Comparison between optical coherence tomography and intravascular ultrasound in detecting neointimal healing patterns after stent implantation

被引:4
|
作者
Kochman, Janusz [1 ]
Pietrasik, Arkadiusz [1 ]
Rdzanak, Adam [1 ]
Jakala, Jacek [2 ]
Zasada, Wojciech [2 ]
Scibisz, Anna [1 ]
Koltowski, Lukasz [1 ]
Proniewska, Klaudia [2 ]
Pociask, Elzbieta [2 ]
Legutko, Jacek [3 ]
机构
[1] Med Univ Warsaw, Dept Cardiol 1, PL-02091 Warsaw, Poland
[2] Krakow Cardiovasc Res Inst, Krakow, Poland
[3] Jagiellonian Univ, Dept Intervent Cardiol, Krakow, Poland
关键词
angiography; IVUS; OCT; in-stent restenosis; neointima; CORONARY-ARTERIES; CLINICAL-APPLICATIONS; BARE-METAL; COVERAGE; DOCUMENT; VIVO; TERMINOLOGY; ACQUISITION; METHODOLOGY;
D O I
10.5603/KP.a2013.0317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The amount of data comparing intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for the detection of stent coverage in clinical settings is limited. Aim: To make a qualitative and quantitative assessment of the vascular healing patterns in patients after stent implantations visualised by both IVUS and OCT. Methods: Images were obtained in patients with clinical symptoms of angina, who had had a bare metal stent implanted in the previous 12 months. Angiography, IVUS and OCT were performed in 14 coronary arteries. Measurements of stent, lumen and neo-intima areas and dimensions were performed in stented regions and in both 10 mm references. IVUS, OCT, and angiographic data were compared in matched regions. Off-line analyses were performed by an independent core lab. Results: 14 stents were imaged without any procedural complications. The nominal stent length was 28 +/- 4.5 mm. OCT was the most accurate technique for assessing stent length (28.12 +/- 6.8 mm), while QCA underestimated length due to foreshortening (22.16 +/- 6.39 mm) and IVUS was vulnerable to random error due to discontinuous pullbacks and vessel movements (24.21 +/- 7.90 mm). Minimum lumen area (MLA) and minimum lumen diameter (MLD) in reference sites were comparable in IVUS and OCT, whereas there were significant differences between these two modalities for MLA (3.30 +/- 1.49 vs. 2.19 +/- 1.30 mm(2), p = 0.0046) and for MLD (2.42 +/- 0.51 vs. 1.58 +/- 0.56 mm(2), p = 0.0023) in stented segments. There was a slight overestimation of lumen volume (130.18 +/- 70.61 vs. 117.82 +/- 67.02 mm(3), p = 0.7256), a marked overestimation of stent volume (179.29 +/- 97.58 vs. 226.46 +/- 108.76 mm(3), p = 0.0544) and a statistically significant difference in the neointima volume (49.11 +/- 39.70 vs. 108.64 +/- 43.77 mm(3), p = 0.0060) by IVUS compared to OCT. Mean neointima burden in IVUS was much smaller than in OCT (20.79 +/- 14.27% vs. 58.16 +/- 18.25%, p = 0.0033). Conclusions: OCT can precisely quantify struts coverage and is more accurate than IVUS in the assessment of vascular healing in patients after stent implantation.
引用
下载
收藏
页码:534 / 540
页数:7
相关论文
共 50 条
  • [21] Visualization of tissue prolapse between coronary stent struts by optical coherence tomography - Comparison with intravascular ultrasound
    Jang, IK
    Tearney, G
    Bouma, B
    CIRCULATION, 2001, 104 (22) : 2754 - 2754
  • [22] Abluminal Neointimal Healing by Optical Coherence Tomography Assessment After Drug-Eluting Stent Implantation on Organized Recanalized Thrombus
    Camacho Freire, Santiago Jesus
    Limpo, Bruno
    Leon Jimenez, Javier
    Gomez Menchero, Antonio Enrique
    Roa Garrido, Jessica
    Cardenal Piris, Rosa
    Diaz Fernandez, Jose Francisco
    JOURNAL OF INVASIVE CARDIOLOGY, 2017, 29 (11): : E161 - E162
  • [23] A Case of In-Stent Neointimal Plaque Rupture 10 Years After Bare Metal Stent Implantation: Intravascular Ultrasound and Optical Coherence Tomographic Findings
    Yoon, Hyuck-Jun
    Hur, Seung-Ho
    Kim, Shin-Keun
    Kim, Hyungseop
    Park, Hyoung-Seob
    Cho, Yun-Kyeong
    Nam, Chang-Wook
    Kim, Yoon-Nyun
    Kim, Kwon-Bae
    KOREAN CIRCULATION JOURNAL, 2011, 41 (11) : 671 - 673
  • [24] Healing course of coronary edge dissections after primary percutaneous coronary intervention with stent implantation assessed by intravascular ultrasound with iMap and optical coherence tomography
    Hougaard, M.
    Hansen, H. S.
    Thayssen, P.
    Junker, A.
    Antonsen, L.
    Jensen, L. O.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1020 - 1021
  • [25] Optical Coherence Tomography Illuminates Intravascular Ultrasound-Invisible Sac-Like Structure After Stent Implantation
    Komaki, Soichi
    Ishii, Masanobu
    Kurogi, Kazumasa
    Yamamoto, Nobuyasu
    CIRCULATION JOURNAL, 2021, 85 (07) : 1099 - 1099
  • [26] DIFFERENCE BETWEEN CORONARY ANGIOSCOPY AND OPTICAL COHERENCE TOMOGRAPHY IN THE ASSESSMENT OF NEOINTIMAL FINDINGS AT FOLLOW UP AFTER STENT IMPLANTATION
    Taichi, Nakamura
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1425 - 1425
  • [27] CORRELATION BETWEEN DEGREE OF NEOINTIMAL HYPERPLASIA AND INCIDENCE AND CHARACTERISTICS OF NEOATHEROSCLEROSIS AFTER STENT IMPLANTATION: AN OPTICAL COHERENCE TOMOGRAPHY STUDY
    Vergallo, Rocco
    Yonetsu, Taishi
    Lee, Stephen
    Uemura, Shiro
    Kato, Koji
    Jia, Haibo
    Abtahian, Farhad
    Tian, Jinwei
    Hu, Sining
    Aguirre, Aaron
    McNulty, Iris
    Lee, Hang
    Zhang, Shaosong
    Yu, Bo
    Porto, Italo
    Biasucci, Luigi
    Crea, Filippo
    Jang, Ik-Kyung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1800 - E1800
  • [28] Prediction of late neointimal regression after drug-eluting stent implantation by optical coherence tomography
    Okura, H.
    Fukuhara, K.
    Yamada, R.
    Kume, T.
    Neishi, Y.
    Yoshida, K.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1145 - 1145
  • [29] Impact of Frequency-Domain Optical Coherence Tomography Guidance for Optimal Coronary Stent Implantation in Comparison With Intravascular Ultrasound Guidance
    Habara, Maoto
    Nasu, Kenya
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Yokota, Daisuke
    Ko, Euihong
    Ito, Tsuyoshi
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Ito, Tatsuya
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Asakura, Keiko
    Asakura, Yasushi
    Katoh, Osamu
    Suzuki, Takahiko
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) : 193 - 201
  • [30] Dynamic neointimal pattern after drug-eluting stent implantation defined by optical coherence tomography
    Yamamoto, Erika
    Xing, Lei
    Higuma, Takumi
    Minami, Yoshiyasu
    Bryniarski, Krzysztof
    Zanchin, Thomas
    Wang, Zhao
    Aguirre, Aaron D.
    Lee, Hang
    Jang, Ik-Kyung
    CORONARY ARTERY DISEASE, 2017, 28 (07) : 557 - 563