Use of Partial Discharge Inception Voltage Measurements to Design a Gaseous Helium Cooled High Temperature Superconducting Power Cable

被引:20
|
作者
Cheetham, Peter [1 ]
Kim, WooJin [1 ]
Kim, Chul Han [1 ]
Pamidi, Sastry V. [1 ]
Graber, Lukas [2 ]
Rodrigo, Horatio [3 ]
机构
[1] Florida State Univ, Ctr Adv Power Syst, Tallahassee, FL 32310 USA
[2] Georgia Inst Technol, Atlanta, GA 30332 USA
[3] Dielect Sci Inc, Chelmsford, MA 01824 USA
关键词
Cryogenics; partial discharge; superconducting power cable; ELECTRICAL INSULATION; TRANSMISSION; CRYOSTAT; SYSTEM; LINES;
D O I
10.1109/TDEI.2016.005909
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The occurrence of partial discharge is one of the challenges that limit the design options and voltage ratings of gaseous helium cooled high temperature superconducting (HTS) cables. The measurements of partial discharge inception voltage (PDIV) at cryogenic temperatures on several model cables were used in the optimization of the dielectric design of a 30 m long HTS power cable, which was successfully fabricated and tested at DC currents up to 6 kA and voltage of 3.5 kV RMS. Details of the PDIV measurements are described.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 42 条
  • [31] CONTROLLING DELETERIOUS EFFECTS OF PARTIAL DISCHARGE ON HIGH-VOLTAGE CABLE COUPLERS IN MINE POWER-SYSTEMS
    BISE, CJ
    KADYK, RC
    MINING ENGINEERING, 1984, 36 (03) : 265 - 270
  • [32] Partial discharge inception characteristics of LN2/polypropylene laminated paper composite insulation system for high temperature superconducting cables
    Hayakawa, N
    Kobayashi, T
    Hazeyama, M
    Takahashi, T
    Yasuda, K
    Okubo, H
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (01) : 166 - 174
  • [33] STUDIES FOR OPTIMUM DESIGN OF THERMODYNAMIC CYCLES OF HELIUM-COOLED HIGH-TEMPERATURE NUCLEAR POWER STATIONS
    WLEZEK, C
    ATOMKERNENERGIE, 1970, 16 (04): : 311 - &
  • [34] Electric field investigation in high voltage power modules using finite element simulations and partial discharge measurements
    Frey, D
    Schanen, JL
    Augé, JL
    Lesaint, O
    2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS, 2003, : 1000 - 1005
  • [35] Underground Power Cable On Site Testing Experience Using Resonant High Voltage Power Supplies and Partial Discharge Ultra Wide Band Methods
    Escorsa M, Oscar
    Garcia-Colon, V. R.
    2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 856 - 860
  • [36] Design and Implementation of Ultra-Wide Band Antenna for Partial Discharge Detection in High Voltage Power Equipment
    Uwiringiyimana, Jean Pierre
    Khayam, Umar
    Suwarno
    Montanari, Gian Carlo
    IEEE ACCESS, 2022, 10 : 10983 - 10994
  • [37] On-line partial discharge monitoring system and data processing using WTST-NST filter for high voltage power cable
    Wang, Hui
    Huang, Chengjun
    Zhang, Li
    Qian, Yong
    Liu, Junhua
    Yao, Linpeng
    Guo, Canxin
    Jiang, Xiuchen
    WSEAS Transactions on Circuits and Systems, 2009, 8 (07): : 609 - 619
  • [38] Gray intensity image feature extraction of partial discharge in high-voltage cross-linked polyethylene power cable joint
    Wei, Gang
    Tang, Ju
    Zhang, Xiaoxing
    Lin, Junyi
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2014, 24 (02): : 215 - 226
  • [39] DESIGN OF A RACE-TRACK COIL FOR MEASUREMENTS OF AC POWER LOSSES IN HIGH-TEMPERATURE SUPERCONDUCTING TAPES
    Trojanowski, Stanislaw
    Ciszek, Marian
    Maievskyi, Eduard
    METROLOGY AND MEASUREMENT SYSTEMS, 2014, 21 (02) : 293 - 304
  • [40] Design of oil-free simple turbo type 65K/6KW helium and neon mixture gas refrigerator for high temperature superconducting power cable cooling
    Saji, N
    Asakura, H
    Yoshinaga, S
    Ishizawa, T
    Miyake, A
    Obata, M
    Nagaya, S
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 893 - 900