Use of Partial Discharge Inception Voltage Measurements to Design a Gaseous Helium Cooled High Temperature Superconducting Power Cable

被引:20
|
作者
Cheetham, Peter [1 ]
Kim, WooJin [1 ]
Kim, Chul Han [1 ]
Pamidi, Sastry V. [1 ]
Graber, Lukas [2 ]
Rodrigo, Horatio [3 ]
机构
[1] Florida State Univ, Ctr Adv Power Syst, Tallahassee, FL 32310 USA
[2] Georgia Inst Technol, Atlanta, GA 30332 USA
[3] Dielect Sci Inc, Chelmsford, MA 01824 USA
关键词
Cryogenics; partial discharge; superconducting power cable; ELECTRICAL INSULATION; TRANSMISSION; CRYOSTAT; SYSTEM; LINES;
D O I
10.1109/TDEI.2016.005909
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The occurrence of partial discharge is one of the challenges that limit the design options and voltage ratings of gaseous helium cooled high temperature superconducting (HTS) cables. The measurements of partial discharge inception voltage (PDIV) at cryogenic temperatures on several model cables were used in the optimization of the dielectric design of a 30 m long HTS power cable, which was successfully fabricated and tested at DC currents up to 6 kA and voltage of 3.5 kV RMS. Details of the PDIV measurements are described.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 42 条
  • [41] Design of non-flammable mixed refrigerant Joule-Thomson refrigerator for precooling stage of high temperature superconducting power cable
    Lee, Cheonkyu
    Jin, Lingxue
    Park, Changgi
    Jeong, Sangkwon
    CRYOGENICS, 2017, 81 : 14 - 23
  • [42] Insulation Design and Simulation for Three-Phase Concentric High-Temperature Superconducting Cable Under 10-kV Power System
    Pi, Wei
    Yang, Quan
    Wang, Tengyan
    Peng, Chang
    Wang, Yinshun
    Shi, Qingmei
    Dong, Jin
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)