Imaging transverse flow velocity using spectral bandwidth of the Doppler frequency shift in phase-resolved ODT

被引:1
|
作者
Ren, HW [1 ]
Chen, ZP [1 ]
Brecke, KM [1 ]
Ding, ZH [1 ]
Zhao, YH [1 ]
Nelson, JS [1 ]
机构
[1] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
关键词
phase-resolved optical Doppler tomography; Doppler bandwidth; transverse flow;
D O I
10.1117/12.491304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Doppler bandwidth extracted from the standard deviation of the frequency shift in phase-resolved optical Doppler tomography (ODT) is used to image the velocity component transverse to the probing beam. Using a simple geometric optics model, the linear dependence of the Doppler bandwidth on flow velocity is theoretically derived and it is found that the effective numerical aperture (NA) of the optical objective determines the slope of this dependence. Above a certain threshold flow velocity, this linear relationship is in good agreement with experimental data. In the case where the angle between the probing beam and flow direction is within 15 degree to the perpendicular, the Doppler frequency shift is very sensitive to angle position while the Doppler bandwidth is insensitive to flow direction. Linear dependence of the flow velocity on the Doppler bandwidth allows accurate measurement of flow velocity without precise determination of flow direction. In addition, it also extends the dynamic range of the average frequency shift mapping method used in the phase-resolved ODT.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [31] Correction of Phase-error for Phase-resolved k-clocked Optical Frequency Domain Imaging
    Mo, Jianhua
    Li, Jianan
    de Boer, Johannes F.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [32] Spatial Mapping of Tracheal Ciliary Beat Frequency Using Real Time Phase-Resolved Doppler Spectrally Encoded Interferometric Microscopy
    He, Youmin
    Jing, Joseph C.
    Qu, Yueqiao
    Wong, Brian J.
    Chen, Zhongping
    ACS PHOTONICS, 2020, 7 (01) : 128 - 134
  • [33] Direct Blood Flow Measurements in a Free RPE-Choroid Graft with Phase-Resolved Doppler OCT
    van Zeeburg, Elsbeth J. T.
    Braaf, Boy
    Cereda, Matteo G.
    van Meurs, Jan C.
    de Boer, Johannes F.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2015, 4 (01): : 1 - 9
  • [34] Analysis of in vitro and in vivo bidirectional flow velocities by phase-resolved Doppler Fourier-domain OCT
    Walther, Julia
    Mueller, Gregor
    Morawietz, Henning
    Koch, Edmund
    SENSORS AND ACTUATORS A-PHYSICAL, 2009, 156 (01) : 14 - 21
  • [35] Using frequency hypsography to deduce Doppler frequency shift and phase path
    Chen, Jixiang
    2007 5th International Conference on Microwave and Millimeter Wave Technology Proceedings, 2007, : 478 - 480
  • [36] Relation of joint spectral and time domain optical coherence tomography (jS']jSTdOCT) and phase-resolved Doppler OCT
    Walther, Julia
    Koch, Edmund
    OPTICS EXPRESS, 2014, 22 (19): : 23129 - 23146
  • [37] Monitoring laser treatment of port wine stains using phase-resolved optical Doppler tomography
    Zhao, YH
    Chen, ZP
    Saxer, CE
    de Boer, JF
    Majaron, B
    Verkruysse, W
    Nelson, JS
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 237 - 242
  • [38] Transverse motion as a source of noise and reduced correlation of the Doppler phase shift in spectral domain OCT
    Walther, Julia
    Koch, Edmund
    OPTICS EXPRESS, 2009, 17 (22): : 19698 - 19713
  • [39] Transverse flow measurement using photoacoustic Doppler bandwidth broadening: phantom and in vivo studies
    Yao, Junjie
    Maslov, Konstantin I.
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [40] Improved transverse flow estimation using differential maximum Doppler frequency
    Shen, Che-Chou
    Chou, Ching-Han
    Wang, Yu-Chun