共 42 条
Use of Partial Discharge Inception Voltage Measurements to Design a Gaseous Helium Cooled High Temperature Superconducting Power Cable
被引:20
|作者:
Cheetham, Peter
[1
]
Kim, WooJin
[1
]
Kim, Chul Han
[1
]
Pamidi, Sastry V.
[1
]
Graber, Lukas
[2
]
Rodrigo, Horatio
[3
]
机构:
[1] Florida State Univ, Ctr Adv Power Syst, Tallahassee, FL 32310 USA
[2] Georgia Inst Technol, Atlanta, GA 30332 USA
[3] Dielect Sci Inc, Chelmsford, MA 01824 USA
关键词:
Cryogenics;
partial discharge;
superconducting power cable;
ELECTRICAL INSULATION;
TRANSMISSION;
CRYOSTAT;
SYSTEM;
LINES;
D O I:
10.1109/TDEI.2016.005909
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
The occurrence of partial discharge is one of the challenges that limit the design options and voltage ratings of gaseous helium cooled high temperature superconducting (HTS) cables. The measurements of partial discharge inception voltage (PDIV) at cryogenic temperatures on several model cables were used in the optimization of the dielectric design of a 30 m long HTS power cable, which was successfully fabricated and tested at DC currents up to 6 kA and voltage of 3.5 kV RMS. Details of the PDIV measurements are described.
引用
收藏
页码:191 / 199
页数:9