (PX) beamlines
    Fuchs, Martin R.
    Holldack, Karsten
    Reichardt, Gerd
    Mueller, Uwe
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1006 - +
  • [48] High-precision measurement of the x-ray Cu Kα spectrum
    Mendenhall, Marcus H.
    Henins, Albert
    Hudson, Lawrence T.
    Szabo, Csilla I.
    Windover, Donald
    Cline, James P.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2017, 50 (11)
  • [49] High-precision X-ray diffractometer on the base of acoustic monochromator
    A. R. Mkrtchyan
    A. H. Mkrtchyan
    V. R. Kocharyan
    A. E. Movsisyan
    S. B. Dabagov
    A. P. Potylicyn
    Journal of Contemporary Physics (Armenian Academy of Sciences), 2013, 48 : 141 - 143
  • [50] High-precision X-ray diffractometer on the base of acoustic monochromator
    Mkrtchyan, A. R.
    Mkrtchyan, A. H.
    Kocharyan, V. R.
    Movsisyan, A. E.
    Dabagov, S. B.
    Potylicyn, A. P.