Comparison between optical coherence tomography and intravascular ultrasound in detecting neointimal healing patterns after stent implantation

被引:4
|
作者
Kochman, Janusz [1 ]
Pietrasik, Arkadiusz [1 ]
Rdzanak, Adam [1 ]
Jakala, Jacek [2 ]
Zasada, Wojciech [2 ]
Scibisz, Anna [1 ]
Koltowski, Lukasz [1 ]
Proniewska, Klaudia [2 ]
Pociask, Elzbieta [2 ]
Legutko, Jacek [3 ]
机构
[1] Med Univ Warsaw, Dept Cardiol 1, PL-02091 Warsaw, Poland
[2] Krakow Cardiovasc Res Inst, Krakow, Poland
[3] Jagiellonian Univ, Dept Intervent Cardiol, Krakow, Poland
关键词
angiography; IVUS; OCT; in-stent restenosis; neointima; CORONARY-ARTERIES; CLINICAL-APPLICATIONS; BARE-METAL; COVERAGE; DOCUMENT; VIVO; TERMINOLOGY; ACQUISITION; METHODOLOGY;
D O I
10.5603/KP.a2013.0317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The amount of data comparing intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for the detection of stent coverage in clinical settings is limited. Aim: To make a qualitative and quantitative assessment of the vascular healing patterns in patients after stent implantations visualised by both IVUS and OCT. Methods: Images were obtained in patients with clinical symptoms of angina, who had had a bare metal stent implanted in the previous 12 months. Angiography, IVUS and OCT were performed in 14 coronary arteries. Measurements of stent, lumen and neo-intima areas and dimensions were performed in stented regions and in both 10 mm references. IVUS, OCT, and angiographic data were compared in matched regions. Off-line analyses were performed by an independent core lab. Results: 14 stents were imaged without any procedural complications. The nominal stent length was 28 +/- 4.5 mm. OCT was the most accurate technique for assessing stent length (28.12 +/- 6.8 mm), while QCA underestimated length due to foreshortening (22.16 +/- 6.39 mm) and IVUS was vulnerable to random error due to discontinuous pullbacks and vessel movements (24.21 +/- 7.90 mm). Minimum lumen area (MLA) and minimum lumen diameter (MLD) in reference sites were comparable in IVUS and OCT, whereas there were significant differences between these two modalities for MLA (3.30 +/- 1.49 vs. 2.19 +/- 1.30 mm(2), p = 0.0046) and for MLD (2.42 +/- 0.51 vs. 1.58 +/- 0.56 mm(2), p = 0.0023) in stented segments. There was a slight overestimation of lumen volume (130.18 +/- 70.61 vs. 117.82 +/- 67.02 mm(3), p = 0.7256), a marked overestimation of stent volume (179.29 +/- 97.58 vs. 226.46 +/- 108.76 mm(3), p = 0.0544) and a statistically significant difference in the neointima volume (49.11 +/- 39.70 vs. 108.64 +/- 43.77 mm(3), p = 0.0060) by IVUS compared to OCT. Mean neointima burden in IVUS was much smaller than in OCT (20.79 +/- 14.27% vs. 58.16 +/- 18.25%, p = 0.0033). Conclusions: OCT can precisely quantify struts coverage and is more accurate than IVUS in the assessment of vascular healing in patients after stent implantation.
引用
收藏
页码:534 / 540
页数:7
相关论文
共 50 条
  • [31] Analysis of neointimal coverage after silolimus-eluting stent implantation using optical coherence tomography
    Ikuta, S.
    Iwanaga, Y.
    Nakauchi, Y.
    Yamaji, K.
    Kobayashi, N.
    Yabushita, H.
    Hayashi, T.
    Miyazaki, S.
    EUROPEAN HEART JOURNAL, 2010, 31 : 366 - 367
  • [32] Longitudinal neointimal distribution after drug-eluting stent implantation: an optical coherence tomography study
    Otsuki, S.
    Brugaletta, S.
    Shiratori, Y.
    Scalone, G.
    Gomez-Monterrosas, O.
    Romero-Villafane, S.
    Freixa, X.
    Martin-Yuste, V.
    Masotti, M.
    Sabate, M.
    EUROPEAN HEART JOURNAL, 2015, 36 : 490 - 490
  • [33] STENT DESIGN AFFECTS NEOINTIMAL GROWTH PATTERN IN BIFURCATION LESION AFTER STENT IMPLANTATION: OPTICAL COHERENCE TOMOGRAPHY STUDY
    Yoshimura, Takahiro
    Nishino, Masami
    Okamoto, Naotaka
    Tanaka, Akihiro
    Kikuchi, Atsushi
    Masaki, Takeshi
    Mori, Naoki
    Nakamura, Daisuke
    Lee, Yasuharu
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Morita, Hisaki
    Tanouchi, Jun
    Yamada, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1752 - E1752
  • [34] Quantitative and qualitative image comparison between intravascular ultrasound and optical coherence tomography
    Miele, NJ
    Manfrini, O
    Sharaf, BL
    McNamara, E
    Johnson, LL
    Williams, DO
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 60A - 60A
  • [35] Relationship between stent apposition pattern and neointimal coverage after sirolimus-eluting stent implantation: Analysis by optical coherence tomography imaging
    Terashima, M
    Ito, T
    Katoh, O
    Malsubara, T
    Tsuchikane, E
    Ehara, M
    Kinoshita, Y
    Suzuki, T
    Takeda, Y
    Nasu, K
    Surmely, JF
    Tanaka, N
    Murata, A
    Suzuki, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 13B - 13B
  • [36] The relationship between peri-stent contrast staining and positive remodeling after sirolimus-eluting stent implantation assessing with intravascular ultrasound and optical coherence tomography
    Shirasaki, N.
    Tada, T.
    Kadota, K.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2013, 34 : 703 - 703
  • [37] Coronary Stent Intussusception After Intravascular Ultrasound Catheter Removal Optical Coherence Tomography Finding
    Yamaguchi, Hiroshi
    Takaoka, Junichiro
    Miyamura, Akihiro
    Atsuchi, Nobuhiko
    Atsuchi, Yoshihiko
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (06) : 690 - 691
  • [38] Comparison of neointimal coverage of sirolimus-eluting stent and zotarolimus-eluting stent using optical coherence tomography at 9 months after implantation
    Kim, J. -S.
    Kim, J. -S.
    Ko, Y. -G.
    Choi, D.
    Jang, Y.
    Chung, N.
    Shim, W. -H.
    Cho, S. -Y.
    EUROPEAN HEART JOURNAL, 2008, 29 : 147 - 147
  • [39] Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation
    Xie, Yong
    Takano, Masamichi
    Murakami, Daisuke
    Yamamoto, Masanori
    Okamatsu, Kentaro
    Inami, Shigenobu
    Seimiya, Koji
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (01): : 27 - 31
  • [40] Comparison of Neointimal Coverage of Sirolimus-Eluting Stent and Paclitaxel-Eluting stent using Optical Coherence Tomography at 9 Months After Implantation
    Kim, Jin-Sun
    Kim, Jung-Sun
    Park, Sang Min
    Kim, Won-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 32I - 32I